Description
1. Introduction
The 350 ml Endoscopic Retrieval Bag (SKU WZSRB-B-100) is the benchmark disposable surgical accessory for the safe retrieval of specimens and tissue samples in laparoscopic and endoscopic procedures. Its combination of transparent medical-grade polymer and a mouth with Ni-Ti memory alloy ensures reliable tissue containment during extraction through a small incision, protecting the patient against the risk of tumour dissemination, metastasis and heterotopic growth. A device designed for the modern operating theatre: single-use hygiene, clinical safety and ease of handling for the surgical team.
2. Technical explanation of the equipment
The device mainly consists of an ergonomic actuation handle and a retrieval endobag. The bag is made of transparent, soft medical-grade polymer, with high strength and a generous opening mouth whose rim incorporates a Ni-Ti (nickel-titanium) memory alloy: this feature keeps the mouth open during the manoeuvre, facilitating specimen introduction without additional effort. Once inside, the tissue is automatically secured within the bag, preventing spillage during the extraction path. The ergonomic handle design allows comfortable pushing and pulling, and the assembly deploys smoothly through the working channel of the laparoscopic trocar (standard market use: 10–12 mm trocars; confirm deployment before the procedure). In addition, the removable sheath tube facilitates the retrieval of larger samples, meeting various surgical demands. As a single-use device, the risk of cross-contamination between patients is eliminated and traceability in the operating theatre is guaranteed.
3. Technical Specifications
The main technical features of the 350 ml endoscopic retrieval bag are detailed below:
| Characteristic | Specification |
|---|---|
| Capacity | 350 ml |
| Short shaft | 103 mm |
| Long shaft | 115 mm |
| Bag material | Transparent, soft medical-grade polymer |
| Mouth coating | Ni-Ti memory alloy (nickel-titanium) |
| Configuration | Ergonomic handle + endobag with self-opening mouth and removable sheath tube |
| Type of use | Disposable, single-use |
| Working channel (standard use) | 10–12 mm trocars (confirm deployment before the procedure) |
| SKU Cahnos | WZSRB-B-100 |
WZSRB range of endoscopic extraction bags (family references):
| SKU | Capacity | Dimensions |
|---|---|---|
| WZSRB-A-40 | 35 ml | Diameter 40 mm |
| WZSRB-A-60 | 80 ml | Diameter 60 mm |
| WZSRB-B-80 | 250 ml | Short shaft 82 mm / long shaft 92 mm |
| WZSRB-B-100 | 350 ml | Short shaft 103 mm / long shaft 115 mm |
| WZSRB-B-130 | 1000 ml | Short shaft 118 mm / long shaft 154 mm |
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing this reference with the official codes of other brands; consult the technical department before using this information in a tender. At product category level, this 350 ml bag is comparable by category, not interchangeable 1:1, with the following specimen retrieval systems on the market:
| Manufacturer / Brand | Family / Model | Code / Reference | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Ethicon (J&J MedTech) | ENDOPOUCH RETRIEVER™ | POUCH (224 ml) | Comparable by category | Transparent self-opening polyurethane bag with support arms; lower volume (224 ml) and format for 10 mm trocar. |
| Conmed / Medical Disposables | Anchor Tissue Retrieval / MD EndoGuidance | MDSR10-200 / MDSR10-400 | Comparable by category | Self-expanding retrieval bag systems of 200–400 ml; strong nylon or material depending on model; different mouth geometries and materials. |
| Medline (Med-Lap range) | Specimen Retrieval Bag | 100200 (200 ml) / 100400 (400 ml) | Comparable by category | Latex-free polyurethane with self-opening wire; opening and material different from Ni-Ti alloy; similar but not identical capacities. |
| Medtronic | Endo Catch II (Specimen Retrieval System) | 173049 | Comparable by category | 1000 ml polyurethane bag with continuous metal ring; insertion through 15 mm cannula; mouth geometry and material different from Ni-Ti alloy. |
| Applied Medical | Inzii™ Retrieval System | Own range | Pending confirmation | System with opening guide; verify codes, dimensions and material in the manufacturer’s official datasheet. |
| Teleflex / Weck | MemoBag® | Own range | Pending confirmation | Preloaded bag with simple deployment; confirm capacity, material and trocar compatibility in the official datasheet. |
5. Selection tips and variants of interest
Select the bag capacity according to the expected specimen volume: for small samples, the 35 ml (WZSRB-A-40) or 80 ml (WZSRB-A-60) versions; for moderate procedures, the 250 ml (WZSRB-B-80) or this 350 ml one; and for bulky extractions —large myomas, spleens, kidneys or extensive surgical pieces—, the 1000 ml version (WZSRB-B-130), the largest capacity in the range. Always verify the compatibility of the deployment diameter with the working channel of your laparoscopic tower trocar (standard market use: 10–12 mm trocars; confirm deployment before the procedure). For larger specimens, the range with removable sheath tube facilitates the retrieval of large samples. As a single-use device, calculate stock according to procedure volume and consider the family variants to cover the full range of surgeries in the general surgery, gynaecology and digestive system department. For volume purchase conditions or hospital budgets, consult your technical-commercial advisor at Cahnos.