Description
Saver Spiner Kyphoplasty Kit — Vertebral Augmentation Balloon System
Direct or traditional access · Single or double configuration · Fluoroscopic/CT guidance · CE marking
1. Introduction
The Saver Spiner Kyphoplasty Kit is a vertebral augmentation balloon system designed for the minimally invasive treatment of vertebral pain resulting from recent vertebral fractures. Thanks to its low-pressure dilatation balloon, it allows restoration of the height of the fractured vertebral body and creation of a controlled cavity for subsequent injection of bone cement, with predictable results and rapid functional recovery of the patient.
Available in two access approaches (direct and traditional) and in single or double access configurations, this kit adapts to each surgeon’s preferred technique and to the anatomical requirements of each vertebral level, including the upper cervical and upper thoracic segments.
2. Technical explanation of the procedure
Balloon-assisted kyphoplasty (vertebral augmentation balloon) restores vertebral height and reduces the fracture before biomaterial injection, minimising cement leakage. The procedure is performed in four steps:
- Percutaneous insertion of the balloon into the fractured vertebral body through the access needle (direct) or via introducer needle and Kirschner wires (traditional).
- Gradual balloon inflation to reduce the fracture, compact the cancellous bone and restore vertebral height with low inflation pressure, reducing the risk of extravertebral migration of PMMA.
- Balloon deflation and removal, leaving a controlled cavity within the vertebral body.
- Cavity filling with the chosen bone cement (biomaterial) using the included injection cannulas and syringes.
The use of low inflation pressures improves procedure safety, ensures controlled cement placement and reduces the likelihood of extravasation. Image guidance is performed using fluoroscopy, or CT in selected cases of upper cervical or upper thoracic vertebrae. It can be performed under local or general anaesthesia.
3. Technical Specifications
| Description | Vertebral augmentation balloon system (kyphoplasty kit) |
| Function | Restoration of vertebral body height and creation of a controlled cavity for subsequent bone cement injection |
| Access types | Direct access (Direct Access) and traditional access (Traditional Access) |
| Configurations | Single access (single) and double access (double) |
| Image guidance | Fluoroscopy; computed tomography (CT) in selected cases of upper cervical or upper thoracic vertebrae |
| Anaesthesia | Local or general |
| Inflation pressure | Low balloon inflation pressure, reducing the risk of extravertebral migration of PMMA |
| Available sizes | 08G and 11G |
| Needle length | 100 mm |
| Balloon diameters | 10 mm, 15 mm and 20 mm |
| CE marking | Yes |
| Use | Single-use — do not reuse |
Kit composition
Direct Access Kit (Direct Access)
- 1 Direct Access Needle (2 units in double access configuration)
- 1 Drill
- 1 Dilatation Balloon Catheter (2 units in double access)
- 3 Cement Injection Cannulas (6 units in double access)
- 3 Syringes (6 units in double access)
- 1 Inflation Device (2 units in double access)
Traditional Access Kit (Traditional Access)
- 1 Introducer Needle (2 units in double access)
- 2 Kirschner Wires (4 units in double access)
- 1 Dilator Needle (2 units in double access)
- 1 Drill
- 1 Dilatation Balloon Catheter (2 units in double access)
- 3 Cement Injection Cannulas (6 units in double access)
- 3 Syringes (6 units in double access)
- 1 Inflation Device (2 units in double access)
References and ordering information
Kyphoplasty Kit, Traditional Access
| Code (Single) | Code (Double) | Description |
|---|---|---|
| 495681001 | 495781001 | 08G x 100 mm, Balloon 10 mm |
| 495681002 | 495781002 | 08G x 100 mm, Balloon 15 mm |
| 495681003 | 495781003 | 08G x 100 mm, Balloon 20 mm |
| 495681011 | 495781011 | 08G x 100 mm, Balloon 10 mm, Hollow Drill |
| 495681012 | 495781012 | 08G x 100 mm, Balloon 15 mm, Hollow Drill |
| 495681013 | 495781013 | 08G x 100 mm, Balloon 20 mm, Hollow Drill |
| 495610001 | 495710001 | 11G x 100 mm, Balloon 10 mm |
| 495610002 | 495710002 | 11G x 100 mm, Balloon 15 mm |
| 495610003 | 495710003 | 11G x 100 mm, Balloon 20 mm |
| 495610011 | 495710011 | 11G x 100 mm, Balloon 10 mm, Hollow Drill |
| 495610012 | 495710012 | 11G x 100 mm, Balloon 15 mm, Hollow Drill |
| 495610013 | 495710013 | 11G x 100 mm, Balloon 20 mm, Hollow Drill |
Presentation: box of 1 unit.
Kyphoplasty Kit, Direct Access
| Code (Single) | Code (Double) | Description |
|---|---|---|
| 495381011 | 495481011 | 08G x 100 mm, Balloon 10 mm |
| 495381012 | 495481012 | 08G x 100 mm, Balloon 15 mm |
| 495381013 | 495481013 | 08G x 100 mm, Balloon 20 mm |
| 495311011 | 495411011 | 11G x 100 mm, Balloon 10 mm |
| 495311012 | 495411012 | 11G x 100 mm, Balloon 15 mm |
| 495311013 | 495411013 | 11G x 100 mm, Balloon 20 mm |
Presentation: box of 1 unit.
Individual components
| Code | Description |
|---|---|
| 495010810 | 08G x 100 mm, Access Needle |
| 495011110 | 11G x 100 mm, Access Needle |
| 495020810 | 08G x 100 mm, Dilator Needle |
| 495021110 | 11G x 100 mm, Dilator Needle |
| 495030810 | 08G x 100 mm, Drill |
| 495031110 | 11G x 100 mm, Drill |
| 495930810 | 08G x 100 mm, Hollow Drill |
| 495931110 | 11G x 100 mm, Hollow Drill |
| 495040810 | 08G x 100 mm, Cement Injection Cannula |
| 495041110 | 11G x 100 mm, Cement Injection Cannula |
| 495100810 | 08G x 100 mm, Dilatation Balloon Catheter 10 mm |
| 495100815 | 08G x 100 mm, Dilatation Balloon Catheter 15 mm |
| 495100820 | 08G x 100 mm, Dilatation Balloon Catheter 20 mm |
| 495100110 | 11G x 100 mm, Dilatation Balloon Catheter 10 mm |
| 495100115 | 11G x 100 mm, Dilatation Balloon Catheter 15 mm |
| 495100120 | 11G x 100 mm, Dilatation Balloon Catheter 20 mm |
| 495050000 | Syringe |
| 495060000 | Kirschner Wire |
| 495080001 | Inflation Device |
Presentation: box of 1 unit.
Regulations and documentation
| CE marking | Yes |
| Use | Single-use — do not reuse |
| Intended use | Exclusive to qualified healthcare professionals or physicians with appropriate training and experience |
4. Equivalences and Cross-References
This vertebral augmentation balloon system falls within the family of balloon-assisted kyphoplasty devices used to restore vertebral height before cementation. Its technical concept (low-pressure dilatation balloon + access kit + bone cement injection) is comparable to that of kyphoplasty balloon systems from leading spinal surgery companies, such as the vertebral augmentation balloons for vertebroplasty/kyphoplasty available on the European market.
The kit is compatible with the usual workflow of injectable PMMA bone cements of low and high viscosity, as well as with vertebral filling biomaterials (injectable bone substitutes). For selection of the equivalent reference, attention must be paid to the access type (direct or traditional), the gauge (08G or 11G) and the balloon diameter (10, 15 or 20 mm), criteria that coincide with those used by other manufacturers of kyphoplasty kits.
The range is completed with the individual components (needles, drills, cannulas, balloon catheters, syringes, Kirschner wires and inflation device), which facilitates the replacement of consumables and the adaptation of the kit to the preferred technique.
5. Selection tips and variants of interest
- Direct access vs. traditional: direct access streamlines the procedure by reducing the number of instrumentation steps; traditional access, with introducer needle, dilator needle and Kirschner wires, is the reference option in conventional techniques and in anatomies requiring greater control of the approach route.
- Single or double configuration: the double-access configuration (double balloon) is indicated in central fractures or severe collapse, allowing a symmetrical restoration of vertebral height; double-access references duplicate the kit components (codes 4957xx, 4954xx).
- Gauge: the 08G gauge is recommended for a finer profile and less trauma to the tract; the 11G gauge offers greater instrument robustness and is common in larger vertebral bodies.
- Balloon diameter: select a 10 mm balloon for small or cervical vertebrae, 15 mm as the standard option for thoracic vertebrae and 20 mm for large vertebral bodies (thoracolumbar and lumbar segments).
- Hollow drill: versions with hollow drill (codes …011, …012 and …013) facilitate the creation of the tract and preparation of the canal before balloon inflation.
- Always verify the compatibility of the selected bone cement with the gauge of the injection cannulas (08G or 11G) of the kit.
Presentation: box of 1 unit. Single-use product, do not reuse.





Reviews