Description
1. Commercial Introduction
The paediatric Thomas Holder (ref. 05-1651) is an endotracheal tube holder designed to protect and stabilise the airway of the paediatric patient during intubation. This blocking system ensures firm fixation of the tube, preventing displacement and injury to oral tissues. A practical and safe solution for emergency services, paediatrics, intensive care units and medical transport. For large orders you can request a quote.
2. Technical explanation of the equipment
The Thomas Holder fixator acts as an endotracheal tube blocking system (safety endotracheal tubes blocking system). It incorporates a screw fixation system that integrates an anti-squeeze protection surface, called no-lockjaw, whose function is twofold: on the one hand it protects the patient’s teeth and gums and, on the other, it prevents crushing or occlusion of the endotracheal tube during tightening. This design allows the tube to be fixed safely and stably without resorting to surgical tape, plaster or other dressings, which speeds up the procedure, keeps the perioral facial area clean and facilitates inspection and cleaning of the oral cavity without dismantling the fixation. It is especially indicated for paediatric patients, where reduced tube mobility and protection of oral tissues are critical.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Product | Paediatric endotracheal tube holder – Thomas Holder |
| Manufacturer | Boscarol |
| Manufacturer reference | 05-1651 |
| Reference Cahnos | BRL05-1651 |
| Main function | Endotracheal tube blocking system (safety endotracheal tubes blocking system) |
| Fixation system | Screw mechanism |
| Protection surface | Anti-squeeze (no-lockjaw): protects teeth and gums and prevents crushing of the endotracheal tube |
| Additional fixation | Does not require the use of plaster or surgical tape |
| Target population | Paediatric |
| Category | Respiration and emergency care / Resuscitation |
4. Equivalences and Cross-References
The original manufacturer reference is 05-1651, distributed by Cahnos as BRL05-1651 within the resuscitation material range. No validated 1:1 equivalence table with other manufacturers is available from reliable sources for this paediatric holder: endotracheal tube anchoring systems (straps, bite holders, mouth guards) are specific to each manufacturer and must always be checked against the official technical data sheet before any replacement. To confirm compatibility with your paediatric intubation protocol, contact the technical-commercial department of Cahnos.
5. Selection tips and variants of interest
Verify that the reference corresponds to the paediatric version of the Thomas Holder (05-1651) before incorporating it into your airway equipment: the size of the holder must be appropriate for the diameter of the endotracheal tube and the oral anatomy of the paediatric patient. Confirm the progressive tightening of the screw mechanism until a firm hold is achieved without occluding the tube, relying on the anti-squeeze surface that protects the tissues. Remember that this system avoids the use of plaster, which facilitates hygiene and maintenance of the oral cavity in prolonged intubations. For institutional orders, tenders and purchasing centres, consult the Cahnos team.





Reviews
There are no reviews yet.