We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Dixion AEROS 4600 Plus ICU Ventilator | Invasive and non-invasive (NIV) with 12.1″ touchscreen for intensive care and emergency

Price on request

Heavy / bulky product. Shipping is neither free nor included in the price: it depends on the destination, Cahnos subsidises part of it and we will confirm the cost separately after your order. If you need it before buying, please contact us.

The Dixion AEROS 4600 Plus ventilator combines invasive ICU ventilation and non-invasive ventilation (NIV) in a single device, ideal for intensive care, emergencies and intrahospital transport. Its automatic leak detection maintains precise tidal volume control and its advanced triggering technique avoids false triggers, optimising patient-ventilator synchrony. It incorporates a detachable 12.1″ TFT touchscreen, multiparametric monitoring, VCV, PCV, SIMV, SPONT/CPAP+PSV, PRVC and BIVENT/APRV modes, an autoclavable heated metal exhalation valve, high-capacity battery and mobility without an air compressor. Reference: AEROS4600.

International shipping. Import duties and taxes are payable by the recipient.

Reference
AEROS4600

You will also find it in

Description

1. Product Presentation

The AEROS 4600 Plus from Dixion is the dual solution that your intensive care, emergency or critical care department needs: a complete ICU invasive ventilator and, at the same time, a flexible and effective non-invasive ventilator. In a single platform, it combines all the functions of an ICU ventilator with the advantages of non-invasive ventilation, which reduces intubation rates, shortens length of stay, improves patient comfort and reduces the risk of cross-infection. Distributed by Cahnos, it is the ideal choice for equipment supply projects, ventilator fleet renewal and expansion of critical care beds, with a performance/mobility ratio that is hard to match.

2. Technical explanation of the equipment

The AEROS 4600 Plus predefines the patient’s height and PCI (inspiratory control parameter), relieving the clinician’s workload in the initial phase of treatment. Its leak compensation system maintains precise tidal volume control by automatically adjusting the compensation dose, while the advanced trigger technique improves trigger sensitivity and prevents false triggering, reducing respiratory effort. The automatic leak detection adjusts compensation efficiently, especially critical in NIV with face mask, and its multiparametric behaviour listens and automatically adapts to each patient’s breathing pattern.

The device operates on medical gas (air and oxygen) without an internal air compressor, incorporates a large-capacity battery that enables in-hospital mobility (transfers between units, emergency care and transport within the hospital) and can be configured on a trolley, bed mount or column/pendulum arm. Its heated metal exhalation valve is autoclavable and its integrated flow sensor has a non-consumable design, which reduces the cost per patient. The 12.1″ colour TFT touchscreen is detachable and allows continuous multiparametric monitoring.

3. Technical Specifications

Data verified against the manufacturer’s official documentation (user manual UM04-06 Aeros 4600 and Dixion product data sheet).

General data

Parameter Specification
Manufacturer DIXION (Vertrieb medizinischer Geräte GmbH, Germany)
Model AEROS 4600 Plus
Reference / SKU AEROS4600
Set type Intensive care ventilator, invasive and non-invasive (dual solution)
Patient type Adults and paediatrics (from 20 ml tidal volume)
Areas of use ICU, emergency department, emergency care, in-hospital transport
Display 12.1″ colour TFT, touchscreen and detachable
Operating gas Medical air and oxygen, without internal air compressor
Power / mobility Large-capacity battery, in-hospital mobility
Configuration Trolley, bed mount or column/pendulum arm

Ventilation modes

Type Modes
Controlled VCV (A/C), PCV (A/C)
Synchronised SIMV with pressure support (PSV)
Spontaneous SPONT / CPAP with pressure support
Advanced PRVC (pressure-regulated volume control), BIVENT/APRV
Non-invasive (NIV) Non-invasive ventilation with leak compensation

Parameter ranges (official data)

Parameter Range / Specification
Tidal volume (Vt) 20 – 2000 ml
Respiratory rate 1 – 80 rpm
Inspiratory time Adjustable (programmable)
Inspiratory flow Adjustable (programmable)
Inspiratory pressure Adjustable (programmable)
Oxygen concentration (FiO2) Adjustable (programmable)
Leak compensation Yes, automatic with leak detection
Trigger system Advanced technique, prevents false triggering
Exhalation valve Metal, heated and autoclavable
Flow sensor Integrated, non-consumable design
Monitoring Multiparametric (volumes, pressures, FiO2 and curves)

Note: for full details of ranges and alarms, refer to the manufacturer’s official manual UM04-06 Aeros 4600.

4. Equivalences and Cross-References

There is no equivalence table validated by the manufacturer Dixion that cross-references the AEROS 4600 with other brands 1:1; consult the technical department before using in tenders. Within the same AEROS family, the AEROS 4800 (SKU AEROS4800) is the higher ICU evolution with which it shares the configuration platform and most of the parameter ranges and modes; below it, the AEROS 4300 (SKU AEROS4300) and the integrated station AEROS 4300S (SKU AEROS4300S) cover emergency department, resuscitation and transport.

On the market, equipment comparable at category level (not 1:1 interchangeable) is used in the compact ICU ventilator segment with invasive and non-invasive ventilation, battery and intrahospital mobility, such as the Mindray SV300 and the Hamilton Medical HAMILTON-C1; other critical care ventilation manufacturers (Aeonmed, among others) also offer dual platforms. Before any substitution, the professional must check the official datasheets for: tidal volume and frequency range, available invasive and non-invasive modes, type of gas required (with or without compressor), battery autonomy, type of exhalation valve and flow sensor, admitted paediatric population and regulatory classification of the actual device.

5. Selection tips and variants of interest

To choose the most suitable configuration, consider the circuit of use: if you need advanced invasive and non-invasive ventilation with lung protection (PRVC, BIVENT/APRV) for adult and paediatric ICU patients, the AEROS 4800 is the reference option in the family. If your need focuses on a dual device for intensive care and emergencies with a compact profile, battery and intrahospital mobility, the AEROS 4600 is the balanced choice. For emergencies, resuscitation or transport with an integrated station, consult the AEROS 4300 or the AEROS 4300S station with trolley, humidifier, breathing circuit and O2 cylinder support. Always check the availability of medical gas (air and oxygen outlets), the support system (trolley, bed or arm/pendulum) and the electromagnetic compatibility regulations applicable in your facility. Our technical-commercial department will advise you on the selection, commissioning, training and maintenance of the device.

Additional information

Manufacturer

DIXION (Vertrieb medizinischer Geräte GmbH, Germany)

Model

AEROS 4600 Plus

Set type

Intensive care ventilator, invasive and non-invasive (dual solution)

Patient type

Adults and paediatrics (from 20 ml tidal volume)

Ventilation modes

VCV (A/C), PCV (A/C), SIMV+PSV, SPONT/CPAP+PSV, PRVC, BIVENT/APRV, NIV

Display

12.1" colour TFT, touchscreen and detachable

Tidal volume

20-2000 ml

Respiratory rate

1-80 rpm

Leak compensation

Yes, with automatic detection

Trigger system

Advanced technique, prevents false triggering

Exhalation valve

Metal, heated, autoclavable

Flow sensor

Integrated, non-consumable design

Operating gas

Medical air and oxygen, without internal compressor

Battery

Large capacity, in-hospital mobility

Configuration

Trolley, bed mount or column/pendulum arm

Monitoring

Multiparametric (volumes, pressures, FiO2, curves)

Presentation

Unit (electromedical equipment)

Reviews

There are no reviews yet.

Be the first to review “Dixion AEROS 4600 Plus ICU Ventilator | Invasive and non-invasive (NIV) with 12.1″ touchscreen for intensive care and emergency”

Your email address will not be published. Required fields are marked *