Description
1. Complete percutaneous dilation tracheostomy kit
The percutaneous dilation kit Ref. TP90-17 is the complete solution for establishing tracheal access by puncture and progressive dilation in the critically ill adult patient, following the Ciaglia single-dilator technique. It incorporates a reinforced 7 mm tracheostomy tube with adjustable flange and helical anti-kink reinforcement, the configuration indicated for smaller adults or more limited anatomical situations within the reinforced Ciaglia kit family from Cahnos.
All the material required for the procedure is presented in a single sterile, ready-to-use kit: one order, one code and the assurance that the team has all the instruments with full traceability. Preparation time is reduced, the risk of forgetting material is minimised and standardisation of the process is facilitated in ICU, emergency departments and the operating theatre.
2. Technical explanation of the procedure
Percutaneous dilation tracheostomy using the Ciaglia technique is performed by tracheal puncture with an introducer needle, passage of a guidewire and progressive dilation of the stoma with a single 38 Fr conical-profile dilator, which allows the access to be created in a single step. This design minimises tissue trauma compared with open surgical techniques and promotes a faster, safer bedside procedure, without the need to move the critically ill patient.
The reinforced 7 mm tube incorporates a helical coil that prevents collapse and kinking of the airway, particularly relevant in patients with frequent mobilisation, obesity or unfavourable cervical anatomy. The adjustable flange allows the device to be secured to the skin of the neck to suit different anatomies (cervical oedema, variations in neck thickness), while the introducer with locking system and conical tip maintains the tube position during insertion until it is correctly placed in the trachea. The 0.05″ (0.89 mm) nitinol J-tip guidewire is kink-resistant, providing safety and control throughout the procedure, which is usually performed under endoscopic or bronchoscopic guidance. The kit is indicated for standard tracheostomy, cricothyrotomy, coniotomy or laryngotomy in adult patients.
3. Technical specifications and kit contents
Kit contents
| Component | Specification |
|---|---|
| Tracheotomy cannula | Reinforced 7 mm tube with adjustable flange and helical anti-kink reinforcement |
| Dilator | 38 Fr, conical profile for single-step dilation |
| Tube introducer | With locking system and conical tip |
| Guidewire | J-tip nitinol 0.05″ (0.89 mm), kink-resistant |
| Guide catheter | Included for guiding the dilator |
| Scalpel | Safety No. 15 with retractable protection |
| Syringe | 10 ml |
| Introducer needle | 16 G |
| Fixation band | With Velcro closure |
| Table cover | For instruments |
| Lubricating gel | Sterile sachet |
| Sterilisation | Ethylene oxide (ETO), process validated according to EN 11135-1; residuals compliant with ISO 10993-7 |
Technical features of the tube
| Parameter | Value |
|---|---|
| Internal tube diameter | 7.0 mm |
| External tube diameter | 9.5 mm |
| Tube length | 95 mm |
| Tube type | Reinforced, with anti-kink helical reinforcement |
| Flange type | Adjustable, flexible transparent plastic |
| Subglottic suction | No (standard version) |
| Balloon (cuff) | Low pressure |
| Connector | Universal 15 mm (15M) |
| Use | Single-use (sterile) |
| Materials | Latex-free and phthalate-free |
| Classification | Medical device class IIa |
Family of Ciaglia kits with adjustable flange and reinforced tube (TP90-1x series)
| Reference | Tube diameter | Tube type | Flange | Dilator |
|---|---|---|---|---|
| TP90-17 (this product) | 7 mm | Reinforced | Adjustable | 38 Fr |
| TP90-18 | 8 mm | Reinforced | Adjustable | 38 Fr |
| TP90-19 | 9 mm | Reinforced | Adjustable | 38 Fr |
4. Equivalences and Cross-References
The Ciaglia single-dilator technique with a 38 Fr dilator is a widely established standard in percutaneous tracheostomy. Below are listed the best-known market references, classified according to the level of verification achieved by our technical department; none should be treated as an exact 1:1 equivalence:
- Comparable at category level: Cook Medical Ciaglia Blue Rhino G2 (percutaneous single-dilator introducer set, multi-use reference G2-Multi). Same single-step dilation principle and 38 Fr dilator, but it is a set from a different manufacturer with different components and presentation: not interchangeable 1:1.
- Comparable at category level: TRACOE experc (REF 520), dilation kit for percutaneous tracheotomy with nitinol Seldinger guidewire and hydrophilic dilator. Same clinical indication, different component configuration.
- Comparable at category level: single-step percutaneous dilation tracheotomy kits with 38 Fr dilator from other manufacturers in the sector (single-dilator technique).
Within Cahnos’s own catalogue, this kit has no exact equivalent: the 7 mm version with standard tube and adjustable flange (TP90-07) shares the size and flange but differs in tube type (without reinforced coil); the reinforced 7 mm version with fixed flange (TP90-27) differs in flange type, and the 7 mm version with subglottic suction (TP90-37) adds a suction lumen. None of these should be treated as interchangeable in terms of performance.
There is no manufacturer-validated equivalence table that allows this reference to be cross-referenced with specific codes from other suppliers; it is recommended to consult the technical department of Cahnos before using this datasheet in a tendering process or stock replacement.
5. Selection tips and variants of interest
To choose the right kit, assess the tube diameter according to the patient and the clinical indication: the 7 mm variant (TP90-17) is reserved for adults of smaller build or more limited anatomical situations; the 8 mm (TP90-18) is the reference option for adults of medium build, and the 9 mm (TP90-19) for adults of medium-large build or with a need for greater ventilatory flow.
The reinforced tube with helical anti-kinking construction is especially useful when patient mobilisation, risk of cervical compression or the need to maintain airway patency in difficult positions is anticipated. The adjustable flange offers a clear advantage in patients with cervical oedema or variations in neck thickness. If a standard non-reinforced tube is preferred, see the TP90-0x series (TP90-07, TP90-08 and TP90-09); if a fixed flange is required, the TP90-2x series (TP90-27, TP90-28 and TP90-29), and for prolonged mechanical ventilation with prevention of ventilator-associated pneumonia, the subglottic suction versions TP90-37, TP90-38 and TP90-39. All kits in the family are single-use: dispose of them after the procedure as clinical waste in accordance with local regulations.






Reviews