We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Oropharyngeal Nasopharyngeal Cannula Size 6 (6 cm) Sterile – Box of 10 Units for Airway | Ref. NC6013001

82,60 €

Oropharyngeal nasopharyngeal cannula size 6 (6 cm), sterile and single-use, indicated for maintaining the airway in unconscious, sedated or anaesthetised patients. Presentation in a box of 10 units with individual packaging, ideal for anaesthesia, emergency, ICU, resuscitation and medical transport services. Intermediate size in the Cahnos range (5 to 9), recommended for older children, adolescents of small build and reduced oropharyngeal anatomies. Reference: NC6013001.

International shipping. Import duties and taxes are payable by the recipient.

Reference
NC6013001

Description

1. Introduction

The Oropharyngeal Nasopharyngeal Cannula Size 6 (Ref. NC6013001) is an essential medical device for airway management in clinical settings. Designed to separate the tongue from the posterior pharyngeal wall, it maintains respiratory patency in patients with loss of muscle tone, who are unconscious or under general anaesthesia. It is presented in a box of 10 sterile units, with individual packaging that ensures immediate use and prevents cross-contamination. Ideal for hospitals, clinics and medical centres that require reliable airway equipment, quick to place and cost-effective.

2. Technical explanation of the device

The oropharyngeal cannula (Guedel type) acts by preventing the tongue and soft tissues from collapsing against the posterior pharyngeal wall, ensuring a continuous and stable airflow during ventilation with a self-inflating bag, anaesthetic induction or cardiopulmonary resuscitation. Its anatomical curved design reproduces the morphology of the palate and pharynx, and its central channel facilitates oxygenation and suction of secretions. It is a sterile and single-use product, which prevents cross-contamination between patients. Size 6 (6 cm in length) is an intermediate size in the range, indicated for older children, adolescents of small build and reduced oropharyngeal anatomies.

3. Technical Specifications

Characteristic Specification
Reference NC6013001
Size 6 (6 cm)
Type Nasopharyngeal / Oropharyngeal (Guedel type)
Presentation Sterile, individual packaging
Units per box 10
Type of use Single-use (disposable)
Application Anaesthesia, emergency, ICU, resuscitation and patient transport
Function Maintains a patent oropharyngeal airway and prevents obstruction by the tongue
Material Medical-grade plastic (not specified on the data sheet; consult the technical department)

This reference is part of Cahnos’s range of sterile oropharyngeal cannulas, available in progressive sizes:

Reference Size Presentation
NC5011501 5 (5 cm) Box of 10 units, sterile
NC6013001 6 (6 cm) Box of 10 units, sterile
NC7015001 7 (7 cm) Box of 10 units, sterile
NC8017001 8 (8 cm) Box of 10 units, sterile
NC9019001 9 (9 cm) Box of 10 units, sterile

4. Equivalences and Cross-References

There is no official equivalence table validated by the manufacturer for reference NC6013001; it is a proprietary code of Cahnos. Before using this reference in tendering or direct substitution, consult our technical department.

At the level of functional category comparison (not interchangeable 1:1), size 6 (6 cm) corresponds to the length coding in centimetres used by most manufacturers of Guedel cannulas (sizes 0 to 12). In the Cahnos catalogue, the same size is available in the non-sterile range per unit (Ref. 830003M, Guedel ISO6) and in a high-consumption sterile presentation in a box of 50 units (Ref. 5000); they differ in presentation, rigidity and format, so they must be assessed according to protocol and consumption volume. The adjacent sizes of the same family (Refs. NC5011501 and NC7015001) complete the airway trolley stock.

5. Selection tips and variants of interest

To choose the correct size of oropharyngeal cannula, measure the distance between the labial commissure and the angle of the patient’s mandible: the length of the cannula should approximate that distance without exceeding it. As a reference, size 6 (6 cm) fits older children, adolescents of small build and reduced anatomies; smaller patients may require size 5 (Ref. NC5011501) and larger patients, sizes 7 to 9 (Refs. NC7015001, NC8017001 and NC9019001). It is recommended to lubricate the cannula before insertion and place it with a 180-degree rotation to minimise trauma. For high-consumption programmes, consider the sterile presentation in a box of 50 units (Ref. 5000) as a more economical alternative. Consult our technical-commercial team for volumes, supply conditions and configuration of airway kits adapted to your service.

Additional information

Reference

NC6013001

Product type

Oropharyngeal nasopharyngeal cannula (Guedel type)

Size

6 (6 cm)

Presentation

Box of 10 units

Sterilisation

Sterile, individual packaging

Type of use

Single-use (disposable)

Units per box

10

Application

Anaesthesia, emergency, ICU, resuscitation and patient transport

Indications

Older children, small-framed adolescents and reduced oropharyngeal anatomies

Material

Medical-grade plastic (not specified on the data sheet; consult the technical department)

Reviews

There are no reviews yet.

Be the first to review “Oropharyngeal Nasopharyngeal Cannula Size 6 (6 cm) Sterile – Box of 10 Units for Airway | Ref. NC6013001”