Description
Safe ventilation in paediatric anaesthesia and critical care
The double-lumen laryngeal mask size 1.5 Paediatric S (ref. LM1115015) is the reference supraglottic device for securing the airway of small paediatric patients (approximately 5-10 kg) quickly, atraumatically and reliably. Its translucent, anatomical body, made of PVC, polycarbonate (PC) and polyester, provides effective sealing and continuous visual monitoring of the airway during the procedure. It is supplied in a box of 5 sterile units, designed for the continuous supply of anaesthesia, paediatric intensive care, emergency departments and operating theatre services.
What a double-lumen laryngeal mask is and how it works
Unlike endotracheal intubation, the laryngeal mask is an extraglottic device that rests on the hypopharynx and seals around the laryngeal inlet with an inflatable cuff, without passing through the glottis. This makes it quicker to place, well tolerated in light anaesthetic planes and particularly useful in difficult airways.
In the double-lumen version, alongside the ventilation tube (standard 15 mm / 15M connector) runs a drainage channel through which a gastric tube can be passed or oesophageal contents evacuated, protecting the airway against regurgitation and aspiration. In this paediatric size, insertion is facilitated by a pre-inserted stylet; the pilot balloon incorporates a self-sealing valve for controlled inflation and pressure verification, and the ventilation tube is marked with the size, recommended patient weight and cuff inflation volume.
Technical specifications
| Characteristic | Value |
| Type | Inflatable supraglottic double-lumen laryngeal mask |
| Material | PVC, polycarbonate (PC) and polyester; natural latex-free |
| Configuration | Double lumen: ventilation tube + gastric drainage channel |
| Size | 1.5 Paediatric S |
| Recommended patient | 5-10 kg (standard market reference) |
| Maximum cuff inflation volume | 7 ml (standard market reference) |
| Connector | Standard 15 mm (15M) |
| Design | Anatomical and translucent, with pre-inserted stylet, pilot balloon and self-sealing valve |
| Use | Single-use |
| Sterility | Sterile, sterilised by ethylene oxide (EO) |
| Presentation | Box of 5 units |
Technical note: the detailed dimensional parameters of this size (internal diameter, external diameter and exact inflation volume) vary by manufacturer and must be confirmed with the technical data sheet before use in tender documentation. The values indicated correspond to standard market references for size 1.5 and are marked on the tube of each unit.
Paediatric double-lumen series (size guide from the Cahnos catalogue):
| Reference | Size | Recommended patient |
| LM1115015 | 1.5 Paediatric S | 5-10 kg (approx.) |
| LM1120015 | 2.0 Paediatric M | 10-20 kg (approx.) |
| LM1125015 | 2.5 Paediatric L | 20-30 kg (approx.) |
Equivalences and cross-references
There is no equivalence table validated by the manufacturer for reference LM1115015; it is recommended to consult the technical department of Cahnos before using this data sheet in tender processes or stock replacement.
Reference LM1115015 is a proprietary code of Cahnos and it has not been possible to verify it as an official manufacturer reference in open sources (non-verifiable code); it must be confirmed with the manufacturer before use in technical documentation.
Comparable at category level, not interchangeable 1:1: second-generation laryngeal masks with gastric drainage channel from other manufacturers (e.g. LMA® Supreme from Teleflex or Ambu AuraGain) respond to the same general clinical indication of supraglottic airway, but differ in design, geometry, material and manufacturer, so they should not be considered interchangeable without technical validation. Within the Cahnos catalogue, references LM1120015 (2.0) and LM1125015 (2.5) belong to the same family and differ only in size; the standard laryngeal mask series (refs. LM0030101, LM0040101 and LM0050101, in a box of 10) meets the supraglottic airway indication but without a gastric drainage channel.
Selection tips and variants of interest
The size should be chosen according to the patient’s weight and not only by age or commercial designation: for patients of 5-10 kg this size 1.5 Paediatric S is the indicated one; if the child exceeds that range, consider size 2.0 (ref. LM1120015) or 2.5 (ref. LM1125015). If the procedure does not require gastric access, the standard laryngeal mask series offers a lower cost per unit alternative. Always check the integrity of the sterile packaging and the expiry date before use; the device is single-use and must be disposed of after the procedure as healthcare waste according to current local regulations.