Description
1. Commercial Introduction
The single-use Ambu AuraGain laryngeal mask is the reference supraglottic solution for securing the airway quickly, safely and versatilely in anaesthesia, intensive care, emergency and resuscitation. This second-generation device combines in a single unit the three fundamental needs of airway management: reliable ventilation, gastric drainage and rescue intubation. Being disposable and sterile, it eliminates the risks of cross-contamination between patients and ensures a device always ready for use in every procedure.
2. Technical explanation of the device and procedure
Unlike endotracheal intubation, the laryngeal mask is an extraglottic device that rests in the hypopharynx and seals around the laryngeal inlet via an inflatable cuff, without passing through the glottis. This allows faster placement, good tolerance in light anaesthetic planes and safe use in difficult airways without the need for laryngoscopy.
- Rapid positioning: the soft, rounded curvature of the AuraGain, preformed to follow the anatomy of the human airway, ensures rapid placement and stable long-term performance. The thin, soft cuff is designed to provide high sealing pressures.
- Gastric control: the integrated gastric access channel, with a low-friction inner surface, facilitates the placement of a gastric tube and allows active and passive management of gastric contents, preventing stomach insufflation.
- Integrated intubation capability: in the event of an unexpected difficult airway or a “cannot intubate – cannot ventilate with face mask” (CI-CV) situation, the AuraGain can be used as a conduit for direct endotracheal intubation guided by a flexible endoscope.
- Total versatility: rapid placement, high sealing pressure, gastric access and intubation capability make the AuraGain the safe choice for any procedure in which a laryngeal mask is indicated.
Includes a soft bite area with useful markings and accessory information, navigation markings to guide flexible endoscopes and direct endotracheal intubation with flexible endoscope and standard ET tubes.
3. Technical Specifications
General manufacturer information
| Maximum intra-cuff pressure | 60 cm H2O |
| Airway connector | 15 mm ISO 5356-1 |
| Tube and cuff material | PVC (latex-free and phthalate-free) |
| Patient range | Complete neonatal (AuraGain only), paediatric and adult range |
| Presentation | Sterile, ready-to-use packaging; colour-coded bag with instructions for use |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc (1 unit) |
| Device type | Medical device (medical device) |
| Device class | II A |
| CND | R01020102 |
| GMDN | 45036 |
Available references
| Reference | Size | Sales unit | Details |
|---|---|---|---|
| GM57600 | 1 | 1 pc | Laryngeal mask N 1 (dead space reduced by up to 39%) · Patient weight: <5 kg · Max ET tube (Ø of endotracheal tube): 3.5 mm · Max gastric tube: 6 FR · Maximum cuff inflation volume: 4 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57601 | 1.5 | 1 pc | Laryngeal mask N 1.5 (dead space reduced by up to 39%) · Patient weight: 5-10 kg · Max ET tube (Ø of endotracheal tube): 4.0 mm · Max gastric tube: 8 FR · Maximum cuff inflation volume: 7 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57602 | 2 | 1 pc | Laryngeal mask N 2 · Patient weight: 10-20 kg · Max ET tube (Ø of endotracheal tube): 5.0 mm · Max gastric tube: 10 FR · Maximum cuff inflation volume: 10 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57603 | 2.5 | 1 pc | Laryngeal mask N 2.5 · Patient weight: 20-30 kg · Max ET tube (Ø of endotracheal tube): 5.5 mm · Max gastric tube: 10 FR · Maximum cuff inflation volume: 14 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57604 | 3 | 1 pc | Laryngeal mask N 3 · Patient weight: 30-50 kg · Max ET tube (Ø of endotracheal tube): 6.5 mm · Max gastric tube: 16 FR · Maximum cuff inflation volume: 20 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57605 | 4 | 1 pc | Laryngeal mask N 4 · Patient weight: 50-70 kg · Max ET tube (Ø of endotracheal tube): 7.5 mm · Max gastric tube: 16 FR · Maximum cuff inflation volume: 30 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57606 | 5 | 1 pc | Laryngeal mask N 5 · Patient weight: 70-100 kg · Max ET tube (Ø of endotracheal tube): 8.0 mm · Max gastric tube: 16 FR · Maximum cuff inflation volume: 40 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
| GM57607 | 6 | 1 pc | Laryngeal mask N 6 · Patient weight: >100 kg · Max ET tube (Ø of endotracheal tube): 8.0 mm · Max gastric tube: 16 FR · Maximum cuff inflation volume: 50 ml · Rapid placement · Gastric control · Integrated intubation capability · Total versatility |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer that cross-references the 57600-57607 references with specific codes from other brands for second-generation laryngeal masks with gastric drainage channel. The options indicated are comparable at category level (not interchangeable 1:1) and must be validated field by field before any substitution in tenders or protocols:
- Second-generation laryngeal masks with gastric drainage channel from other manufacturers (e.g. LMA® Supreme from Teleflex, i-gel from Intersurgical or Ambu’s own AuraGain series) respond to the same general clinical indication for supraglottic airway, but differ in design, geometry, material and manufacturer.
- Within the Cahnos/GIMA catalogue, the series of double-lumen laryngeal masks with gastric drainage tube is the closest homologous family: refs. LM1115015 (size 1.5), LM1120015 (2.0), LM1125015 (2.5), LM1130015 (3.0) and LM1140015 (4.0), in a box of 5 units.
- The standard series of laryngeal masks with epiglottis elevating bars (refs. Ref. 57580-57585; Cahnos codes LM0010101 to LM0050101, manufacturer Grupo Unidix 833310-833350, in a box of 10 units) meets the same indication for supraglottic airway, but without a gastric drainage channel or integrated intubation capability.
Always consult the technical department of Cahnos before using these references as a direct substitute in tender specifications or stock replacement.
5. Selection tips and variants of interest
The main selection criterion should be the patient’s weight, not age or commercial designation. The AuraGain range is ordered by size, from 1 to 6, covering from neonates (<5 kg) to patients over 100 kg: size 1 (<5 kg), 1.5 (5-10 kg), 2 (10-20 kg), 2.5 (20-30 kg), 3 (30-50 kg), 4 (50-70 kg), 5 (70-100 kg) and 6 (>100 kg).
For services that manage risk of regurgitation or aspiration, the integrated gastric channel of the AuraGain (GM57600-GM57607) recommends this family over standard masks without drainage. If a difficult airway scenario is also anticipated, the ability to intubate through the mask with a flexible endoscope and standard ET tubes adds an extra layer of safety. It is always recommended to verify the integrity of the sterile packaging and the expiry date before use; the device is single-use and must be disposed of after the procedure as medical waste in accordance with current local regulations. For complete provision of units, wards or supply contracts, consult the technical-commercial team of Cahnos for conditions and a formalised quote. For large orders you can request a quote.





Reviews
There are no reviews yet.