Description
1. Commercial Introduction
The oral uncuffed endotracheal tube with Murphy eye, ID 3.0 mm (Ref. ETAN30002) is the airway solution that anaesthesia, emergency and intensive care departments need to ensure positive pressure ventilation and anaesthesia administration when a ventilation face mask cannot be used. Made of medical-grade polyvinyl chloride (PVC), it offers durability, controlled flexibility and biocompatibility for critical procedures in small patients. Supplied in a box of 10 units, designed to keep hospital stock always available in high-turnover units such as NICUs, paediatric operating theatres and emergency bays.
2. Technical explanation of the device
In orotracheal intubation, the tube is inserted through the mouth, passes through the glottis and lodges in the trachea to convey gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. As it is an uncuffed tube, the seal is achieved by the anatomical fit of the tube against the tracheal wall, making it especially indicated when cuff inflation is contraindicated or unnecessary, common practice in small-calibre airways and in neonatal and paediatric patients. The Murphy eye, a lateral opening located at the distal end, acts as an alternative ventilation pathway: if the main lumen becomes obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening. The Magill-type curvature, the standard 15 mm connector, the radiopaque line and the depth markings facilitate placement and radiographic verification. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | ETAN30002 (Cahnos proprietary code) |
| Type | Oral endotracheal (orotracheal), Magill-type curvature |
| Internal diameter (ID) | 3.0 mm |
| Sleeve | Without sleeve |
| Murphy eye | Present, distal lateral safety orifice |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Connector | 15 mm standard (ISO 5356-1) |
| Marking | Radiopaque line and depth graduation |
| Use | Single-use, disposable (sterile) |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
ETAN series without cuff with Murphy eye: the family to which this reference belongs covers the following sizes documented in the catalogue, all with the same configuration and box of 10 units presentation:
| Inner diameter | Reference (box of 10 units) |
|---|---|
| 2.0 mm | ETAN20002 |
| 2.5 mm | ETAN25002 |
| 3.0 mm | ETAN30002 (this product) |
| 3.5 mm | ETAN35002 |
| 4.0 mm | ETAN40002 |
| 4.5 mm | ETAN45002 |
| 5.0 mm | ETAN50002 |
| 5.5 mm | ETAN55002 |
| 6.0 mm | ETAN60002 |
Note: verify the declaration of conformity, the CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures. Applicable reference standard: ISO 5361 (respiratory and anaesthetic equipment, tracheal tubes and connectors).
4. Equivalences and Cross-References
The SKU ETAN30002 is Cahnos’s own code (ETAN series) for this generic PVC oral tracheal tube; it should not be confused with the official reference number of any specific manufacturer. As of today, there is no manufacturer-validated equivalence table for this reference, so we classify the following options as comparable at category level (same product type and clinical indication; not interchangeable 1:1), verified against official sources:
| Manufacturer / line | Description | Reference (ID 3.0 mm) |
|---|---|---|
| P. J. Dahlhausen (official manufacturer’s catalogue) | Magill endotracheal tube without cuff, with Murphy eye, without stylet, sterile, box of 10 | 44.000.11.030 |
| Teleflex (Rüsch® Safety Clear®, official catalogue) | Uncuffed endotracheal tube, Murphy eye, 3.0 mm; length 160 mm, OD 4 mm, sterile, box of 10, latex-free | 100382030 |
| Asid Bonz / Well Lead (ENDOSID®, Cahnos catalogue) | Magill endotracheal tube without balloon with Murphy eye, ID 3 mm, box of 10 | 843030 |
These references share indication, size and general configuration, but may differ in the exact PVC compound, length, outer diameter (OD), bevel geometry and Murphy eye design; they must be checked sheet by sheet against the manufacturer before any direct substitution in tenders. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before using it as an equivalence in specifications or tenders.
5. Selection tips and variants of interest
Size selection (common use in clinical practice, not manufacturer’s specification): the ID 3.0 mm size is intended for neonates, infants and small paediatric patients, as well as adults with very small-calibre airways. As a general guide, in premature and neonatal patients sizes from 2.0 to 3.5 mm are used. The final choice must be based on the department’s protocol and anaesthetic assessment (age, weight and estimated airway calibre).
Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the standard 15 mm connector. As it lacks a cuff, special attention must be paid to the fit of the tube in the trachea to minimise leaks and risk of aspiration.
Variants of interest in the catalogue: if you need another size, the ETAN series without cuff covers from 2.0 to 6.0 mm and above (ETAN20002 onwards). For procedures requiring a leak-tight seal or prolonged ventilation, consider the cuffed version of the same size (Ref. ETAN30C02); if there is a risk of kinking or external compression, the reinforced uncuffed tube (Ref. ETA030002A2); and for nasal approach, consult the nasopharyngeal tube lines in the catalogue. Contact our technical-commercial team at Cahnos for reference approval and the configuration of the most suitable size stock for your department.





Reviews