Description
1. Introduction
The oral tracheal endotracheal tube without cuff and with Murphy eye, 10.0 mm (Ref. ETAN10002) is the airway solution that anaesthesia, emergency and intensive care services need when a face mask is not a viable option. Manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines durability, controlled flexibility and biocompatibility for critical procedures. Its cuffless design, together with a wide internal lumen of 10.0 mm, makes it especially suitable for adult patients with a large-calibre airway or situations requiring a high gas flow. It is supplied in a box of 10 units, individually packaged and sterile, designed to maintain a hospital stock always available in high-turnover units.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. As it is a cuffless tube, sealing is achieved by the anatomical fit of the calibre against the tracheal wall, so it is especially indicated when cuff inflation is contraindicated or unnecessary. The Murphy eye, a lateral opening at the distal end, acts as an alternative ventilation route: if the main lumen becomes obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening, ensuring continuity of ventilation. The Magill curve, atraumatic rounded tip, radiopaque contrast line and depth marks facilitate safe placement and radiographic verification. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
| Reference (SKU) | ETAN10002 (distributor SKU Cahnos) |
| Type | Oral endotracheal tube (orotracheal), Magill curvature |
| Internal diameter (ID) | 10.0 mm |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, flexible and durable |
| Latex | Natural latex-free |
| Sleeve | Cuffless (sealed by anatomical fit of the size) |
| Murphy eye | Present, distal lateral safety orifice |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth markings |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, disposable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
The ETAN series (oral tracheal tubes without cuff with Murphy eye), to which this reference belongs, covers the following calibres in the same configuration and presentation of a box of 10 units:
| Inner diameter | Reference (box of 10 units) |
| 2.0 mm | ETAN20002 |
| 2.5 mm | ETAN25002 |
| 3.0 mm | ETAN30002 |
| 3.5 mm | ETAN35002 |
| 4.0 mm | ETAN40002 |
| 4.5 mm | ETAN45002 |
| 5.0 mm | ETAN50002 |
| 5.5 mm | ETAN55002 |
| 6.0 mm | ETAN60002 |
| 6.5 mm | ETAN65002 |
| 7.0 mm | ETAN70002 |
| 7.5 mm | ETAN75002 |
| 8.0 mm | ETAN80002 |
| 8.5 mm | ETAN85002 |
| 9.0 mm | ETAN90002 |
| 9.5 mm | ETAN95002 |
| 10.0 mm | ETAN10002 (this product) |
Note: tracheal tubes are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the declaration of conformity and the manufacturer’s CE/MDR marking on each supplied batch. The outer diameter (OD) and total length in this calibre could not be verified against official public sources from the manufacturer; they remain pending confirmation with the technical department before use in tenders or stock replacement.
4. Equivalences and Cross-References
The SKU ETAN10002 is Cahnos’ own code (ETAN series) for this oral tracheal tube in PVC; the ETAN family follows the nomenclature of the DEAFLUX line of Magill tracheal tubes, but it must not be confused with the official part number of any other specific manufacturer. There is currently no equivalence table validated by the manufacturer for this reference, so we classify the following options according to their degree of correspondence:
- Comparable at category level (not 1:1 interchangeable): in documented calibres from the Cahnos catalogue, the same configuration (Magill without cuff with Murphy eye) is found in the ENDOSID series (e.g. Ref. 843040 in 4.0 mm or Ref. 843060 in 6.0 mm); for the 10.0 mm calibre, the exact code for this series is pending confirmation with the manufacturer or distributor.
- Market comparables, pending technical verification: Magill tracheal tubes without cuff with Murphy eye from the 44.000.11.xxx series by P. J. Dahlhausen and from the Safety Clear® line by Teleflex/Rüsch; the specific codes for 10.0 mm must be confirmed against each manufacturer’s official datasheet before use, as they may differ in PVC compound, length, distal profile and marking system.
- Complementary references of the same 10.0 mm calibre in the Cahnos catalogue: ETAN10C02 (with cuff and Murphy eye, same calibre) and reinforced version without cuff from the ETAN series (code to be confirmed following the documented nomenclature ETA0xxxx02A2, e.g. ETA0100002A2).
There is no equivalence table validated by the manufacturer for this generic distributor reference; consult the Cahnos technical department before using this reference as an equivalence in specifications or tenders or as a direct replacement for another brand.
5. Selection tips and variants of interest
- Calibre selection (usual use in clinical practice, not manufacturer specification): the 10.0 mm ID calibre is intended for large adult patients or those with a wide-calibre airway requiring a large cross-section lumen for high gas flow; the final choice must be based on each patient’s age, weight and individual anaesthetic assessment. As it lacks a cuff, special attention must be paid to the fit of the tube in the trachea to minimise leaks and the risk of aspiration in protocols where sealing is critical.
- Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the 15 mm connector to the circuit, as well as the expiry date of sterility.
- Variants of interest in the Cahnos catalogue: if you need an airtight seal or prolonged ventilation, consider the cuffed tube of the same size (Ref. ETAN10C02); if there is a risk of kinking or external compression, consider the reinforced version of the ETAN series; and if you need another size, the ETAN series covers from 2.0 mm to 10.0 mm (ETAN20002 to ETAN10002) in the same configuration. Complement with water-soluble lubricant, introducer or intubation stylet and anaesthetic face mask with valve, available from Cahnos to fully equip the anaesthesia and intensive care unit.
Contact the technical-commercial department at Cahnos for samples, volume conditions and approval of references for your tender.




Reviews