Description
1. Introduction
The oral endotracheal tube without cuff and with Murphy eye of 6.5 mm (Ref. ETAN65002) is the airway solution that anaesthesia, emergency and intensive care services need to ensure patient ventilation when the use of a face mask is not viable. Made of polyvinyl chloride (PVC), it offers durability, controlled flexibility and compatibility with the medical safety standards required in critical procedures. It is presented in a box of 10 units, designed to maintain a hospital stock always available.
2. What it is and how it works
In orotracheal intubation, the tube is inserted through the mouth, passes through the glottis and is placed in the trachea to conduct gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. As it is a without cuff tube, sealing is achieved by the anatomical fit of the tube against the tracheal wall, so it is especially indicated when cuff inflation is contraindicated or not necessary (common practice in paediatric patients and in reduced-calibre airways). The Murphy eye, a lateral opening located in the distal area, acts as an alternative ventilation route: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference | ETAN65002 |
| Type | Endotracheal oral (orotracheal) |
| Sleeve | Without sleeve |
| Murphy eye | Present |
| Internal diameter (ID) | 6.5 mm |
| Material | Medical-grade polyvinyl chloride (PVC) |
| Presentation | Box of 10 units |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
ETAN series (oral tracheal tubes without cuff with Murphy eye): the family to which this reference belongs covers the following calibres documented in the catalogue, all with the same configuration and presentation in a box of 10 units:
| Inner diameter | Reference (box of 10 units) |
|---|---|
| 2.5 mm | ETAN25002 |
| 3.5 mm | ETAN35002 |
| 4.5 mm | ETAN45002 |
| 5.5 mm | ETAN55002 |
| 6.0 mm | ETAN60002 |
| 6.5 mm | ETAN65002 (this product) |
| 7.5 mm | ETAN75002 |
| 8.5 mm | ETAN85002 |
Note: verify the declaration of conformity and the manufacturer’s CE/MDR marking on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The SKU ETAN65002 is Cahnos’ own code (ETAN series) for this generic oral tracheal tube in PVC; it should not be confused with the official reference number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference, so we classify the following options as comparable at category level (not 1:1 interchangeable), pending technical verification against each manufacturer’s official datasheet:
- ETA065002A2 – reinforced oral endotracheal tube without cuff with Murphy eye, DI 6.5 mm (Cahnos catalogue): same calibre and configuration, but with a metal spiral reinforcement that provides greater resistance to kinking; differs in construction and price.
- ETAN65C02 – oral endotracheal tube with cuff and Murphy eye, DI 6.5 mm (Cahnos catalogue): same calibre and base design, but incorporates a cuff for an airtight seal; it is not interchangeable with the cuffless version.
- Other calibres in the ETAN series: they share design and presentation; only the internal diameter varies (see table in block 3).
There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids.
5. Selection tips and variants of interest
Calibre selection (usual use in clinical practice, not manufacturer specification): the cuffless tube is frequently used in paediatric patients and in those in whom cuff inflation is contraindicated. The 6.5 mm calibre is aimed at adolescents and adults of small build or with a reduced-calibre airway. The final choice should be based on the service protocol and the patient’s anaesthetic assessment.
Verification before intubation: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the connector. As it lacks a cuff, special attention must be paid to the fit of the tube in the trachea to minimise leaks and the risk of aspiration.
Variants of interest in the catalogue: if you need another calibre, the ETAN series covers from 2.5 mm to 8.5 mm (ETAN25002 to ETAN85002). For procedures requiring an airtight seal, consider the cuffed tube (Ref. ETAN65C02); in case of risk of kinking or external compression, the spiral-reinforced one (Ref. ETA065002A2); and for head and neck surgery or special positions, consult the preformed lines and intubation kits in the catalogue. Consult our technical-commercial team at Cahnos for the approval of references and the configuration of the most suitable size stock for your service.





Reviews