Description
1. Introduction
The reinforced oral endotracheal tube with cuff, guide and Murphy eye, 3.0 mm (ref. ETAM30C02A1) is the airway solution that anaesthesia, emergency and intensive care services need when face mask ventilation is not viable in neonatal patients. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the anti-kink helical reinforcement with the airtight seal of the cuff and the safety of the Murphy eye, offering a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, ready for restocking the intubation trolley, the neonatal ICU and the operating theatre with a uniform and reliable standard.
2. Technical explanation of the device and procedure
Orotracheal intubation involves inserting the tube orally under laryngoscopic vision, aided by the included insertion guide (stylet/introducer) which provides controlled rigidity during advancement and is removed once the tube is placed. The helical reinforcement embedded in the PVC wall prevents kinking and collapse of the tube in response to flexion, head and neck movements, biting or external compression, maintaining airway patency in complex positions. The cuff, inflated via the pilot balloon with a self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive pressure ventilation. The Murphy eye, a distal lateral opening, acts as an alternative ventilation pathway: if the tip of the tube becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through this opening and occlusion is never complete. The radiopaque line and depth graduation allow radiographic verification of correct position. It is a single-use device: it must be discarded after each patient to avoid cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference (SKU) | ETAM30C02A1 (own code of distributor Cahnos) |
| Type | Oral endotracheal tube (orotracheal), reinforced, with cuff, guide and Murphy eye |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 3.0 mm (approximate indicative size of 12 Fr according to common market use) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Reinforcement | Integrated helical spiral, kink resistance |
| Sleeve | Cuff inflation with pilot balloon and self-sealing valve |
| Insertion guide | Included (insertion guide/stylet, removed after placement) |
| Murphy eye | Present (distal lateral safety opening) |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth scale |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, non-reusable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; the connector complies with the corresponding part of standard ISO 5356-1. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification in each supplied batch before use in procedures.
Range of sizes available at Cahnos (ETAM family, reinforced with cuff, guide and Murphy eye):
| Reference | Internal diameter (ID) | Indicative patient |
|---|---|---|
| ETAM30C02A1 | 3.0 mm | This product – Neonate |
| ETAM35C02A1 | 3.5 mm | Newborn |
| ETAM40C02A1 | 4.0 mm | Child |
| ETAM45C02A1 | 4.5 mm | Child |
| ETAM50C02A1 | 5.0 mm | Child |
| ETAM55C02A1 | 5.5 mm | Older child / small adult |
| ETAM60C02A1 | 6.0 mm | Small adult |
| ETAM65C02A1 | 6.5 mm | Small adult |
| ETAM70C02A1 | 7.0 mm | Adult |
| ETAM75C02A1 | 7.5 mm | Adult |
| ETAM80C02A1 | 8.0 mm | Adult |
| ETAM85C02A1 | 8.5 mm | Adult / large adult |
| ETAM90C02A1 | 9.0 mm | Large adult |
| ETAM95C02A1 | 9.5 mm | Large adult |
4. Equivalences and Cross-References
The SKU ETAM30C02A1 is an own code of Cahnos (ETAM series: reinforced oral tracheal tubes with cuff and guide) and does not correspond to the official part number of any specific manufacturer published in public sources. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tender specifications, bids or direct replacement of stock from another brand.
The following options are classified as comparable at category level (not interchangeable 1:1, pending technical verification against the official datasheet of each manufacturer; they differ in outer diameter, total length, distal tip geometry and cuff characteristics):
| Reference / Line | Description | Degree of correspondence |
|---|---|---|
| ETA030C02A2 (Cahnos) | Reinforced oral tube with cuff and Murphy eye, ID 3.0 mm, without guide | Comparable by category; differs in the included guide |
| ETAN30C02 (Cahnos) | Oral tube with cuff and Murphy eye, ID 3.0 mm, without reinforcement | Comparable by category; without helical reinforcement |
| ETPN30C02 (Cahnos) | Preformed nasal tracheal tube with cuff, ID 3.0 mm (indicative) | Comparable by category; nasal route, pending confirmation |
| ETSL30C02 (Cahnos) | Oral tube with cuff and subglottic suction lumen, ID 3.0 mm (indicative) | Comparable by category; suction lumen, pending confirmation |
| Rüsch® / Sheridan® (Teleflex) | Line of reinforced tubes with cuff (spiral reinforcement) | Comparable by category; not interchangeable 1:1 without datasheet verification |
| Shiley™ / Mallinckrodt™ (Medtronic), Portex® Blue Line® (ICU Medical) | Market lines of reinforced oral tubes with cuff | Comparable by category; not interchangeable 1:1 without datasheet verification |
Fields to compare before comparing: internal diameter (3.0 mm), material (PVC), cuff type, presence of guide, Murphy eye, 15 mm connector and helical reinforcement. Any difference in one of these fields places the comparison at category level, not exact equivalence.
5. Selection tips and variants of interest
Size selection (common use in clinical practice, not manufacturer specification): the 3.0 mm ID is intended for neonatal and premature patients; as a general guide, in neonatology sizes from 2.5 to 3.5 mm are used depending on gestational age and weight. The final choice should be based on the service protocol and anaesthetic assessment, always selecting the largest size compatible with the patient’s anatomy and airway.
Cuff pressure: check the integrity of the cuff, pilot balloon and lumen patency before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range, indicative), monitoring with a manometer if the service has one, to minimise pressure injury to the tracheal mucosa.
Prior verification: check the correct fixation and removal of the guide after placement, the patency of the Murphy eye and the anchoring of the 15 mm connector to the circuit.
Variants of interest: if no guide is required, consider ref. ETA030C02A2 (reinforced with cuff, same size); for an airtight seal without reinforcement, ref. ETAN30C02; and if you need larger sizes from the same family, refs. ETAM35C02A1 / ETAM40C02A1. For prolonged intubations with risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL series). Complement with water-soluble lubricant and an introducer or stylet, available at Cahnos, to fully equip the neonatal intubation trolley. For volume conditions, samples or hospital supply lead times, contact the technical-commercial department of Cahnos for the approval of references and the configuration of the most suitable size stock for your service.