Description
1. Introduction
The oral reinforced endotracheal tube with cuff, guide and Murphy eye (ref. ETAM70C02A1) is a single-use device designed to maintain a patent and stable airway in critical situations: positive-pressure ventilation, administration of general anaesthesia and management of the patient in intensive care when mask ventilation is not possible. Its helical reinforcement makes it the reference option when tube movement, special positioning or head and neck surgery are anticipated. It is supplied in a box of 10 units, ready for restocking intubation trolleys, ICU bays and operating theatres.
2. Technical explanation of the device and procedure
Orotracheal intubation involves introducing the tube orally, through the glottis, until its distal end is positioned in the trachea, below the vocal cords. The included guide facilitates insertion and correct positioning, providing controlled rigidity during advancement and allowing its removal once the tube is placed.
The reinforced body (spiral incorporated into the PVC wall) prevents tube collapse under external compression, biting or kinking, maintaining airway patency in complex positions. The cuff, inflated via the pilot balloon, seals the tracheal lumen and allows positive-pressure ventilation without leaks, as well as preventing aspiration of secretions. The Murphy eye, a lateral opening near the distal tip, acts as a safety route: if the tip rests against the tracheal or bronchial wall, respiratory flow continues through this opening, preventing total occlusion.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | ETAM70C02A1 |
| Type | Reinforced oral endotracheal tube with cuff |
| Internal diameter (ID) | 7.0 mm |
| Access route | Oral (orotracheal) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent |
| Reinforcement | Integrated helical spiral, kink resistance |
| Insertion guide | Yes, included |
| Sleeve | Cuffed, inflated via pilot balloon with Luer connection |
| Murphy eye | Present (distal lateral safety opening) |
| Connector | Universal 15 mm (ISO 5356-1) |
| Radiopacity | X-ray contrast line |
| Latex | Natural rubber latex-free |
| Sterility | Sterile, individually packaged (ethylene oxide) |
| Use | Single-use, non-reusable |
| Indications | Positive pressure ventilation and anaesthesia administration |
| Presentation | Box of 10 units |
Range of sizes available from Cahnos (ETAM family, reinforced with cuff and guide):
| Reference | Internal diameter (ID) | Indicative patient |
|---|---|---|
| ETAM30C02A1 | 3.0 mm | Newborn |
| ETAM35C02A1 | 3.5 mm | Newborn |
| ETAM45C02A1 | 4.5 mm | Child |
| ETAM50C02A1 | 5.0 mm | Child |
| ETAM55C02A1 | 5.5 mm | Child / small adult |
| ETAM65C02A1 | 6.5 mm | Small adult |
| ETAM70C02A1 (this product) | 7.0 mm | Adult |
| ETAM75C02A1 | 7.5 mm | Adult |
| ETAM80C02A1 | 8.0 mm | Adult |
| ETAM85C02A1 | 8.5 mm | Adult / large adult |
| ETAM90C02A1 | 9.0 mm | Large adult |
| ETAM95C02A1 | 9.5 mm | Large adult |
4. Equivalences and Cross-References
Functional category equivalence (not interchangeable 1:1). By clinical indication (oral reinforced endotracheal tube with cuff and Murphy eye, ID 7.0 mm) this product is comparable to reinforced tubes from manufacturers such as Teleflex (Rüsch®), Medtronic (Shiley™ / Mallinckrodt™) and ICU Medical (Portex® Blue Line®). All these brands offer oral tubes with helical reinforcement to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and cuff characteristics, so they must be compared specification by specification before replacing a specific product.
The reference ETAM70C02A1 is a proprietary code of the Cahnos range; it does not correspond to an official manufacturer part number published in public sources, so it must be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code. There is no equivalence table validated by the manufacturer for this reference; consult the Cahnos technical department before using it in tenders or as a stock replacement.
Comparable by category within the Cahnos catalogue (same ID 7.0 mm, other configurations):
| Reference | Description |
|---|---|
| ETA070C02A2 | Oral reinforced endotracheal tube with cuff, without guide |
| ETAN70C02 | Oral endotracheal tube with cuff and Murphy eye, without reinforcement |
| ETPN70C02 | Preformed nasal tracheal tube with cuff and Murphy eye |
| ETSL70C02 | Oral endotracheal tube with cuff and subglottic suction lumen |
These references are comparable at category level, not interchangeable 1:1: each configuration addresses a specific indication (reinforcement, guide, subglottic suction, nasal route, etc.).
5. Selection tips and variants of interest
ID 7.0 mm is commonly used in adult patients; the general intubation range in adults is 7.0 to 9.0 mm depending on build, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
Verify the integrity of the cuff and pilot balloon before insertion and control the sealing pressure with a manometer, keeping it within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm the service protocol).
The reinforced tube with guide is especially indicated when frequent repositioning, prone positioning, head and neck surgery or risk of kinking are anticipated. If intubation is to be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the range with subglottic suction lumen (ETSL70C02). For procedures where a guide is not required, the standard reinforced ETA070C02A2 can be selected; for nasal approaches, the preformed ETPN70C02. For volume conditions, samples or hospital supply lead times, contact the Cahnos technical and commercial department.





Reviews