Description
1. Commercial Introduction
The Reinforced Orotracheal Endotracheal Tube without Cuff with Murphy Eye of 8.0 mm (Ref. ETA080002A2) is the solution that your anaesthesia, intensive care, emergency or resuscitation department needs to ensure a patent and reliable airway in critical procedures. Its medical-grade PVC construction and reinforced wire offer the necessary resistance to keep the lumen open even under external pressure, patient movement or frequent repositioning. A professional choice, available in a box of 10 units and with immediate delivery from Cahnos.
2. Technical explanation of the device
The tube is inserted orally through the glottis into the trachea and is connected at its proximal end to the ventilator, anaesthesia circuit or resuscitation bag via the universal 15 mm connector (conforming to ISO 5356-1). As it lacks a cuff, sealing is achieved by the fit of the calibre against the tracheal wall, making it suitable for procedures of limited duration or protocols where the inflatable cuff and the risk of pressure injury to the mucosa are avoided.
The Murphy eye, a lateral orifice located at the distal tip, acts as a backup ventilation pathway: if the main lumen were obstructed by secretions or kinking, airflow continues through this opening. The reinforced spiral integrated into the tube wall prevents kinking and collapse, maintaining airway patency throughout ventilation. The transparent material allows patency to be checked by condensation, and the radiopaque line with depth graduation facilitates radiographic position control.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | ETA080002A2 |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 8.0 mm |
| Configuration | Reinforced, cuffless (sealed by size fit) |
| Murphy eye | Present, distal lateral safety orifice |
| Reinforcement | Helical anti-kink spiral integrated into the wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Connector | Universal 15 mm (ISO 5356-1) |
| Marking | Radiopaque line and depth graduation |
| Sleeve | Without cuff (facilitates insertion and reduces complications) |
| Indication | Positive-pressure ventilation and administration of anaesthesia when the use of a face mask is not possible. |
| Use | Single-use, non-reusable |
| Sterilisation | Ethylene oxide (EO), sterile supply |
| Presentation | Box of 10 units |
| Indicative population | Adult (usual adult range: ID 7.0–8.5 mm) |
This calibre belongs to the range of reinforced oral uncuffed endotracheal tubes from Cahnos (ETA series), available in several diameters to complete the department’s stock:
| Reference | ID (mm) |
|---|---|
| ETA030002A2 | 3.0 |
| ETA040002A2 | 4.0 |
| ETA050002A2 | 5.0 |
| ETA060002A2 | 6.0 |
| ETA070002A2 | 7.0 |
| ETA075002A2 | 7.5 |
| ETA080002A2 (this product) | 8.0 |
| ETA085002A2 | 8.5 |
| ETA090002A2 | 9.0 |
| ETA095002A2 | 9.5 |
| ETA010002A2 | 10.0 |
4. Equivalences and Cross-References
The reference ETA080002A2 is a proprietary code from the Cahnos catalogue. For this specific configuration (oral, reinforced, uncuffed, with Murphy eye, ID 8.0 mm) there is no manufacturer-validated equivalence table in the official sources consulted; therefore, the following references are offered as a functional category comparison, not interchangeable 1:1, and must be confirmed with the technical department before use in tendering:
| Manufacturer | Reference | Description | Key difference |
|---|---|---|---|
| Endosid® (Asid Bonz) | 849080 | Spiral-reinforced endotracheal tube with Murphy eye, ID 8.0 mm | With cuff; same family and calibre, different configuration (with balloon) |
| Dahlhausen | 44.000.20.080 | Reinforced endotracheal tube, ID 8.0 mm | With cuff; same material and same family, different configuration |
| Dahlhausen | 44.000.11.080 | Magill endotracheal tube without cuff, ID 8.0 mm | Without spiral reinforcement; comparable by category, not interchangeable |
At market level, 8.0 mm uncuffed endotracheal tubes fall into the same functional category as lines such as Teleflex (Rüsch®), Medtronic (Shiley™), ICU Medical (Portex®) or Intersurgical: same general clinical indication, but it is essential to verify in each technical data sheet the diameter, material, presence of Murphy eye and type of reinforcement before replacing the device in a care protocol. There is no manufacturer-validated equivalence table; consult the technical department of Cahnos before use in tendering.
5. Selection tips and variants of interest
The 8.0 mm ID is reserved for adult patients of medium to large build; as a general guide, in adults tubes of 7.0 to 8.5 mm are used depending on build and airway, always selecting the largest size compatible with the patient’s anatomy. As it is an uncuffed tube, the choice of size determines the seal: an appropriate calibre minimises leaks and avoids mucosal damage.
The uncuffed configuration is the appropriate option for procedures of limited duration, patients with a contraindication to a cuff, and protocols where a less traumatic insertion is preferred. If the procedure requires an airtight seal or long-duration ventilation, consider the cuffed variant of the same size (Ref. ETA080C02A2); if anti-kink reinforcement is not required, the standard uncuffed variant of the same calibre (Ref. ETAN80002). Complete the intubation trolley stock with the adjacent calibres in the range (ETA075002A2, ETA085002A2) and consult your technical-commercial delegate at Cahnos for volume conditions and hospital supply lead times. Single-use device: dispose of it after removal and follow the centre’s healthcare waste management protocols.