Description
1. Introduction
The Reinforced Oral Endotracheal Tube with Cuff, Stylet and Murphy Eye, ID 4.5 mm (Ref. ETAM45C02A1) is the airway solution that anaesthesia, emergency and intensive care services need when mask ventilation is not possible. Made of medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of helical reinforcement with the leak-proof seal of the cuff and the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 units, individually packaged, ideal for the intubation trolley and high-turnover hospital consumables.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is introduced through the mouth under laryngoscopic vision with the aid of the included intubation stylet, passes through the glottis and is placed in the trachea, conducting gases from the ventilator, anaesthetic circuit or resuscitation bag to the lungs. The helical spiral reinforcement embedded in the tube wall prevents kinking and collapse during flexion, head and neck movements or external compression, making it especially suitable for ENT, maxillofacial, thyroid surgery or complex surgical positions. The cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of gastric or pharyngeal contents and stabilises the device during positive-pressure ventilation. The Murphy eye, a distal lateral opening, acts as an alternative ventilation route: if the tube tip becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through this opening and occlusion is never complete. The radiopaque line and depth graduation allow radiographic verification of the correct tube position. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference (SKU) | ETAM45C02A1 (Cahnos distributor’s own code) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 4.5 mm |
| Reinforcement | Helical spiral anti-kink reinforcement in the tube wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Yes, cuff inflation with pilot balloon and self-sealing valve |
| Intubation guide | Included (insertion stylet/guide) |
| Murphy eye | Present, distal lateral safety orifice |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, disposable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Confirmed variants of the same size in the Cahnos catalogue:
| Reference | Description | Key difference |
|---|---|---|
| ETAM45C02A1 | This product: oral reinforced with cuff, stylet and Murphy eye, ID 4.5 mm | Includes intubation stylet |
| ETA045C02A2 | Oral reinforced with cuff and Murphy eye, ID 4.5 mm | Without intubation stylet |
| ETAN45C02 | Oral with cuff and Murphy eye, ID 4.5 mm | Without helical reinforcement |
| ETA045002A2 | Oral reinforced without cuff, with Murphy eye, ID 4.5 mm | Without cuff |
| ETAN45002 | Oral without cuff, with Murphy eye, ID 4.5 mm | Without cuff or reinforcement |
| ETAM40C02A1 | Oral reinforced with cuff, stylet and Murphy eye, ID 4.0 mm | Lower calibre of the ETAM series |
Applicable reference standard: ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors); universal connector conforming to ISO 5356-1. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The SKU ETAM45C02A1 is Cahnos’ own code (ETAM series: oral reinforced tracheal tubes with cuff and stylet). This family follows the technical nomenclature of the DEAFLUX line from DEAS S.r.l. (Italy), but should not be confused with the official reference number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference, so we classify the following options as comparable at category level (not 1:1 interchangeable), pending technical verification against each manufacturer’s official datasheet:
| Reference | Description | Degree of correspondence |
|---|---|---|
| ETAN45C02 (Cahnos) | Oral tube with cuff and Murphy eye, ID 4.5 mm, same indication and calibre | Comparable by category; differs in reinforcement and stylet |
| 841045 (Endosid, Cahnos) | Tube with low-pressure cuff and Murphy eye, ID 4.5 mm | Comparable by category; verify inflation system and outer diameter |
| PB-212045U (ISSO, PRO-BREATHE) | Tracheal tube with cuff, ID 4.5 mm | Comparable by category; pending verification of official data sheet |
| 44.000.10.045 / 44.000.11.045 (P. J. Dahlhausen) | Magill tracheal tubes with cuff, ID 4.5 mm | Comparable by category; exact code confirmation pending |
| Rüsch® / Sheridan (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical | Market lines of reinforced cuffed tubes | Comparable by category; not interchangeable 1:1 without datasheet verification |
There is no manufacturer-validated equivalence table for this reference; consult the Cahnos technical department before using this reference as an equivalence in tenders or bids or as a direct substitute for another brand.
5. Selection tips and variants of interest
Calibre selection (usual practice in clinical use, not manufacturer specification): the 4.5 mm ID is intended for paediatric patients, small airways or reduced calibre; the final choice should be based on each patient’s age, weight and anaesthetic assessment, and on the service protocol.
Cuff pressure: check the integrity of the cuff, pilot balloon and lumen patency before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the service has one.
Prior verification: check the correct fixation and removal of the stylet after placement, the patency of the Murphy eye and the anchoring of the 15 mm connector to the circuit.
Variants of interest: if a stylet is not required, consider Ref. ETA045C02A2 (reinforced with cuff, same calibre); for a leak-proof seal without reinforcement, Ref. ETAN45C02; for smaller paediatric sizes, the ETAM series starts at ID 4.0 mm (ETAM40C02A1); and for adults, consult the 6.0–8.5 mm sizes of the same family. Contact the Cahnos technical-commercial department for samples, volume conditions and reference approval for your tender.




Reviews
There are no reviews yet.