Description
Preformed Oral Endotracheal Tube ID 9.0 mm – Airway solution for anaesthesia and critical care
The preformed oral endotracheal tube with cuff and Murphy eye (SKU ETPO90C02, ID 9.0 mm) is the perfect ally for anaesthesia, emergency and intensive care departments that need to secure the airway in large adult patients. Its preformed design, inspired by RAE-type geometry, keeps the ventilation circuit away from the surgical field, which is especially useful in oral, maxillofacial, ophthalmological and otorhinolaryngological surgery. Supplied in a box of 10 sterile units, it ensures hospital stock is always available.
What a preformed oral endotracheal tube is and how it works
In orotracheal intubation, the tube is inserted through the mouth, passes through the glottis and is placed in the trachea to conduct gases from the ventilator or anaesthesia system to the lungs. The preformed curve follows the anatomy of the upper airway: it reduces the risk of kinking, minimises local trauma and facilitates fixation of the tube in the chin area. The high-volume, low-pressure cuff seals the trachea after inflation via the pilot balloon with self-sealing valve, allowing positive pressure ventilation without significant leaks. The Murphy eye, a distal lateral opening, ensures an alternative gas passage if the tube tip becomes obstructed (for example, by secretions or by the bevel resting against the tracheal wall). A continuous radiopaque line and depth graduation allow correct placement to be verified radiographically. It is a single-use device: it must be discarded after each patient, avoiding any risk of cross-infection.
Technical specifications
| Parameter | Specification |
|---|---|
| Material | Medical-grade polyvinyl chloride (PVC), transparent and thermostable, latex-free |
| Configuration | Oral preformed with inflatable cuff and Murphy eye |
| Internal diameter (ID) | 9.0 mm (equivalent to 36 Fr) |
| Cuff type | High volume / low pressure, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, distal lateral eye |
| Connector | Standard 15 mm connector compatible with ISO circuits |
| Marking | Continuous radiopaque line and depth scale (cm) |
| Use | Single-use (sterile) |
| Presentation | Box of 10 units |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
Other sizes from the same family (same design and ETPO series SKU)
| Inner diameter | SKU (box of 10 units) |
|---|---|
| 3.5 mm | ETPO35C02 |
| 4.0 mm | ETPO40C02 |
| 4.5 mm | ETPO45C02 |
| 5.0 mm | ETPO50C02 |
| 5.5 mm | ETPO55C02 |
| 6.5 mm | ETPO65C02 |
| 7.0 mm | ETPO70C02 |
| 8.0 mm | ETPO80C02 |
| 8.5 mm | ETPO85C02 |
| 9.0 mm | ETPO90C02 |
Note: endotracheal tubes in this category are manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the declaration of conformity and the manufacturer’s CE marking on each supplied batch.
Equivalences and cross-references
SKU ETPO90C02 is Cahnos’s own code for this generic PVC reference; it should not be confused with the official part number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference; therefore we classify the following options as comparable at category level (not 1:1 interchangeable), pending technical verification against the manufacturer’s datasheet:
- RAE / AGT oral type with cuff: preformed oral tubes with cuff and Murphy eye from lines such as Rüsch AGT/RAE or AirLife Preformed Cuffed Oral (USA) respond to the same clinical indication and general geometry; the Teleflex reference 111780090 (oral RAE with cuff, 9.0 mm, box of 10) appears in authorised distributor catalogues as indicative, but is not confirmed against a primary manufacturer source and must be cross-checked before use in tenders.
- Generic imported preformed tubes (BOENMED, Greetmed, Pinmed, etc.): same category and materials (PVC with low-pressure cuff, Murphy eye, 15 mm connector, radiopaque line), with slight differences in geometry, length or cuff inflation pressure.
- Confirmed in Cahnos’s own catalogue: the diameters 8.5, 8.0, 7.0 and the rest of the ETPO series (see table) share design and presentation; only the internal diameter changes.
Consult the technical department before using this reference as an equivalence in specifications or tenders.
Selection tips and variants of interest
- Patient selection (usual clinical practice, not manufacturer specification): for a large or very large adult, ID 8.5–9.0 mm is commonly used in men and 7.5–8.5 mm in women; the final choice should be based on the department’s protocol and anaesthetic assessment.
- Cuff pressure: inflate the cuff with a syringe through the valve and maintain a sealing pressure of 20–30 cmH2O (usual clinical practice range) to avoid tracheal damage; monitor with a manometer if available in the department.
- Preferred indications: oral and maxillofacial surgery, ENT, ophthalmology and head and neck procedures where it is desirable to keep the circuit out of the operative field.
- Catalogue variants of interest: if you need other sizes, see the ETPO35C02 to ETPO85C02 series; for patients with a difficult airway or risk of kinking, consider the metal spiral-reinforced tubes in the same intubation section.





Reviews