Description
Preformed Oral Endotracheal Tube ID 5.5 mm: safety and precision in the airway
The Preformed Oral Endotracheal Tube with cuff and Murphy eye – ID 5.5 mm (SKU: ETPO55C02) is a single-use airway device designed to ensure safe, rapid and reproducible orotracheal intubation. Its preformed geometry, of the RAE/AGT type, keeps the ventilation circuit out of the operative field (particularly useful in oral, maxillofacial, otorhinolaryngological and ophthalmic surgery) and reduces the risk of tube kinking. It is supplied in a box of 10 sterile units, ideal for maintaining a continuous stock in the operating theatre, emergency departments and intensive care units.
What a preformed oral endotracheal tube is and how it works
In orotracheal intubation, the tube is introduced through the mouth, passes through the glottis and sits in the trachea to conduct gases from the ventilator or anaesthesia system to the lungs. The preformed curve follows the anatomy of the upper airway: it facilitates fixation of the tube at the chin area, minimises local trauma and prevents the circuit from interfering with the surgical field. The high-volume, low-pressure cuff seals the trachea after inflation via the pilot balloon with self-sealing valve, allowing positive-pressure ventilation without significant leaks. The Murphy eye, a distal lateral opening, ensures an alternative gas passage if the tube tip becomes obstructed (by secretions or by the bevel resting against the tracheal wall). The continuous radiopaque line and depth scale allow radiographic confirmation of correct placement. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
Technical specifications
| Parameter | Specification |
| Type | Preformed oral endotracheal tube with cuff and Murphy eye |
| Internal diameter (ID) | 5.5 mm |
| Material | Medical-grade polyvinyl chloride (PVC), transparent and thermostable, latex-free |
| Cuff | High volume / low pressure, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, a distal lateral opening that allows secondary ventilation in the event of partial obstruction of the main lumen |
| Connector | 15 mm standard, compatible with ISO circuits |
| Marking | Continuous radiopaque line and depth scale in cm |
| Use | Single-use (sterile) |
| Clinical indication | Positive pressure ventilation and administration of general anaesthesia when a ventilation face mask is not feasible |
| Presentation | Box of 10 units (SKU ETPO55C02) |
Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.
Other sizes in the same family (ETPO series, same design and presentation)
| Inner diameter | SKU (box of 10 units) |
| 3.5 mm | ETPO35C02 |
| 4.0 mm | ETPO40C02 |
| 4.5 mm | ETPO45C02 |
| 5.0 mm | ETPO50C02 |
| 5.5 mm | ETPO55C02 |
| 6.5 mm | ETPO65C02 |
| 7.0 mm | ETPO70C02 |
| 8.0 mm | ETPO80C02 |
| 8.5 mm | ETPO85C02 |
| 9.0 mm | ETPO90C02 |
Equivalences and cross-references
The SKU ETPO55C02 is Cahnos’s own code for this generic PVC reference; it must not be confused with the official part number of any specific manufacturer, and therefore no exact reference equivalence or manufacturer-validated equivalence table can be declared.
- Comparable at category level (not 1:1 interchangeable): preformed oral tubes with cuff and Murphy eye from lines such as Rüsch AGT/RAE (Teleflex) or AirLife Preformed Cuffed Oral respond to the same indication and general geometry. Any specific manufacturer reference (material, length and cuff design may differ) must be checked against the official technical data sheet before use in tendering; for the 5.5 mm size, confirmation with the manufacturer is pending.
- Comparable by category, without 1:1 verification: generic imported preformed oral tubes (BOENMED, Greetmed, Pinmed, etc.), with PVC low-pressure cuff, Murphy eye, 15 mm connector and radiopaque line, but with slight differences in geometry, length or cuff inflation pressure.
- Confirmed in Cahnos’s own catalogue: the other diameters in the ETPO series (see table) share the same design and presentation; only the internal diameter changes.
There is no manufacturer-validated equivalence table for this reference; consult Cahnos’s technical department before using this reference as an equivalence in tender documents or tenders.
Selection tips and variants of interest
- Patient selection (usual practice in clinical practice, not manufacturer specification): the ID 5.5 mm size with cuff is commonly used in older paediatric patients, adolescents or adults with a narrow airway; the final choice must always be based on the department’s protocol and anaesthetic assessment (age, weight and estimated airway size).
- Cuff pressure: inflate the cuff through the valve with a syringe and maintain a sealing pressure of 20–30 cmH2O (usual range in clinical practice) to minimise tracheal damage; monitor with a manometer if the department has one.
- Preferred indications: oral and maxillofacial surgery, ENT, ophthalmology and head and neck procedures where it is important to keep the circuit out of the operative field, as well as mechanical ventilation in intensive care.
- Catalogue variants of interest: if you need another size, the ETPO series covers from 3.5 mm to 9.0 mm (ETPO35C02 to ETPO90C02). For rapid intubation in emergency or prehospital care, consider the emergency kits with stylet and syringe (Endosid 845 series); for difficult airway or risk of kinking, the tubes reinforced with metal spiral from the same intubation section.




Reviews
There are no reviews yet.