Description
1. Introduction
The orotracheal endotracheal tube with cuff and Murphy eye, internal diameter 5.5 mm (Ref. BRLETAN55C02 / ETAN55C02), is the airway solution that anaesthesia, emergency and intensive care departments need to ensure positive-pressure ventilation and administration of anaesthesia when a ventilation face mask cannot be used. Manufactured in medical-grade polyvinyl chloride (PVC), it offers durability, controlled flexibility and biocompatibility for critical procedures. It is supplied in a box of 10 units, designed to keep hospital stock always available in high-turnover areas such as intubation trolleys, ICU bays and operating theatres.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is inserted through the mouth, passes through the glottis and is placed in the trachea to conduct gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen against the tube: it prevents gas leaks, prevents aspiration of secretions and stabilises the device during mechanical ventilation. The Murphy eye, a lateral opening located in the distal area, acts as a safety route: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening, preventing total occlusion. The radiopaque line and depth scale allow radiographic verification of correct placement. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the manufacturer’s catalogue:
| Parameter | Specification |
|---|---|
| Manufacturer reference | ETAN55C02 / BRLETAN55C02 |
| Type | Oral (orotracheal) endotracheal tube, oral/nasal route, with cuff and Murphy eye |
| Internal diameter (ID) | 5.5 mm |
| Material | Medical-grade polyvinyl chloride (PVC), latex-free |
| Sleeve | Yes, with pilot balloon and self-sealing valve |
| Murphy eye | Present (distal lateral safety opening) |
| Connector | 15 mm standard (ISO 5356-1), compatible with ISO circuits |
| Marking | Radiopaque line and depth scale |
| Use | Single-use (sterile) |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Available references (ETAN series, orotracheal tubes with cuff and Murphy eye): documented range of sizes, all with the same configuration and supplied in boxes of 10 units:
| Internal diameter (ID) | Reference (box of 10 units) |
|---|---|
| 2.5 mm | ETAN25C02 |
| 3.5 mm | ETAN35C02 |
| 4.5 mm | ETAN45C02 |
| 5.0 mm | ETAN50C02 |
| 5.5 mm | ETAN55C02 (this product) |
| 6.5 mm | ETAN65C02 |
| 7.5 mm | ETAN75C02 |
| 8.5 mm | ETAN85C02 |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the manufacturer’s declaration of conformity and CE marking on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The references ETAN55C02 and BRLETAN55C02 are manufacturer codes within the ETAN series of orotracheal tubes with cuff; no exact reference equivalence with other brands should be declared without technical verification. There is no equivalence table validated by the manufacturer for this reference; consult the technical department at Cahnos before using this reference as an equivalence in tenders or bids.
Comparable at category level (not interchangeable 1:1): by clinical indication (endotracheal tube with cuff and Murphy eye, ID 5.5 mm) it is comparable to tubes from lines such as Rüsch® and Sheridan® (Teleflex), Shiley™ (Medtronic), DEAS S.r.l. or BOENMED. These brands do not publish a validated equivalence table for this code: the outer diameter (OD), total length, geometry and cuff material may differ, so each data sheet must be compared before substituting a specific product.
Comparable within the Cahnos catalogue (same ID 5.5 mm, other configurations):
| Reference | Description |
|---|---|
| ETAN55002 | Oral endotracheal tube without cuff with Murphy eye, ID 5.5 mm |
| ETA055C02A2 | Reinforced oral endotracheal tube with cuff and Murphy eye, ID 5.5 mm |
| ETAM55C02A1 | Reinforced oral endotracheal tube with cuff, guide and Murphy eye, ID 5.5 mm |
| ETPO55C02 | Preformed oral endotracheal tube with cuff, ID 5.5 mm |
| ETPN55C02 | Preformed nasal tracheal tube with cuff and Murphy eye, ID 5.5 mm |
5. Selection tips and variants of interest
Size selection (usual use in clinical practice, not manufacturer specification): the 5.5 mm ID size with cuff is intended for older paediatric patients, adolescents or adults with a reduced airway size. The final choice should be based on the department’s protocol and the patient’s anaesthetic assessment (age, weight and estimated airway size).
Cuff pressure: inflate through the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise tracheal mucosal damage; monitor with a manometer if available in the department.
Pre-intubation verification: check the integrity of the tube, patency of the Murphy eye, correct cuff inflation and secure attachment of the standard 15 mm connector. Single-use product: do not re-sterilise or reuse.
Variants of interest: if you need another size, the ETAN series with cuff covers from 2.5 mm to 8.5 mm (ETAN25C02 to ETAN85C02), from paediatric patients to tall adults. For procedures with a risk of kinking or external compression, consider the reinforced tubes (ETA055C02A2, ETAM55C02A1); for head and neck surgery or special positions, consult the preformed tube lines (ETPO55C02, ETPN55C02). Consult our technical-commercial team at Cahnos for reference approval and configuration of the most suitable size stock for your department.




Reviews