We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Orotracheal Endotracheal Tube with Cuff and Murphy Eye – ID 5.5 mm | Medical-Grade PVC, Sterile, Single-Use (Ref. BRLETAN55C02) | Box of 10 units

2,78 €

Orotracheal endotracheal tube (oral/nasal) with cuff and Murphy eye of internal diameter 5.5 mm, made of medical-grade polyvinyl chloride (PVC) and latex-free. Its cuff with pilot balloon and self-sealing valve ensures an airtight seal during positive-pressure ventilation and anaesthesia administration, while the Murphy eye maintains an alternative ventilation pathway if the distal lumen becomes obstructed. It includes a standard 15 mm connector (ISO 5356-1), a radiopaque line and a depth scale for radiographic position control. Single-use device, sterile, supplied in a box of 10 units: the ideal solution for anaesthesia, emergency and intensive care.

In stock

International shipping. Import duties and taxes are payable by the recipient.

Reference
BRLETAN55C02

Description

1. Introduction

The orotracheal endotracheal tube with cuff and Murphy eye, internal diameter 5.5 mm (Ref. BRLETAN55C02 / ETAN55C02), is the airway solution that anaesthesia, emergency and intensive care departments need to ensure positive-pressure ventilation and administration of anaesthesia when a ventilation face mask cannot be used. Manufactured in medical-grade polyvinyl chloride (PVC), it offers durability, controlled flexibility and biocompatibility for critical procedures. It is supplied in a box of 10 units, designed to keep hospital stock always available in high-turnover areas such as intubation trolleys, ICU bays and operating theatres.

2. Technical explanation of the device and procedure

In orotracheal intubation, the tube is inserted through the mouth, passes through the glottis and is placed in the trachea to conduct gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen against the tube: it prevents gas leaks, prevents aspiration of secretions and stabilises the device during mechanical ventilation. The Murphy eye, a lateral opening located in the distal area, acts as a safety route: if the main lumen were obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening, preventing total occlusion. The radiopaque line and depth scale allow radiographic verification of correct placement. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.

3. Technical Specifications

The specifications listed below correspond to the technical data published for this reference in the manufacturer’s catalogue:

Parameter Specification
Manufacturer reference ETAN55C02 / BRLETAN55C02
Type Oral (orotracheal) endotracheal tube, oral/nasal route, with cuff and Murphy eye
Internal diameter (ID) 5.5 mm
Material Medical-grade polyvinyl chloride (PVC), latex-free
Sleeve Yes, with pilot balloon and self-sealing valve
Murphy eye Present (distal lateral safety opening)
Connector 15 mm standard (ISO 5356-1), compatible with ISO circuits
Marking Radiopaque line and depth scale
Use Single-use (sterile)
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units

Available references (ETAN series, orotracheal tubes with cuff and Murphy eye): documented range of sizes, all with the same configuration and supplied in boxes of 10 units:

Internal diameter (ID) Reference (box of 10 units)
2.5 mm ETAN25C02
3.5 mm ETAN35C02
4.5 mm ETAN45C02
5.0 mm ETAN50C02
5.5 mm ETAN55C02 (this product)
6.5 mm ETAN65C02
7.5 mm ETAN75C02
8.5 mm ETAN85C02

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the manufacturer’s declaration of conformity and CE marking on each supplied batch before use in procedures.

4. Equivalences and Cross-References

The references ETAN55C02 and BRLETAN55C02 are manufacturer codes within the ETAN series of orotracheal tubes with cuff; no exact reference equivalence with other brands should be declared without technical verification. There is no equivalence table validated by the manufacturer for this reference; consult the technical department at Cahnos before using this reference as an equivalence in tenders or bids.

Comparable at category level (not interchangeable 1:1): by clinical indication (endotracheal tube with cuff and Murphy eye, ID 5.5 mm) it is comparable to tubes from lines such as Rüsch® and Sheridan® (Teleflex), Shiley™ (Medtronic), DEAS S.r.l. or BOENMED. These brands do not publish a validated equivalence table for this code: the outer diameter (OD), total length, geometry and cuff material may differ, so each data sheet must be compared before substituting a specific product.

Comparable within the Cahnos catalogue (same ID 5.5 mm, other configurations):

Reference Description
ETAN55002 Oral endotracheal tube without cuff with Murphy eye, ID 5.5 mm
ETA055C02A2 Reinforced oral endotracheal tube with cuff and Murphy eye, ID 5.5 mm
ETAM55C02A1 Reinforced oral endotracheal tube with cuff, guide and Murphy eye, ID 5.5 mm
ETPO55C02 Preformed oral endotracheal tube with cuff, ID 5.5 mm
ETPN55C02 Preformed nasal tracheal tube with cuff and Murphy eye, ID 5.5 mm

5. Selection tips and variants of interest

Size selection (usual use in clinical practice, not manufacturer specification): the 5.5 mm ID size with cuff is intended for older paediatric patients, adolescents or adults with a reduced airway size. The final choice should be based on the department’s protocol and the patient’s anaesthetic assessment (age, weight and estimated airway size).

Cuff pressure: inflate through the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise tracheal mucosal damage; monitor with a manometer if available in the department.

Pre-intubation verification: check the integrity of the tube, patency of the Murphy eye, correct cuff inflation and secure attachment of the standard 15 mm connector. Single-use product: do not re-sterilise or reuse.

Variants of interest: if you need another size, the ETAN series with cuff covers from 2.5 mm to 8.5 mm (ETAN25C02 to ETAN85C02), from paediatric patients to tall adults. For procedures with a risk of kinking or external compression, consider the reinforced tubes (ETA055C02A2, ETAM55C02A1); for head and neck surgery or special positions, consult the preformed tube lines (ETPO55C02, ETPN55C02). Consult our technical-commercial team at Cahnos for reference approval and configuration of the most suitable size stock for your department.

Additional information

Manufacturer

Oscar Boscarol S.r.l.

Manufacturer reference

ETAN55C02

Alternative reference

BRLETAN55C02

Product type

Orotracheal endotracheal tube with cuff and Murphy eye

Access route

Oral (orotracheal); compatible with nasal route

Inner diameter

5.5 mm

Material

Medical-grade polyvinyl chloride (PVC)

Sleeve

Yes, with pilot balloon and self-sealing valve

Connector

15 mm standard (ISO 5356-1)

Marking

Radiopaque line and depth scale

Use

Single-use (sterile)

Sterilisation

Sterile, individual packaging

Regulatory standard

ISO 5361 (tracheal tubes and connectors)

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Presentation

Box of 10 units

Latex

Latex-free

Ojo murphy

With Murphy's eye

Documentation

Reviews

There are no reviews yet.

Be the first to review “Orotracheal Endotracheal Tube with Cuff and Murphy Eye – ID 5.5 mm | Medical-Grade PVC, Sterile, Single-Use (Ref. BRLETAN55C02) | Box of 10 units”

Your email address will not be published. Required fields are marked *