We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Preformed Nasal Tracheal Tube with Cuff and Murphy Eye – ID 3.5 mm | Medical PVC, Single-Use, Box of 10 units (SKU ETPN35C02)

36,45 €

Preformed nasal tracheal tube with cuff and Murphy eye, ID 3.5 mm (SKU ETPN35C02), manufactured from medical-grade polyvinyl chloride (PVC) and single-use. Its preformed nasal curvature follows the anatomy of the airway, facilitates tube fixation and keeps the ventilation circuit away from the surgical field, while the sealing cuff ensures positive-pressure ventilation without significant leaks. Includes Murphy eye, pilot balloon with self-sealing valve, radiopaque line, depth scale and standard 15 mm connector compatible with ISO circuits. Indicated for administration of anaesthesia and mechanical ventilation when a face mask is not viable. Presentation in a box of 10 units, ideal for anaesthesia, emergency and intensive care.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETPN35C02

Description

1. Introduction

The Preformed Nasal Tracheal Tube with Cuff and Murphy Eye, ID 3.5 mm (SKU: ETPN35C02) is a single-use airway device designed to ensure safe, rapid and reproducible nasotracheal intubation in anaesthesia, intensive care and emergency care. Its preformed geometry and sealing cuff provide stability and patient comfort, facilitate correct positioning in the nasopharynx and reduce the risk of accidental displacement during ventilation. It is supplied in a box of 10 sterile units, ideal for maintaining a continuous stock in the operating theatre, NICU (neonatal intensive care units) and emergency services.

2. Technical explanation of the device and procedure

In nasotracheal intubation, the tube is inserted through one of the nostrils, passes through the nasopharynx, the glottis and is placed in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The preformed curve follows the anatomy of the upper airway: it facilitates tube fixation, minimises tissue trauma and prevents the circuit from interfering with the surgical field in oral, maxillofacial, ENT and ophthalmic surgery.

The cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks. The Murphy eye, a distal lateral opening, ensures an alternative gas passage if the tube tip becomes obstructed (by secretions or by the bevel resting against the tracheal wall). The continuous radiopaque line and depth scale allow radiographic confirmation of correct placement. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.

3. Technical Specifications

The main technical features of the tube are as follows:

Parameter Specification
Reference ETPN35C02 (own code Cahnos)
Type Preformed nasal tracheal tube (RAE/AGT type) with cuff and Murphy eye
Access route Nasal (nasopharyngeal), preformed curvature
Internal diameter (ID) 3.5 mm
Material Medical-grade polyvinyl chloride (PVC), transparent and thermosensitive, latex-free
Sleeve Yes, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Connector 15 mm standard, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque line and depth scale
Latex Latex-free
Use Single-use (sterile)
Indication Positive pressure ventilation and anaesthesia administration when a ventilation face mask is not viable
Presentation Box of 10 units

Note: the outer diameter (OD) and total length of the 3.5 mm size could not be verified in official public sources; they remain pending confirmation with the manufacturer before use in tendering or stock replacement.

Other sizes in the same family (ETPN series, same design and presentation, confirmed in the Cahnos catalogue):

Inner diameter SKU (box of 10 units)
3.0 mm ETPN30C02
3.5 mm ETPN35C02 (this product)
4.5 mm ETPN45C02
5.0 mm ETPN50C02
5.5 mm ETPN55C02
6.5 mm ETPN65C02
7.5 mm ETPN75C02

This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETPN35C02 is own code of Cahnos for this generic reference of preformed nasal PVC tube with cuff and Murphy eye; it must not be confused with the official part number of any specific manufacturer, therefore an exact reference equivalence cannot be declared, nor is there a manufacturer-validated equivalence table. Consult the Cahnos technical department before using this reference in tender documents or tenders.

Comparable at category level (not 1:1 interchangeable): the Rüsch® AGT Nasal Preformed Cuffed ETT line from Teleflex, reference 111781035 (size 3.5, box of 10), has been verified in the official Teleflex catalogue, responding to the same indication and general geometry (nasal preformed, with cuff and Murphy eye, paediatric). It differs in material (thermosensitive PVC Ruschelit®), length and cuff design, so it must be checked against the manufacturer’s technical data sheet before any use in tendering.

Comparable by category, without 1:1 verification: the preformed nasal tubes with cuff and Murphy eye from the Shiley™ RAE nasal line with TaperGuard™ cuff (Medtronic) and generic import series (BOENMED, Greetmed, etc.), with PVC low-pressure cuff, Murphy eye, 15 mm connector and radiopaque line, but with slight differences in geometry, length or inflation pressure.

Confirmed in Cahnos’ own catalogue: the rest of the diameters in the ETPN series (see table) share design and presentation; only the internal diameter changes. For the same 3.5 mm size, the comparable oral configurations by category are ETAN35C02 (oral endotracheal tube with cuff and Murphy eye) and ETPO35C02 (preformed oral endotracheal tube). There is no manufacturer-validated equivalence table; consult the Cahnos technical department before using this reference in tender documents or tenders.

5. Selection tips and variants of interest

Selection by patient (usual use in clinical practice, not manufacturer specification): the ID 3.5 mm size with cuff is commonly used in paediatric patients of approximately 3–6 years, in small airways or in adults with a narrow airway; the final choice must always be based on the service protocol and anaesthetic assessment (age, weight and estimated airway size).

Cuff pressure: inflate via the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual range in clinical practice) to minimise tracheal mucosal damage; monitor with a manometer if the department has one.

Preferred indications: oral, maxillofacial, otorhinolaryngological and ophthalmic surgery, where it is important to keep the circuit out of the operative field, as well as mechanical ventilation in intensive care.

Catalogue variants of interest: if you need another size, the ETPN series covers from 3.0 mm to 7.5 mm (ETPN30C02 to ETPN75C02). For oral access of the same diameter, the ETPO series (oral preformed) or the ETAN series (standard with cuff) is available. For intubation requiring resistance to kinking or frequent repositioning, consider the spiral-reinforced tubes in the intubation section of Cahnos. Contact the technical department of Cahnos for samples, volume conditions and hospital supply lead times.

Additional information

Material

Medical-grade polyvinyl chloride (PVC), transparent and thermosensitive, latex-free

Inner diameter

3.5 mm

Access type

Nasal (nasopharyngeal), preformed RAE/AGT-type curvature

Sleeve

Yes, with pilot balloon and self-sealing valve

Murphy eye

Yes, distal lateral safety opening

Connector

15 mm standard, compatible with ISO circuits (ISO 5356-1)

Marking

Continuous radiopaque line and depth scale

Use

Single-use (sterile)

Sterilisation

Sterilised, individually packaged

Indications

Positive pressure ventilation and anaesthesia administration when face mask is not viable

Regulatory standard

Conforms to the requirements of ISO 5361 (verify declaration of conformity and CE marking per batch)

Presentation

Box of 10 units

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Preformed Nasal Tracheal Tube with Cuff and Murphy Eye – ID 3.5 mm | Medical PVC, Single-Use, Box of 10 units (SKU ETPN35C02)”

Your email address will not be published. Required fields are marked *