Description
1. Introduction
The PVC-coated aluminium intubation stylet, 2.0 mm size (Ref. MA2023001), is an essential tool for the safe guidance of the endotracheal tube during intubation, particularly indicated for reduced-diameter airways, such as those of neonatal and paediatric patients, as well as in difficult airway scenarios. Its design combines a malleable aluminium core with a smooth medical-grade PVC sheath, offering the professional the rigidity needed to direct the tube and the precise flexibility to adapt to the patient’s anatomy.
2. Technical explanation of the equipment
The stylet is inserted inside the endotracheal tube to provide rigidity, shape and directionality during its advance through the upper airway. The malleable aluminium core allows the tube to be preformed with the desired curvature before the manoeuvre, while the smooth PVC sheath reduces friction between the stylet and the inner wall of the tube, facilitating both insertion and removal. The round, flexible tip, with a soft distal end, minimises the risk of injury to the tracheal mucosa and behaves atraumatically during guidance. It is a reusable device for hospital use, designed for intensive care, anaesthesia, emergency and paediatrics settings.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | MA2023001 |
| Material | Malleable aluminium coated with medical-grade PVC |
| Gauge | 2.0 mm |
| Tip | Round and flexible (soft, atraumatic distal end) |
| Function | To provide rigidity and curvature to the endotracheal tube during intubation |
| Clinical application | Intubation in reduced-diameter airways (neonatal/paediatric) and difficult airway |
| Use environments | Intensive care, anaesthesia, emergency and paediatrics |
| Presentation | Box of 20 units |
Cahnos range of intubation stylets:
| Reference | Gauge | Recommended use |
|---|---|---|
| MA2023001 | 2.0 mm | Tubes with a very small lumen (neonatal) |
| MA3034001 | 3.0 mm | Paediatric endotracheal tubes |
| MA5037001 | 4.0 mm | Paediatric and small adult-size tubes |
| MA5040001 | 5.0 mm | Adult endotracheal tubes |
4. Equivalences and Cross-References
Note on the reference: the code MA2023001 is an internal distributor code (Cahnos) and does not match the official nomenclature of any manufacturer. There is no equivalence table validated by the manufacturer for this code; consult the technical department before using it in tendering or homologation.
Functional category comparison (not 1:1 interchangeable): this stylet performs the same clinical function as other tracheal intubation stylets and introducers on the market manufactured with a malleable aluminium core and smooth medical plastic sheath, such as the single-use stylets from the DEAFLUX range (Deas) with soft distal tip, the malleable aluminium intubating stylets with Parker-type PVC sheath (Mercury Medical), Formedtech-type coated aluminium stylets, SUMI-style stylets with soft tip, flexible reinforcement, latex-free and graduation marking (references 41-2500, 41-3000, 41-3500 and 41-4000, depending on size) and single-use Flex Tip-type flexible bougies. These external references are cited as a technical comparison pending confirmation with the corresponding manufacturer/distributor and not as a verified exact equivalence.
Compatibility: the 2.0 mm size is intended for endotracheal tubes with a very small internal lumen; always verify compatibility between the stylet diameter and the internal diameter of the tube before replacing one reference with another.
5. Selection tips and variants of interest
Select the stylet according to the internal diameter of the endotracheal tube and the patient’s size: for very small sizes and neonatal patients use the 2.0 mm model (Ref. MA2023001); for paediatric tubes, the 3.0 mm (Ref. MA3034001) or 4.0 mm (Ref. MA5037001); and for adult tubes, the 5.0 mm (Ref. MA5040001). It can be combined with the range of endotracheal tubes available in the Cahnos catalogue, such as the ENDOSID Magill tubes without cuff in reduced sizes (Refs. 843020 and 843030), to ensure safe, rapid and atraumatic intubation. For high-volume orders or homologation requirements, contact our technical-commercial team.