Description
1. Complete percutaneous tracheostomy kit with subglottic suction
The percutaneous kit Ref. TP50-08 is the complete solution for establishing percutaneous tracheal access in the critically ill adult patient, incorporating a standard 8 mm cannula with fixed flange and dedicated subglottic suction lumen, a feature especially valued in intensive care units for its role in preventing ventilator-associated pneumonia (VAP).
All the material required for the procedure is supplied in a single sterile, ready-to-use kit: one order, one code and the guarantee that the team has all the instruments with full traceability. Preparation time is reduced, the risk of forgetting material is minimised and standardisation of the process in the ICU, emergency department and operating theatre is facilitated.
2. Technical explanation of the equipment and procedure
Percutaneous tracheostomy allows a surgical airway to be established by puncture and progressive dilatation of the stoma, without the need to move the critically ill patient. This kit is indicated for standard tracheostomy, cricothyrotomy, coniotomy or laryngotomy in adult patients, with the cannula guided through the stoma using the guide catheter and standard introducer, which maintains the tube position during insertion until correct placement in the trachea.
The cannula incorporates an additional subglottic suction lumen with an outlet above the cuff, allowing accumulated secretions in the subglottic space to be aspirated and reducing the risk of contaminated micro-aspiration into the lower airway. The fixed cervical flange, flexible and made of transparent plastic, facilitates stable fixation of the device and visualisation of the stoma; the adjustable fixation band with Velcro closure and the 9 × 9 cm tracheal compress complete stoma care and patient comfort.
3. Technical specifications and kit contents
Kit contents:
| Component | Specification |
|---|---|
| Tracheostomy tube | Standard 8 mm cannula with cuff, fixed flange and subglottic suction lumen |
| Tube introducer | Standard, for safe insertion into the stoma |
| Guide catheter | For guiding the tube during placement |
| Fixation band | Adjustable, with Velcro closure |
| Lubricating gel | Sterile sachet |
| Tracheal compress | 9 × 9 cm |
Technical parameters:
| Parameter | Value |
|---|---|
| Inner diameter of cannula | 8.0 mm |
| Flange type | Fixed, flexible, in transparent plastic |
| Subglottic suction | Yes, dedicated lumen |
| Cuff (balloon) | Low pressure |
| Connector | Universal 15 mm (15M) |
| Sterilisation | Ethylene oxide (ETO), process validated according to EN 11135-1; residuals compliant with ISO 10993-7 |
| Presentation | Sterile, individually packaged (Tyvek® pouch bonded to PA-PE film in accordance with EN ISO 11607-1 and EN ISO 11607-2) |
| Use | Single-use, disposable |
| Materials | Latex-free and phthalate-free |
| Classification | Medical device with CE marking, class IIa |
| Indication | Percutaneous tracheostomy, cricothyrotomy, coniotomy or laryngotomy |
| Storage | Between -10 and +45 °C, in a cool, dry place away from heat sources |
Family of percutaneous kits with fixed flange and subglottic suction (TP50 series):
| Reference | Diameter (I.D.) | Flange | Subglottic suction |
|---|---|---|---|
| TP50-07 | 7.0 mm | Fixed | Yes |
| TP50-08 (this product) | 8.0 mm | Fixed | Yes |
| TP50-09 | 9.0 mm | Fixed | Yes |
4. Equivalences and Cross-References
Subglottic suction integrated into percutaneous tracheostomy cannulas is a widely available feature on the market. The best-known references are listed below, classified according to the level of verification achieved; none should be treated as an exact 1:1 equivalent:
- Comparable at category level: TRACOE twist plus with cuff and subglottic suction device (P cannulas from the TRACOE percutan/experc percutaneous kits, sizes 07-10). Same subglottic suction function at the deepest point, above the cuff, but from another manufacturer and with a different component configuration: not interchangeable 1:1.
- Comparable at category level: tracheostomy cannulas with subglottic suction lumen such as Medtronic Shiley TTS or Cook Medical percutaneous dilatation sets (Ciaglia/Bailey technique). Same general clinical indication, different design, material and presentation: not interchangeable 1:1.
- Within Cahnos’s own catalogue: reference TP90-38 (8 mm Ciaglia kit with fixed flange and subglottic suction) shares the diameter and feature, but also incorporates the complete percutaneous dilatation kit with 38 Fr conical dilator and guidewire: different features, not interchangeable for procedure purposes. Reference TP02-38 offers the same fixed-flange cannula with suction in 8 mm without the remaining kit components.
- Possible reference from the same series: TP30-08 presents an equivalent kit configuration (cannula with cuff, fixed cervical flange, 9 × 9 cm tracheal compress and lubricating gel); internal validation is pending to confirm whether it is the same product under a previous reference.
There is no manufacturer-validated equivalence table allowing this reference to be cross-referenced with specific codes from other suppliers; it is recommended to consult Cahnos’s technical department before using this datasheet in a tendering process or stock replacement.
5. Selection tips and variants of interest
To choose the right kit, consider the cannula diameter according to the patient and the clinical indication: the 7 mm variant (TP50-07) is reserved for adults of smaller build or more limited anatomies; the 8 mm (TP50-08), this product, is the reference option for adults of medium build, and the 9 mm (TP50-09) is indicated for adults of medium-large build or with a need for greater ventilatory flow.
Subglottic suction in this series is especially recommended when prolonged mechanical ventilation is anticipated, due to its role in preventing ventilator-associated pneumonia. If an adjustable flange or a kit with full dilatation technique (Ciaglia with 38 Fr conical dilator and guidewire) is preferred, see the rest of the percutaneous kit family available in the store (TP90 and TP02 series). All kits in the family are single-use: dispose of them after the procedure as healthcare waste in accordance with current local regulations.





Reviews
There are no reviews yet.