Description
1. Commercial Introduction
The uncuffed endotracheal tube of Ø 4.0 mm (Ref. 57641) is the airway solution that anaesthesia, intensive care, emergency and paediatric departments need when ventilation with a reduced calibre is required. Made of transparent, thermosensitive, latex-free medical-grade PVC, it offers a thin-walled body that adapts smoothly to the patient’s anatomy while maintaining lumen patency. Its presentation in a box of 100 units, individually packaged and sterile, makes it the ideal format for restocking the intubation trolley and high-turnover hospital consumables.
2. Technical explanation of the product and procedure
In orotracheal intubation, the tube is introduced orally under laryngoscopic vision, passes through the glottis and sits in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. As it has no cuff, sealing is achieved by the fit of the tube’s calibre against the tracheal wall, so the correct size selection is crucial to minimise leaks and avoid mucosal damage.
This model features bull-nose (rounded) tips, which facilitate atraumatic advancement through the glottic structures; smooth Murphy eyes, which act as a safety ventilation route if the main lumen becomes obstructed at the distal end; and a thermosensitive PVC material resistant to kinking (kink-resistant), which reduces tube collapse during head movement or circuit kinking. The break-resistant radiopaque lines allow radiographic verification of the tube position. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the data published by the manufacturer for this reference:
| Parameter | Specification |
|---|---|
| Manufacturer reference | 57641 (SKU GM57641) |
| Type | Uncuffed endotracheal tube |
| Diameter | Ø 4.0 mm |
| Tube length | 20.5 cm |
| Material | Medical-grade PVC, thermosensitive, latex-free |
| Tip | Bull-nose type (rounded, atraumatic) |
| Murphy eye | Present (smooth Murphy eyes) |
| Marking | Radiopaque lines resistant to breakage |
| Sterility | Sterile, individually packaged |
| Use | Single-use, non-reusable |
| Presentation | Box of 100 units (minimum order) |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920212 |
4. Equivalences and Cross-References
Reference 57641 is an official manufacturer code. For this configuration (uncuffed endotracheal tube with Murphy eye, Ø 4.0 mm) the following references are offered as comparable at category level (not interchangeable 1:1) and must be compared specification by specification, especially in outer diameter, total length and tip type, before substitution:
| Manufacturer / Line | Reference | Description | Degree of correspondence |
|---|---|---|---|
| Asid Bonz (ENDOSID®) | 843040 / 84 30 400 | Uncuffed endotracheal tube with Murphy eye, ID 4.0 mm, transparent PVC, 15 mm connector | Comparable by category (without spiral reinforcement) |
| P. J. Dahlhausen | 44.000.11.040 | Magill-type uncuffed endotracheal tube without stylet, ID 4.0 mm, PVC, sterile | Comparable by category |
| Asid Bonz (ENDOSID®) | 84 96 400 | Magill-type spiral-reinforced uncuffed endotracheal tube, ID 4.0 mm, with insertion stylet | Comparable by category (with reinforcement and stylet) |
Note: no equivalence table validated by the manufacturer is available for 1:1 substitution. It is recommended to consult the technical department of Cahnos before using these references in tenders or stock substitution.
5. Selection tips and variants of interest
The 4.0 mm diameter calibre is intended for paediatric patients and reduced-calibre airways. As a general clinical practice guideline (not a manufacturer specification), in the paediatric range endotracheal tubes of 3.0 to 5.5 mm are used according to age, weight and anaesthetic assessment; always select the largest size compatible with the patient’s anatomy and the centre’s protocol. As it is an uncuffed tube, the size selection determines the seal: an appropriate calibre minimises leaks and avoids mucosal damage.
The uncuffed configuration is the appropriate option for procedures of limited duration and for patients in whom it is preferred to avoid cuff inflation. If your protocol requires an airtight seal or prolonged ventilation, consider the cuffed alternatives in the catalogue; if you need greater resistance to kinking, consult the spiral-reinforced tubes. Pre-intubation verification: check the integrity of the tube, the patency of the Murphy eye and the sterility expiry date. Single-use device: do not re-sterilise or reuse. For volume conditions, samples or hospital supply lead times, contact the technical-commercial department of Cahnos.




Reviews