We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 8.5 mm | Medical-Grade PVC, Single-Use | Ref. ETA085C02A2 | Box of 10 units

99,80 €

Reinforced oral endotracheal tube with cuff and Murphy eye, ID 8.5 mm (Ref. ETA085C02A2), manufactured from medical-grade polyvinyl chloride (PVC), transparent and latex-free. Its anti-kink helical spiral keeps the airway patent and stable during head and neck movements, external compression or complex surgical positions, making it the usual choice in anaesthesia, emergency and intensive care for positive-pressure ventilation when a face mask is not viable. It includes a sealing cuff with pilot balloon and self-sealing valve, a universal 15 mm connector (ISO 5356-1), a radiopaque line and depth graduation. Supplied in a box of 10 units, sterile and single-use; verify the CE/MDR marking of each batch before use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETA085C02A2

Description

1. Introduction

The reinforced oral endotracheal tube with cuff and Murphy eye, 8.5 mm (Ref. ETA085C02A2) is the airway solution that anaesthesia, emergency and intensive care services need when face mask ventilation is not viable. Manufactured in medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the resistance of the anti-kink helical reinforcement with the airtight sealing of the cuff and the safety of the Murphy eye, offering a patent and stable airway during critical procedures. It is presented in a box of 10 individually packaged units, designed for the intubation trolley and high-turnover hospital consumables, guaranteeing a uniform and reliable standard in each procedure.

2. Technical explanation of the equipment and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and is placed in the trachea, below the vocal cords, conducting the gases from the ventilator, the anaesthesia circuit or the resuscitation bag to the lungs. The helical reinforcement integrated into the PVC wall prevents collapse of the tube under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial, thyroid, prone positioning and complex surgical positions.

The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during positive-pressure ventilation. The Murphy eye, a distal lateral opening, acts as a safety pathway: if the tip of the tube rests against the tracheal or bronchial wall, respiratory flow continues through that opening and occlusion is never total. The universal 15 mm connector (ISO 5356-1), the radiopaque line and the depth graduation allow connection to the circuit and radiographic verification of position. It is a single-use device: after each patient it must be discarded to avoid any risk of cross-infection.

3. Technical Specifications

The specifications set out below correspond to the technical data published for this reference in the Cahnos catalogue:

Parameter Specification
Reference (SKU) ETA085C02A2 (distributor’s own code Cahnos; ETA series: reinforced with cuff, without guide)
Type Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced
Access route Oral (orotracheal)
Internal diameter (ID) 8.5 mm (adult size / large adult size)
Reinforcement Anti-kink helical spiral integrated into the tube wall
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Sealing (cuff inflation), with pilot balloon and self-sealing valve
Murphy eye Present (distal lateral safety opening)
Tip Atraumatic, rounded and gently bevelled
Connector Universal 15 mm, compatible with ISO circuits (ISO 5356-1)
Marking Radiopaque contrast line and depth graduation
Sterilisation Ethylene oxide (EO), sterile, individually packaged
Use Single-use, non-reusable
Indication Positive pressure ventilation and anaesthesia administration when face mask is not viable
Presentation Box of 10 units
Indicative population Adult / large adult
Regulatory standard ISO 5361 (tracheal tubes); connector ISO 5356-1; verify CE/MDR marking of each batch

Range of sizes confirmed in Cahnos (ETA…C02A2 series, reinforced with cuff and Murphy eye, without guide):

Reference Internal diameter (ID) Indicative patient
ETA080C02A2 8.0 mm Adult
ETA085C02A2 (this product) 8.5 mm Adult / large adult

Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthetic equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity, the CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.

4. Equivalences and Cross-References

The reference ETA085C02A2 is a catalogue-specific code of Cahnos (ETA series: reinforced oral tracheal tubes with cuff, without guide) and must not be confused with the official reference number of any specific manufacturer. To date, there is no manufacturer-validated equivalence table for this reference, so the following options are classified as comparable at category level (not interchangeable 1:1), pending technical verification against each manufacturer’s official datasheet:

Reference / Line Description Degree of correspondence
849085 / 849085-M (Endosid® / Asid Bonz) Spiral reinforced endotracheal tube with Murphy eye and high-volume, low-pressure cuff, ID 8.5 mm; the -M variant includes an intubation stylet Comparable by category; verify inflation system, outer diameter and guide
44.000.20.085 (P. J. Dahlhausen) Reinforced endotracheal tube with cuff (Woodbridge type), DI 8.5 mm, PVC, sterile Comparable by category; verify presence of Murphy eye and connector
44.000.10.085 (P. J. Dahlhausen) Magill-type endotracheal tube with cuff and Murphy eye, DI 8.5 mm, without spiral reinforcement Comparable by category; differs in reinforcement (without helical armouring)
Rüsch® / Sheridan (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical Reinforced cuffed endotracheal tube lines on the market Comparable by category; not interchangeable 1:1 without verification of datasheet and IFU

Fields to be contrasted before comparing: internal diameter (8.5 mm), material (medical-grade PVC), cuff type (high volume / low pressure), presence of Murphy eye, 15 mm connector and helical reinforcement. There is no manufacturer-validated equivalence table for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids or as a direct stock replacement for other brands.

Comparable by category within the Cahnos catalogue (same size 8.5 mm, not interchangeable 1:1):

Reference Description Key difference
ETAM85C02A1 Oral reinforced tube with cuff, insertion guide and Murphy eye, DI 8.5 mm Adds included insertion stylet
ETA085002A2 Oral reinforced tube without cuff, with Murphy eye, DI 8.5 mm Without cuff
ETAN85C02 Oral tube with cuff and Murphy eye, DI 8.5 mm Without helical reinforcement
ETSL85C02 Oral tube with cuff and subglottic suction lumen, DI 8.5 mm Adds subglottic suction for prevention of VAP
ETPO85C02 Preformed tracheal tube (oral/nasal) with cuff, DI 8.5 mm Preformed geometry, different approach route

5. Selection tips and variants of interest

Size selection: the 8.5 mm ID is aimed at adult patients of medium-to-large build. As a general clinical practice guideline (not a manufacturer specification), tubes of 7.0 to 9.0 mm are used in adults depending on body habitus and airway, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.

Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the service has one.

Variants of interest: if insertion assistance is required, consider Ref. ETAM85C02A1 (same size, with guide); if the procedure is short and the balloon is to be avoided, Ref. ETA085002A2 (reinforced without cuff). Complete the intubation trolley stock with the adjacent sizes in the range (ETA080C02A2 and ETAM80C02A1) and, in the event of risk of ventilator-associated pneumonia (VAP) in prolonged intubations, consult the lines with subglottic suction lumen (ETSL85C02). Single-use product: do not re-sterilise or reuse. Contact the technical-commercial department of Cahnos for samples, volume conditions and reference approval for your tender.

Additional information

Product type

Reinforced oral (orotracheal) endotracheal tube, with cuff

Access route

Oral (orotracheal)

Inner diameter

8.5 mm

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Reinforcement

Anti-kink helical spiral integrated into the tube wall

Sleeve

Sealing, cuff inflation with pilot balloon and self-sealing valve

Murphy eye

Present, distal lateral safety orifice

Connector

Universal 15 mm (ISO 5356-1)

Radiopacity

Radiopaque line and depth graduation

Sterilisation

Ethylene oxide (EO), sterile, individual packaging

Use

Single-use, non-reusable

Presentation

Box of 10 units

Indicative population

Adult / large adult

Regulatory standard

ISO 5361; connector ISO 5356-1; verify CE/MDR marking of each batch

Reviews

There are no reviews yet.

Be the first to review “Reinforced Oral Endotracheal Tube with Cuff and Murphy Eye – ID 8.5 mm | Medical-Grade PVC, Single-Use | Ref. ETA085C02A2 | Box of 10 units”

Your email address will not be published. Required fields are marked *