Description
1. Commercial Introduction
The reinforced oral endotracheal tube with cuff and Murphy eye of 6.0 mm internal diameter (Ref. ETA060C02A2) is the airway solution that anaesthesia, intensive care, emergency and resuscitation departments need when face mask ventilation is not viable. Its spiral-reinforced wall prevents kinking and collapse of the tube during patient movement, external compression or complex surgical positions, ensuring a patent lumen throughout the procedure. It is supplied in a box of 10 units, ready for restocking the intubation trolley, ICU bays and operating theatres, with a uniform, reliable and sterile standard in every use.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea, below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs via the universal 15 mm connector (ISO 5356-1).
The integrated helical reinforcement in the PVC wall resists compression, biting and kinking, making it the reference choice in head and neck surgery, ENT, maxillofacial procedures, prone positioning or frequent repositioning. The sealing cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen, allows positive-pressure ventilation without leaks and reduces the risk of suction of secretions. The Murphy eye, a lateral orifice located near the distal tip, acts as a safety route: if the main opening were obstructed by resting against the tracheal or bronchial wall, respiratory flow continues through that orifice, so occlusion is never total. The radiopaque line and depth graduation allow radiographic verification of the correct tube position.
3. Technical Specifications
Technical data corresponding to the data sheet for this reference in the Cahnos catalogue:
| Parameter | Specification |
|---|---|
| Reference (SKU) | ETA060C02A2 (distributor’s own code Cahnos; ETA family, nomenclature of the DEAFLUX line from DEAS S.r.l.) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Access route | Oral (orotracheal) |
| Internal diameter (ID) | 6.0 mm |
| Reinforcement | Anti-kink helical spiral integrated into the tube wall |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Sealing, cuff inflation with pilot balloon and self-sealing valve |
| Murphy eye | Present, distal lateral safety orifice |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO/ETO), sterile, individually packaged |
| Use | Single-use, non-reusable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 individually packaged units |
| Indicative population | Small adult / tall paediatric |
| Regulatory standard | ISO 5361 (tracheal tubes and connectors); connector according to ISO 5356-1; sterilisation according to EN ISO 11135-1 |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 and the biocompatibility standards applicable to airway devices. Verify the manufacturer’s declaration of conformity and CE/MDR marking on each supplied batch before use in procedures.
Range of sizes of the same model (ETA series, reinforced with cuff without guide) confirmed in the Cahnos catalogue:
| Reference | Internal diameter (ID) |
|---|---|
| ETA045C02A2 | 4.5 mm |
| ETA060C02A2 (this product) | 6.0 mm |
| ETA065C02A2 | 6.5 mm |
| ETA080C02A2 | 8.0 mm |
If you require an integrated insertion guide, the ETAM family (reinforced with cuff and guide) covers from 3.0 mm to 10.0 mm: ETAM30C02A1, ETAM35C02A1, ETAM45C02A1, ETAM50C02A1, ETAM55C02A1, ETAM60C02A1, ETAM65C02A1, ETAM70C02A1, ETAM75C02A1, ETAM80C02A1, ETAM85C02A1, ETAM90C02A1, ETAM95C02A1 and ETAM10C02A1.
4. Equivalences and Cross-References
Functional equivalence of category (not interchangeable 1:1). By clinical indication (reinforced oral endotracheal tube with cuff and Murphy eye, ID 6.0 mm), this product is comparable to spiral-reinforced tubes from manufacturers such as Teleflex (Rüsch® / Safety-Flex), Medtronic (Shiley™ / Mallinckrodt™), ICU Medical (Portex® Blue Line®) and Intersurgical. All these brands offer reinforced oral tubes to resist compression, but they differ in outer diameter (OD), total length, distal tip geometry and cuff characteristics, so they must be compared data sheet by data sheet and IFU before replacing a specific product.
| Reference / Line | Description | Degree of correspondence |
|---|---|---|
| 849060 (ENDOSID® / Asid Bonz) | Spiral-reinforced endotracheal tube (Magill) with high-volume low-pressure cuff and Murphy eye, 6.0 mm | Verified in the manufacturer’s official catalogue; comparable by category. Compare inflation system, outer diameter and packaging. |
| 44.000.20.060 (P. J. Dahlhausen GmbH) | Reinforced endotracheal tube with cuff, 6.0 mm, from the range 44.000.20.035–44.000.20.100 | Verified in the manufacturer’s official technical data sheet; comparable by category. Confirm presence of Murphy eye and batch packaging. |
| 118-60M (Safety-Flex, Mallinckrodt/Teleflex) | Reinforced endotracheal tube with cuff and Murphy tip, 6.0 mm, 15 mm connector | Comparable by category; pending verification of official data sheet. |
| Rüsch® / Sheridan® (Teleflex), Shiley™ (Medtronic), Portex® (ICU Medical), Intersurgical | Reinforced cuffed endotracheal tube lines on the market | Comparable by category; not interchangeable 1:1 without verification of data sheet and IFU. |
Reference ETA060C02A2 is a code specific to the Cahnos range and does not correspond to an official manufacturer part number published in public sources; it should be treated as an internal distributor reference and verified before use in tenders that require the manufacturer’s code. There is no equivalence table validated by the manufacturer for this reference; consult the technical department at Cahnos before using this reference as an equivalence in tender specifications or as a direct replacement for stock from other brands. References 849060 and 44.000.20.060 are cited as a functional category comparison verified in official sources from the respective manufacturers, never as an exact equivalence.
Comparables by category within the Cahnos catalogue in 6.0 mm ID (not interchangeable 1:1):
| Reference | Description | Key difference |
|---|---|---|
| ETAM60C02A1 | Reinforced oral endotracheal tube with cuff, insertion guide and Murphy eye, 6.0 mm ID | Includes insertion guide |
| ETA060002A2 | Reinforced oral endotracheal tube without cuff, with Murphy eye, 6.0 mm ID | Without cuff (sealed by size fit) |
| ETSL60C02 | Oral endotracheal tube with cuff and subglottic suction lumen, 6.0 mm ID | Adds subglottic suction (DEAFLUX line) |
| ETAN60C02 | Oral endotracheal tube with cuff and Murphy eye, 6.0 mm ID | Without helical reinforcement (pending confirmation) |
| ETPN60C02 | Preformed nasotracheal tube with cuff and Murphy eye, 6.0 mm ID | Preformed nasal approach (pending confirmation) |
5. Selection tips and variants of interest
Size selection (usual practice in clinical use, not a manufacturer specification): the 6.0 mm ID is intended for tall paediatric patients or small-framed adults. As a general reference, tubes of 7.0 to 9.0 mm are used in adults depending on body frame, always selecting the largest size compatible with the patient’s anatomy and the centre’s protocol.
Cuff pressure: check the integrity of the cuff, the pilot balloon and the patency of the lumen before intubation; inflate with a syringe and maintain the sealing pressure within the usual clinical range (indicative 20–30 cmH₂O; common market practice, confirm with the department’s protocol), monitoring with a manometer to minimise damage to the tracheal mucosa during prolonged ventilation.
Pre-use verification: check the patency of the Murphy eye, the secure attachment of the 15 mm connector to the circuit and the correct condition of the cuff. Single-use product: do not re-sterilise or reuse; dispose of it after removal according to the centre’s healthcare waste management protocols.
Relevant variants: if you need an insertion guide, consider Ref. ETAM60C02A1 (reinforced with cuff, same size); if intubation will be prolonged and there is a risk of ventilator-associated pneumonia (VAP), consider the series with subglottic suction lumen ETSL60C02; if a tight seal is not required, the cuffless version ETA060002A2; for nasal approaches, the preformed ETPN60C02. Complete the intubation trolley stock with the adjacent sizes of the family (ETA065C02A2 and ETAM60C02A1) and contact the technical-commercial department at Cahnos for volume pricing, samples and hospital supply lead times.




Reviews