Description
1. Introduction
The Reinforced Magill Endotracheal Tube with Cuff ENDOSID® from Medline is the reference solution for anaesthesia, resuscitation and critical care when the procedure requires stable airway fixation. Its spiral reinforcement along the tube shaft prevents bending or collapse, even during patient movement, frequent repositioning or complex surgical positions. Compatible with both oral and nasal intubation, this tube is indicated for positive-pressure ventilation and administration of general anaesthesia when face mask ventilation is not viable.
2. Technical explanation
The tube is manufactured in pre-curved PVC with a Magill-type geometry that facilitates access to the glottis and adapts better to the patient’s anatomical conditions. The wall incorporates a helical spiral reinforcement that provides resistance to kinking, maintaining airway patency against external compression or biting during mechanical ventilation.
The high-volume, low-pressure cuff provides effective sealing of the tracheal lumen while minimising pressure on the mucosa, while the atraumatic tip reduces the risk of injury during insertion. For optimal control of intubation depth, the tube incorporates a proximal double-ring mark and a graduation along the tube, allowing clinical verification of the correct position. The proximal end features a universal 15 mm connector compatible with ISO circuits (ISO 5356-1), and the system includes a syringe for balloon inflation. It is a single-use device, indicated to avoid the risk of cross-infection.
3. Technical specifications and available references
General characteristics
| Parameter | Specification |
|---|---|
| Tube type | Reinforced (anti-kink spiral), Magill-type curvature |
| Sleeve | Yes, high volume and low pressure |
| Stylet | No |
| Murphy eye | No |
| Syringe | Yes, included |
| Access route | Oral and nasal |
| Material | Medical-grade pre-curved PVC |
| Tip | Atraumatic |
| Marking | Double proximal ring and depth graduation |
| Connector | Universal 15 mm (ISO 5356-1) |
| Inner diameter | From 3.5 to 9 mm |
| Use | Single-use |
Available references
| Reference | Inner diameter | Units per box | Units per pack |
|---|---|---|---|
| 849540 | 4 mm | 50 | 5 |
| 849545 | 4.5 mm | 50 | 5 |
| 849555 | 5.5 mm | 50 | 5 |
| 849565 | 6.5 mm | 50 | 5 |
| 849575 | 7.5 mm | 50 | 5 |
| 849590A | 9 mm | 50 | 5 |
| 849535A | 3.5 mm | 50 | 5 |
| 849540A | 4 mm | 50 | 5 |
| 849535 | 3.5 mm | 50 | 5 |
| 849555A | 5.5 mm | 50 | 5 |
| 849545A | 4.5 mm | 50 | 5 |
| 849560A | 6 mm | 50 | 5 |
| 849550A | 5 mm | 50 | 5 |
| 849565A | 6.5 mm | 50 | 5 |
| 849570A | 7 mm | 50 | 5 |
| 849575A | 7.5 mm | 50 | 5 |
| 849580A | 8 mm | 50 | 5 |
| 849585A | 8.5 mm | 50 | 5 |
4. Equivalences and Cross-References
There is no exact equivalence table validated by the manufacturer for this reference; the following references are offered as a functional category comparison (not interchangeable 1:1) and must be checked data sheet by data sheet (external diameter, length, distal geometry and inflation system) before any substitution:
| Manufacturer / Line | Indicative reference | Observations |
|---|---|---|
| Teleflex (Rüsch® / RüschFlex) | 104202-000040 (4.0 mm) | Reinforced tube with cuff and Murphy eye; comparable by category, verify configuration |
| P. J. Dahlhausen (Woodbridge) | 44.000.20.0XX (series) | Reinforced tubes with cuff and, in some sizes, integrated guide rod |
| Medtronic (Shiley™ / Mallinckrodt™) | Reinforced series with cuff | Comparable by category; check technical data sheet and IFU |
| ENDOSID® / Asid Bonz (same family with Murphy eye) | 849040 / 849040A and series 8490xx | Same line of spiral reinforcement and HVLP cuff; verify presence of Murphy eye according to reference |
Consult the technical department of Cahnos before using these references as equivalence in tenders or bids.
5. Selection tips and variants of interest
Select the size according to the patient’s anatomy and the service protocol: as a general clinical practice guideline, tubes of 7.0 to 9.0 mm are used in adults and smaller sizes in paediatrics, always choosing the largest size compatible with the airway. Before insertion, check the integrity of the cuff and pilot balloon, and control the sealing pressure within the usual clinical range (indicative 20–30 cmH₂O, confirm the centre’s protocol). This reinforced tube is especially indicated when frequent repositioning, head and neck surgery or risk of kinking are anticipated. If you require insertion assistance or an additional safety margin, consider the variants of the same family with Murphy eye or with guide available in the Cahnos catalogue. Single-use device: do not re-sterilise or reuse. Product on quotation; consult your technical-commercial representative from Cahnos for volume conditions and supply times.



Reviews
There are no reviews yet.