We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Preformed Nasal Tracheal Tube (RAE) with Low-Pressure Cuff and Murphy Eye – ID 8.0 mm (Ø ext. 10.7 mm) | Ref. ETPN80C02 | Box of 10 units, Sterile

36,45 €

Preformed nasal tracheal tube (RAE) with low-pressure cuff and Murphy eye, in medical-grade thermosensitive PVC, latex-free and phthalate-free. Inner diameter 8.0 mm, outer diameter 10.7 mm and 330 mm in length. Manufactured by DEAS (Deaflux) and distributed by Cahnos, it is a sterile (ETO) single-use device, indicated for positive pressure ventilation, administration of anaesthesia and tracheobronchial suction when a face mask is not viable. With radiopaque line, connector ISO 15 mm and double depth marker. Presentation in a box of 10 individually packaged units. Ref. ETPN80C02.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETPN80C02

Description

1. Introduction

The preformed nasal tracheal tube with cuff and Murphy eye, 8.0 mm (Ref. ETPN80C02) is an airway management device designed to ensure safe and effective ventilation in patients where ventilation with a face mask is not possible or is insufficient. Its preformed RAE (Ring-Adair-Elwyn) geometry keeps the anaesthesia circuit away from the surgical field, making it the usual choice in oral, nasal, maxillofacial, ophthalmic and otorhinolaryngological surgery. Manufactured by DEAS S.r.l. (Deaflux, Italy) and distributed in Spain by Cahnos, it complies with European standards for class IIa medical devices.

2. Technical explanation of the device

Preformed nasal tracheal tubes are inserted through the nostril and directed towards the trachea, where the low-pressure, high-volume cuff is inflated to seal the airway and allow positive-pressure ventilation without significant leaks. The preformed curve of the tube rests naturally on the patient’s forehead, minimising pressure on the nostrils and reducing the risk of kinking or accidental disconnection. The Murphy eye, a distal lateral opening, ensures ventilation remains patent even if the tip of the tube becomes occluded against the tracheal wall. The device is made of high-purity heat-sensitive PVC, which softens at body temperature to adapt to the patient’s anatomy, and includes a longitudinal radiopaque line for position verification by X-ray, a double depth marker and graduation every centimetre.

3. Technical Specifications

3.1. Technical data for model ID 8.0 mm (Ref. ETPN80C02)

Type Nasal, preformed (RAE) with cuff
Inner diameter (ID) 8.0 mm
Outer diameter (Ø ext.) 10.7 mm
Length 330 mm
Inflated balloon diameter 26 mm
Material Medical-grade heat-sensitive PVC and PE. Latex-free and phthalate-free
Sleeve Low pressure and high volume, thin and delicate walls
Murphy eye Yes, smoothly formed without sharp edges
Tip Atraumatic and rounded
Connector 15 mm in accordance with ISO 5356-1
Radiopaque line Longitudinal along the tube
Markings Double depth marker, graduation every cm and cutting indicator
Sterilisation Ethylene oxide (ETO) according to EN 11135-1; residues in accordance with ISO 10993-7
Use Single-use, disposable
Presentation Box of 10 individually packaged units (medical Kraft paper + PA/PE film according to EN ISO 11607-1/2)
Regulatory classification Medical device Class IIa (Annex IX, Directive 93/42/EEC) – Notified Body TÜV SÜD

3.2. Complete range of available sizes

Ø int. (mm) Ø ext. (mm) Length (mm) Ø balloon (mm) Reference
4.0 5.3 210 14 ETPN40C02
4.5 6.0 225 14 ETPN45C02
5.0 6.7 245 17 ETPN50C02
5.5 7.3 275 17 ETPN55C02
6.0 8.0 285 20 ETPN60C02
6.5 8.7 295 20 ETPN65C02
7.0 9.3 310 25 ETPN70C02
7.5 10.0 315 25 ETPN75C02
8.0 10.7 330 26 ETPN80C02

4. Equivalences and Cross-References

Reference clarification: the code ETPN80C02 is the distributor’s own SKU (Cahnos) for this product; the family is officially documented as ETPN40C02–ETPN80C02 according to the manufacturer DEAS S.r.l.’s technical data sheet ref. 04906-3e.doc Rev.3. It should not be confused with other lines from the same manufacturer (preformed oral tubes ETPO, tubes with subglottic suction lumen ETSL, nor Magill tubes ETAN).

Comparisons between brands (category level, not interchangeable 1:1):

  • Medtronic / Covidien Shiley™ – Nasal RAE endotracheal tube with TaperGuard™ cuff 8.0 mm (ref. 96380): comparable at category level: same nasal insertion route, RAE preformed geometry, PVC, Murphy eye and 15 mm connector. The cuff design differs (tapered TaperGuard versus low-pressure/high-volume balloon) and the manufacturer, so it is not interchangeable without clinical validation.
  • Portex™ (Smiths Medical / ICU Medical): preformed RAE endotracheal tubes with SOFT-SEAL™ cuff. Specific reference for 8.0 mm nasal pending confirmation with the manufacturer before use in tenders.
  • BOENMED® and other Asian manufacturers: preformed nasal endotracheal tubes with high-volume, low-pressure balloon, comparable by category; verify CE certifications and traceability.

There is no equivalence table validated by the manufacturer DEAS for this product; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Size selection: the ID 8.0 mm (32 Fr) is a common adult size; for smaller patients, the ETPN range is available from 4.0 mm to 7.5 mm. Always confirm the size according to the centre’s protocol and anatomical conditions.
  • Surgical use: the preformed nasal (RAE) design is the option of choice when the operative field needs to be freed (oral, maxillofacial, ophthalmic and ENT surgery). The circuit is directed over the forehead, reducing pressure on the nostrils.
  • Variants at Cahnos: if oral route is required, the preformed oral tube with balloon ETPO80C02 is the alternative from the same family; the Magill tube with cuff ETAN80C02 covers oral/nasal intubation without preformed curve; and the ETSL80C02 incorporates an additional lumen for subglottic suction during prolonged ventilation.
  • Recommended accessories: intubation guide stylet (e.g. ref. 844050, 14 channels for tubes from 5 to 10 mm), Luer syringe for balloon inflation and tube fixator. Ensure the cuff pressure remains within a safe range (usually < 25 cmH2O).
  • Handling: lubricate the distal end before insertion, verify the position after intubation with the radiopaque line and check the patency of the Murphy eye for suctioning. Single-use product: do not re-sterilise or reuse.

Additional information

Product type

Preformed nasal (RAE) with cuff

Manufacturer

DEAS S.r.l. (Deaflux)

Distributor in Spain

Cahnos S.L.

Material

Medical-grade heat-sensitive PVC and PE; latex-free and phthalate-free

Inner diameter

8.0 mm

Inflated balloon diameter

26 mm

Sleeve

Low pressure and high volume

Tip

Atraumatic and rounded

Connector

15 mm in accordance with ISO 5356-1

Radiopaque line

Longitudinal

Sterilisation

Ethylene oxide (ETO), sterile

Use

Single-use, disposable

Presentation

Box of 10 individually packaged units

Regulatory classification

Medical device Class IIa (Directive 93/42/EEC, TÜV SÜD)

Shelf life

59 months from production date

Storage

-10 °C to +45 °C, cool and dry place

Diametro mm

10.7 mm

Longitud

3.3 cm

Ojo murphy

With Murphy's eye

Reviews

There are no reviews yet.

Be the first to review “Preformed Nasal Tracheal Tube (RAE) with Low-Pressure Cuff and Murphy Eye – ID 8.0 mm (Ø ext. 10.7 mm) | Ref. ETPN80C02 | Box of 10 units, Sterile”

Your email address will not be published. Required fields are marked *