We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Oral Endotracheal Tube (Orotracheal) with Cuff and Murphy Eye – ID 3.5 mm | Medical-Grade PVC, Single-Use, Box of 10 units (Ref. ETAN35C02)

16,05 €

Single-use oral endotracheal tube with cuff and Murphy eye, internal diameter (ID) of 3.5 mm, manufactured from medical-grade polyvinyl chloride (PVC) and latex-free. Indicated for positive-pressure ventilation and administration of anaesthesia when a ventilation face mask is not feasible. Features a sealing cuff with pilot balloon and self-sealing valve, universal 15 mm connector (ISO 5356-1), radiopaque line and depth scale for radiographic position control. Presentation in box of 10 sterile units, ideal for anaesthesia, emergency, paediatrics and intensive care.

International shipping. Import duties and taxes are payable by the recipient.

Reference
ETAN35C02

Description

1. Introduction

The oral endotracheal tube with cuff and Murphy eye of DI 3.5 mm (Ref. ETAN35C02) is a single-use airway device designed to ensure safe and effective ventilation when the ventilation face mask is not viable. Made of medical-grade polyvinyl chloride (PVC), it is part of the ETAN family from Cahnos and is supplied in a box of 10 units, making it a cost-effective solution for restocking intubation carts, ICU bays, operating theatres and emergency and paediatrics departments.

2. Technical explanation of the device and procedure

In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and is placed in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The cuff, inflated via the pilot balloon with self-sealing valve, seals the tracheal lumen against the tube: it prevents gas leaks, prevents suction of secretions and stabilises the device during mechanical ventilation. The Murphy eye, a lateral opening located at the distal end, acts as a safety pathway: if the tip were obstructed by secretions or by the bevel resting against the tracheal wall, respiratory flow continues through this opening and occlusion is never total. The longitudinal radiopaque line and depth scale allow radiographic verification of correct placement. It is a single-use device: after each patient it must be discarded to avoid the risk of cross-infection.

3. Technical Specifications

Parameter Specification
Reference ETAN35C02 (own code Cahnos)
Type Oral endotracheal (orotracheal), Magill curvature, with cuff and Murphy eye
Internal diameter (ID) 3.5 mm
Material Medical-grade polyvinyl chloride (PVC), transparent, latex-free
Sleeve Yes, sealing, with pilot balloon and self-sealing valve
Murphy eye Yes, distal lateral safety opening
Connector Universal 15 mm (ISO 5356-1), compatible with ISO circuits
Marking Radiopaque line and depth scale
Use Single-use (sterile, individually packaged)
Indication Positive pressure ventilation and anaesthesia administration
Presentation Box of 10 units

Note: the outer diameter (OD) and total length of this size could not be verified in official public sources; they remain pending confirmation with the manufacturer before use in tenders or stock replacement.

ETAN range – orotracheal tubes with cuff and Murphy eye (same configuration, Cahnos references):

Internal diameter (ID) Reference (box of 10 units)
2.5 mm ETAN25C02
3.0 mm ETAN30C02
3.5 mm ETAN35C02 (this product)
4.0 mm ETAN40C02
4.5 mm ETAN45C02
5.0 mm ETAN50C02
5.5 mm ETAN55C02
6.5 mm ETAN65C02
7.0 mm ETAN70C02
7.5 mm ETAN75C02
8.0 mm ETAN80C02
8.5 mm ETAN85C02
10.0 mm ETAN10C02

This category of tracheal tubes is manufactured in accordance with the requirements of ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.

4. Equivalences and Cross-References

The SKU ETAN35C02 is Cahnos’s own code, associated with the nomenclature of the DEAFLUX line (DEAS S.r.l., Italy) of Magill tracheal tubes with cuff. It does not correspond to an official published part number of any manufacturer, so no exact reference equivalence can be declared nor is there a manufacturer-validated equivalence table; consult Cahnos’s technical department before using this reference in specifications or tenders.

Comparable at category level (not 1:1 interchangeable): by clinical indication (endotracheal tube with cuff and Murphy eye, DI 3.5 mm, paediatric/small-size profile) it is comparable to tubes from lines such as Rüsch® and Sheridan® (Teleflex), Shiley™ (Medtronic), Portex™ / SOFT-SEAL™ (ICU Medical) or BOENMED. These brands do not publish a validated equivalence table for code ETAN35C02: outer diameter (OD), total length, geometry and cuff material may differ, so each data sheet must be compared before replacing a specific product.

Comparable by category within the Cahnos catalogue (same 3.5 mm size):

Reference Configuration
ETAN35002 Oral without cuff with Murphy eye (not interchangeable with the cuffed version)
ETPO35C02 Oral preformed with cuff and Murphy eye
ETPN35C02 Nasal preformed with cuff and Murphy eye
840035 Endosid Magill 3.5 mm without balloon
841035 Endosid 3.5 mm with balloon and Murphy eye

There is no manufacturer-validated equivalence table; consult Cahnos’s technical department before use in tenders.

5. Selection tips and variants of interest

  • Selection by patient (usual practice in clinical use, not manufacturer specification): the DI 3.5 mm cuffed size is typically used in paediatric patients of approximately 3–6 years, in small airways or in adults with a narrow canal; the final choice should be based on the service protocol and anaesthetic assessment (age, weight and estimated airway size).
  • Cuff pressure: inflate through the valve with a syringe and maintain a sealing pressure of 20–30 cmH₂O (usual clinical practice range) to minimise tracheal mucosal damage; monitor with a manometer if available.
  • Verification before intubation: check the integrity of the tube, the patency of the Murphy eye, the correct inflation of the cuff and the fixation of the 15 mm connector.
  • Variants of interest: if you need another size, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). For procedures with risk of kinking or external compression, consider the reinforced tubes from the same section; for head and neck surgery, the preformed ranges (ETPO35C02, ETPN35C02).

Additional information

Reference

ETAN35C02

Product type

Oral endotracheal (orotracheal) Magill type with cuff and Murphy eye

Inner diameter

3.5 mm

Material

Medical-grade polyvinyl chloride (PVC), latex-free

Sleeve

Yes, sealing, with pilot balloon and self-sealing valve

Connector

Universal 15 mm (ISO 5356-1)

Marking

Radiopaque line and depth scale

Use

Single-use (sterile, individually packaged)

Sterilisation

Ethylene oxide (EO); verify batch

Presentation

Box of 10 units

Indications

Positive pressure ventilation and anaesthesia administration

Ojo murphy

With Murphy's eye

Reviews

There are no reviews yet.

Be the first to review “Oral Endotracheal Tube (Orotracheal) with Cuff and Murphy Eye – ID 3.5 mm | Medical-Grade PVC, Single-Use, Box of 10 units (Ref. ETAN35C02)”