Description
1. Introduction
The oral endotracheal tube with cuff and Murphy eye of internal diameter 7.5 mm (ref. ETAN75C02) is a single-use airway device designed for orotracheal intubation of adult patients in anaesthesia, intensive care, emergency and resuscitation. Made of medical-grade PVC, latex-free, it combines a low-pressure sealing cuff and the characteristic lateral Murphy eye to provide safe, leak-free positive-pressure ventilation when a ventilation face mask is not viable. It is supplied in a box of 10 units, individually packaged and ready for immediate use in the operating theatre, ICU and emergency services.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is inserted through the mouth under laryngoscopic vision, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The cuff, inflated via the pilot balloon with self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks, also reducing the risk of aspiration. The Murphy eye, a lateral orifice located at the distal end, acts as an alternative gas passage if the tip of the tube becomes obstructed by secretions or by the bevel resting against the tracheal wall. The Magill curve, the atraumatic rounded tip, the radiopaque line and the depth marks facilitate safe placement and radiographic verification. It is a single-use device: after each patient it must be discarded to avoid the risk of cross-infection.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference | ETAN75C02 |
| Type | Oral endotracheal tube (Magill curve) with cuff and Murphy eye |
| Internal diameter (ID) | 7.5 mm (standard adult size) |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Sleeve | Yes, inflatable, with pilot balloon and self-sealing valve |
| Murphy eye | Yes, distal lateral safety opening |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | 15 mm standard, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque line and depth marks |
| Use | Single-use (sterile, individually packaged) |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Presentation | Box of 10 units |
Note: the outer diameter (OD), total length and recommended cuff inflation pressure for this size could not be verified in official public sources from the manufacturer; they remain pending confirmation with the technical department before use in tendering or stock replacement.
Other sizes in the same family (ETAN series, same oral design with cuff and Murphy eye, confirmed in the Cahnos catalogue):
| Inner diameter | SKU (box of 10 units) |
|---|---|
| 2.5 mm | ETAN25C02 |
| 3.0 mm | ETAN30C02 |
| 3.5 mm | ETAN35C02 |
| 4.0 mm | ETAN40C02 |
| 4.5 mm | ETAN45C02 |
| 5.5 mm | ETAN55C02 |
| 6.5 mm | ETAN65C02 |
| 7.0 mm | ETAN70C02 |
| 7.5 mm | ETAN75C02 (this product) |
| 8.0 mm | ETAN80C02 |
| 10.0 mm | ETAN10C02 |
This category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; verify the manufacturer’s declaration of conformity and CE marking on each supplied batch.
4. Equivalences and Cross-References
The SKU ETAN75C02 is Cahnos’s own code and the ETAN family corresponds to the nomenclature of the DEAFLUX line (DEAS S.r.l.) of Magill tracheal tubes with cuff; it should not be confused with other lines from the same manufacturer (preformed ETPO/ETPN, suction lumen ETSL or reinforced ETA) nor with the official part number of any other manufacturer. Therefore, an exact reference equivalence cannot be declared and there is no equivalence table validated by the manufacturer; consult the Cahnos technical department before using this reference in tender specifications or tenders.
Comparable at category level (not 1:1 interchangeable):
- Teleflex / Rüsch® Safety Clear® Plus, standard oral tube with Murphy Eye cuff in 7.5 mm: reference 112082075 appears confirmed in the manufacturer’s online catalogue (Teleflex) for the US market. It is a standard high-volume, low-pressure tube with Murphy eye; it differs in material (Ruschelit®), length and cuff design.
- ICU Medical / Portex™ (formerly Smiths Medical), oral/nasal tracheal tube with SOFT-SEAL™ cuff and Murphy eye in 7.5 mm (320 mm length): reference 100/199/075, consistently confirmed in several independent distribution sources. The cuff system, length and design differ (curved Murphy profile).
- Dahlhausen, Magill line with low-pressure, high-volume balloon: the series is officially documented as 44.000.10.0xx (manufacturer’s catalogue, brochure C73/08/2010), with the 7.5 mm size corresponding to reference 44.000.10.075, distributed by Cahnos. Same indication and general geometry with cuff balloon.
- Teleflex / Rüsch® AGT Oral Cuffed (oral preformed), ref. 111780075 in 7.5 mm: comparable by category, although as a preformed RAE tube with fixed curve it should not be treated as a direct substitute for the oral Magill.
Comparable by category within the Cahnos catalogue (same ID 7.5 mm, other configurations): 841075 (Endosid with cuff and Murphy eye), ETPN75C02 (preformed nasal), ETPO75C02 (preformed oral), ETSL75C02 (subglottic suction lumen) and ETA075C02A2 (reinforced). All are comparable at category level, not interchangeable 1:1. There is no equivalence table validated by the manufacturer for this reference; consult the technical department before use in tendering.
5. Selection tips and variants of interest
Patient selection (usual practice in clinical use, not manufacturer specification): the ID 7.5 mm size is a common size in adult patients, often indicated for women or patients of medium build; as a general guide, tubes of 7.0 to 9.0 mm are usually used depending on age, weight and build, always selecting the largest size compatible with the patient’s anatomy. The final choice should be based on the service protocol and anaesthetic assessment.
Cuff pressure: inflate via the pilot balloon using a syringe and maintain a sealing pressure of around 20–30 cmH₂O (usual range in clinical practice) to minimise tracheal mucosal damage; monitor with a manometer if available in the department. Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen.
Variants of interest in the Cahnos catalogue: if you need another size, the ETAN series covers from 2.5 mm to 10.0 mm (ETAN25C02 to ETAN10C02). For prolonged ventilation with secretion drainage, consider the tube with subglottic suction lumen (ETSL75C02); for procedures requiring kink resistance or frequent repositioning, the reinforced tubes from the intubation section (ETA075C02A2); and for oral, maxillofacial or ENT surgery where keeping the circuit out of the surgical field is important, the preformed tubes (ETPO75C02, ETPN75C02). Contact the Cahnos technical department for samples, volume pricing and hospital supply lead times.