Description
1. Introduction
The Magill Reinforced Endotracheal Tube ENDOSID® from Medline is the reference solution for anaesthesia, resuscitation and critical care when the procedure requires stable airway fixation. Its pre-curved PVC body with spiral reinforcement prevents the tube from bending or collapsing, even during patient movement, frequent repositioning or complex surgical positions, ensuring safe and continuous ventilation throughout the procedure.
Designed for high-turnover hospital consumables, this cuffless tube is available in a wide range of sizes, from 3 to 6.5 mm internal diameter, making it a staple of the paediatric intubation trolley and for reduced airway in the operating theatre, ICU and emergency departments.
2. Technical explanation
The pre-curved Magill design facilitates access to the glottis and adapts better to the patient’s anatomical conditions, being compatible with both oral and nasal routes. The tube wall incorporates a helical spiral reinforcement that provides kink resistance and maintains tracheal lumen patency under external compression, a safety feature for head and neck procedures or those at risk of bending.
The atraumatic tip reduces the risk of injury during insertion, while the graduation along the tube allows clinical verification of intubation depth. As this is a cuffless tube, sealing is achieved by the fit of the size against the tracheal wall, so correct size selection is crucial to minimise leaks and avoid mucosal damage. The proximal end incorporates a universal 15 mm connector compatible with standard circuits and ventilators. It is a single-use device, indicated to prevent the risk of cross-infection.
3. Technical specifications and available references
General characteristics
| Parameter | Specification |
|---|---|
| Tube type | Reinforced (spiral anti-kink reinforcement), Magill-type curvature |
| Sleeve | No (without cuff) |
| Stylet | No |
| Murphy eye | No |
| Syringe | No |
| Access route | Oral and nasal |
| Material | Medical-grade pre-curved PVC |
| Tip | Atraumatic |
| Marking | Depth graduation along the tube |
| Connector | Universal 15 mm |
| Inner diameter | From 3 to 6.5 mm |
| Use | Single-use |
Available references
| Reference | Inner diameter | Units per box | Units per pack |
|---|---|---|---|
| 849645 | 4.5 mm | 50 | 2 |
| 849650 | 5 mm | 50 | 2 |
| 849630A | 3 mm | 50 | 2 |
| 849635A | 3.5 mm | 50 | 2 |
| 849665A | 6.5 mm | 50 | 2 |
| 849640A | 4 mm | 50 | 2 |
| 849650A | 5 mm | 50 | 2 |
| 849645A | 4.5 mm | 50 | 2 |
| 849655A | 5.5 mm | 50 | 2 |
| 849660A | 6 mm | 50 | 2 |
| 849655 | 5.5 mm | 50 | 2 |
- Tube type: Reinforced
- Cuff: No
- Stylet: No
- Murphy eye: No
- Syringe: No
- Single-use: Yes
4. Equivalences and Cross-References
There is no 1:1 equivalence table validated by the manufacturer for this cuffless reference; the following options are offered as a functional category comparison and must be checked data sheet by data sheet (internal and external diameter, length, distal geometry and configuration) before any substitution in tenders or specifications.
| Manufacturer / Line | Indicative reference | Observations |
|---|---|---|
| Medline (ENDOSID®) – same family with cuff | Series 8495xx (849535A, 849540A, 849550A, 849560A, 849565A…) | Same spiral reinforcement and Magill curvature, but with HVLP cuff and syringe; not interchangeable 1:1 with the cuffless version |
| Teleflex (Rüsch® / RüschFlex) | Reinforced line with and without cuff | Comparable by category; verify configuration and size |
| P. J. Dahlhausen (Woodbridge) | Reinforced series 44.000.20.0XX | Comparable by category; check technical data sheet |
| Medtronic (Shiley™ / Mallinckrodt™) | Reinforced series | Comparable by category; check technical data sheet and IFU |
Consult the technical department of Cahnos before using these references as equivalence in tenders or specifications.
5. Selection tips and variants of interest
Select the size according to the patient’s anatomy and the service protocol: this cuffless range from 3 to 6.5 mm internal diameter is mainly intended for paediatric or reduced-calibre airways, always choosing the largest size compatible with the patient’s anatomy. As it has no balloon, pay special attention to the fit of the tube in the trachea to minimise leaks and the risk of aspiration.
Before insertion, check the integrity of the tube, the patency of the lumen and the correct attachment of the 15 mm connector. If the procedure requires an airtight seal or prolonged ventilation, consider the variant of the same ENDOSID® family with a high-volume, low-pressure cuff available in the Cahnos catalogue. Single-use device: do not re-sterilise or reuse. Product available on quotation; contact your technical-commercial representative at Cahnos for volume pricing, samples and hospital delivery times.