Description
1. Commercial Introduction
The endotracheal tube with a 4.5 mm Ø cuff is the reference solution for safe airway management in paediatric patients, adolescents or adults with a reduced calibre during anaesthesia, intensive care, emergencies and resuscitation. Its manufacture in thermosensitive PVC with resistant walls ensures adequate and stable ventilation for all patients, while the low-profile cuff provides an effective seal with the lowest possible pressure on the tracheal mucosa.
It is presented in a box of 100 sterile single-use units, designed for continuous supply to the service. A variety of calibres in the range allows a safe airway to be maintained throughout the surgical procedure.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is introduced orally under laryngoscopic vision, passes through the glottis and is placed in the trachea, where it conducts gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The cuff, inflated via the pilot balloon with a self-sealing valve, seals the tracheal lumen: it allows positive-pressure ventilation without significant leaks, prevents aspiration of secretions and stabilises the device during mechanical ventilation.
- Cylindrical high-volume, low-pressure cuffs: effective sealing minimising pressure damage to the tracheal mucosa.
- Sensitive pilot balloons: controlled inflation and quick seal check.
- Finely heat-sealed cuffs: greater strength and integrity.
- Rounded ends (atraumatic tip): smooth insertion that reduces trauma.
- Crack-resistant radiopaque lines: reliable radiographic verification of position.
- Smooth Murphy eyes: distal lateral safety orifice that ensures flow continuity if the main lumen becomes obstructed.
- Compression-resistant thermosensitive tubes: the material adapts to body temperature while resisting kinking.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 57653 |
| Diameter (Ø) | 4.5 mm |
| Tube length | 22.5 cm |
| Material | Thermosensitive PVC with resistant walls |
| Sleeve | High volume, low pressure, cylindrical shape |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920052 |
| Sales unit | Box of 100 units |
| Minimum order | Box of 100 units |
| Sterility | Sterile (ethylene oxide) |
| Use | Single-use, disposable |
Design features
| Sleeve | High volume, low pressure, cylindrical shape |
|---|---|
| Pilot balloon | Sensitive, with self-sealing valve |
| Heat-sealed | Finely heat-sealed cuff |
| Tip | Rounded, atraumatic (bull-nose type) |
| Radiopaque line | Crack-resistant |
| Murphy eye | Present, smooth |
| Resistance | Thermosensitive and kink-resistant |
Manufactured in accordance with the standards applicable to airway devices; verify the declaration of conformity and the CE/MDR marking on each supplied batch. Sterile single-use device: do not re-sterilise or reuse.
4. Equivalences and Cross-References
Reference 57653 (endotracheal tube with cuff, Ø 4.5 mm, box of 100) does not have a table of equivalences validated by the manufacturer against other brands. At category level, in the Cahnos catalogue there are comparable configurations of oral tubes with cuff and Murphy eye in 4.5 mm calibre that must be verified sheet by sheet before their substitution in tenders or bids:
| Reference | Description | Key difference |
|---|---|---|
| ETAN45C02 | Oral tube with cuff and Murphy eye, ID 4.5 mm | Box of 10 units |
| 841045 | Tube with low-pressure cuff and Murphy eye, ID 4.5 mm | Format and inflation system |
| ETAN45002 | Oral tube without cuff, ID 4.5 mm | Without cuff |
| ETA045C02A2 | Reinforced oral tube with cuff, ID 4.5 mm | Helical reinforcement |
| ETAM45C02A1 | Reinforced oral tube with cuff and guide, ID 4.5 mm | Includes guide |
| PB-212045U | ISSO PRO-BREATHE, ID 4.5 mm | Comparable by category |
| 44.000.10.045 / 44.000.11.045 | P. J. Dahlhausen, Magill with balloon, 4.5 mm | Pending confirmation |
There is no validated direct equivalence for this reference; consult the technical-commercial department of Cahnos before using this product as a direct substitute for another brand.
5. Selection tips and variants of interest
The Ø 4.5 mm calibre is intended for older paediatric patients and adults with a reduced airway calibre; the final choice must be based on the age, weight and anaesthetic assessment of each patient, always selecting the largest size compatible with their anatomy according to the service protocol.
Before intubation, check the integrity of the cuff, pilot balloon and valve, as well as the patency of the lumen and the sterility expiry date. After placement, inflate the cuff via the pilot balloon maintaining a sealing pressure within the usual clinical range (ideally 20-30 cmH₂O, verify the centre’s protocol) to minimise the risk of tracheal mucosal injury, and confirm the position using the radiopaque line and depth marks. The device is single-use and must be discarded after each procedure as healthcare waste in accordance with current local regulations.
To complete the intubation trolley stock, consult the other calibres in the range and the reinforced, preformed or subglottic suction lumen variants available at Cahnos.




Reviews
There are no reviews yet.