Endotracheal tube with cuff Ø 7.0 mm (Ref. 57658)
1. Introduction
The 7.0 mm endotracheal tube with cuff (ref. 57658) is a single-use airway device manufactured from medical-grade PVC, designed to ensure rapid, safe and reproducible orotracheal intubation in anaesthesia, emergency and intensive care units. Its resistant walls guarantee adequate ventilation for all types of patients, while the availability of different sizes allows a secure airway to be maintained throughout the surgical procedure or the period of ventilatory support. It is presented in a box of 100 units, individually packaged and sterile, ready for immediate use in the operating theatre, ICU and pre-hospital care.
2. Technical explanation of the device and procedure
In orotracheal intubation, the tube is introduced through the mouth, passes through the glottis and sits in the trachea, where it conducts gases from the ventilator or anaesthesia circuit to the lungs. The cylindrical high-volume, low-pressure cuff, inflated via the pilot balloon with a self-sealing valve, seals the trachea and allows positive-pressure ventilation without significant leaks, minimising the pressure exerted on the tracheal mucosa. The Murphy eye, a distal lateral opening, ensures an alternative gas passage if the tip of the tube becomes obstructed by secretions or by the bevel resting against the tracheal wall. The radiopaque line facilitates radiographic confirmation of correct placement, and the thermosensitive material reduces the risk of kinking. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
| Internal diameter (ID) | 7.0 mm |
|---|---|
| Tube length | 30.5 cm |
| Material | Medical-grade polyvinyl chloride (PVC), with resistant walls and thermosensitive tube |
| Cuff type | High volume / low pressure, cylindrical (barrel-shaped) |
| Pilot balloon | Sensitive, with self-sealing valve |
| Murphy eye | Yes, smooth |
| Tip | Rounded (bull-nose type) |
| Marking | Crack-resistant radiopaque line |
| Sterility | Sterile, single-use |
| Presentation | Box of 100 units (minimum order: box of 100) |
Product data
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 57658 |
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920106 |
Note: this type of tracheal tube is manufactured in accordance with the requirements of standard ISO 5361 (tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices; check the manufacturer’s declaration of conformity and CE marking on each supplied batch.
4. Equivalences and Cross-References
Reference 57658 is the manufacturer’s code for this standard 7.0 mm PVC endotracheal tube with cuff; the store SKU is GM57658. To date, there is no equivalence table validated by the manufacturer against other brands, so no exact or interchangeable 1:1 reference equivalence can be declared. At category level, it is comparable to oral endotracheal tubes with high-volume, low-pressure cuffs, Murphy eye and radiopaque line from generic import lines (BOENMED, Greetmed, Pinmed, etc.) and from the main airway manufacturers (e.g. Magill lines with cuff from Rüsch/Teleflex or AirLife), which differ in material, cuff geometry, length and inflation pressure. Consult our technical department before using this reference as an equivalence in tenders or bids.
5. Selection tips and variants of interest
Selection by patient: the 7.0 mm size is commonly used in adult patients of small or medium build and in adult women; as a general guide, tubes with an ID of 7.0–8.5 mm are usually used in women and 8.0–9.0 mm in men. The final choice must always be based on the department’s protocol and the patient’s anaesthetic assessment, selecting the largest size compatible with their anatomy. Cuff pressure: inflate via the pilot balloon with a syringe and maintain a sealing pressure of 20–30 cmH2O (usual clinical practice range) to minimise damage to the tracheal mucosa; monitor with a manometer if the department has one. Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen. If you need other sizes or configurations (uncuffed tubes, Murphy eye, preformed nasal or oral tubes, reinforced tubes or emergency kits with stylet and syringe), consult the Cahnos intubation range: our technical department will advise you on the most suitable variant for your use and will provide you with volume conditions and hospital supply lead times.