Description
1. Commercial Introduction
The reinforced oral endotracheal tube, uncuffed, with Murphy eye, 4.5 mm internal diameter (Ref. ETA045002A2) is the airway solution that anaesthesia, paediatric, emergency and intensive care departments need to ensure positive-pressure ventilation and administration of anaesthesia when a ventilation face mask cannot be used.
Made from medical-grade polyvinyl chloride (PVC), transparent and latex-free, it combines the strength of the anti-kink helical reinforcement with the safety of the Murphy eye, providing a patent and stable airway during critical procedures. It is supplied in a box of 10 individually packaged units, designed for the intubation trolley and high-turnover hospital consumables, ensuring a uniform and reliable standard in every procedure.
2. Technical explanation of the equipment and procedure
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision, passes through the glottis and sits in the trachea below the vocal cords, conducting gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The helical reinforcement integrated into the PVC wall prevents tube collapse under external compression, biting or kinking, making it especially suitable for head and neck surgery, ENT, maxillofacial procedures, prone positioning and complex surgical positions, as well as for paediatric patients who move their head during ventilation.
Being an uncuffed tube, sealing is achieved by the anatomical fit of the calibre against the tracheal wall, a common practice in paediatric patients and reduced-calibre airways, as it minimises pressure on the mucosa. The Murphy eye, a lateral opening at the distal end, acts as an alternative ventilation route: if the main lumen becomes obstructed by secretions or by the bevel resting against the tracheal wall, airflow continues through this opening, ensuring continuity of ventilation. The Magill curve, rounded atraumatic tip, radiopaque contrast line and depth marks facilitate safe placement and radiographic verification. It is a single-use device: it must be discarded after each patient to avoid any risk of cross-infection.
3. Technical Specifications
The specifications listed below correspond to the technical data published for this reference in the Cahnos catalogue:
| Parameter | Specification |
| Reference (SKU) | ETA045002A2 (distributor’s own code Cahnos; reinforced uncuffed ETA series) |
| Type | Oral endotracheal tube (orotracheal), Magill-type curvature, reinforced |
| Material | Medical-grade polyvinyl chloride (PVC), transparent, latex-free |
| Internal diameter (ID) | 4.5 mm (paediatric calibre / reduced-calibre airway) |
| Configuration | Reinforced, uncuffed (sealed by anatomical fit of the calibre) |
| Reinforcement | Anti-kink helical spiral integrated into the tube wall |
| Key feature | Murphy eye (distal lateral safety opening) for visualisation, positioning and continuity of flow |
| Sleeve | Uncuffed (no cuff inflation) |
| Tip | Atraumatic, rounded and gently bevelled |
| Connector | Universal 15 mm, compatible with ISO circuits (ISO 5356-1) |
| Marking | Radiopaque contrast line and depth graduation |
| Sterilisation | Ethylene oxide (EO), sterile, individually packaged |
| Use | Single-use, non-reusable |
| Indication | Positive pressure ventilation and anaesthesia administration when face mask is not viable |
| Indicative population | Paediatric (infants and young children) / reduced-calibre airway |
| Presentation | Box of 10 units |
| Regulatory standard | ISO 5361 (tracheal tubes and connectors); connector according to ISO 5356-1; sterilisation according to EN ISO 11135-1; verify CE/MDR marking of each batch |
Range of calibres confirmed in the Cahnos catalogue (ETA…002A2 series, reinforced oral uncuffed tubes with Murphy eye, same configuration and presentation in boxes of 10 units):
| Reference | Internal diameter (ID) |
| ETA030002A2 | 3.0 mm |
| ETA035002A2 | 3.5 mm |
| ETA040002A2 | 4.0 mm |
| ETA045002A2 (this product) | 4.5 mm |
| ETA050002A2 | 5.0 mm |
| ETA055002A2 | 5.5 mm |
| ETA060002A2 | 6.0 mm |
| ETA065002A2 | 6.5 mm |
| ETA070002A2 | 7.0 mm |
| ETA075002A2 | 7.5 mm |
| ETA080002A2 | 8.0 mm |
| ETA085002A2 | 8.5 mm |
| ETA090002A2 | 9.0 mm |
| ETA095002A2 | 9.5 mm |
| ETA010002A2 | 10.0 mm |
Note: this category of tracheal tubes is manufactured in accordance with the requirements of standard ISO 5361 (respiratory and anaesthesia equipment: tracheal tubes and connectors) and the biocompatibility standards applicable to airway devices. Verify the declaration of conformity, CE/MDR marking and the manufacturer’s classification on each supplied batch before use in procedures.
4. Equivalences and Cross-References
The reference ETA045002A2 is a code specific to the Cahnos catalogue (ETA series, technical nomenclature of the DEAFLUX line from DEAS S.r.l., Italy) and should not be confused with the official reference number of any particular manufacturer. To date, there is no manufacturer-validated equivalence table for this exact configuration (oral, reinforced, uncuffed, with Murphy eye, ID 4.5 mm), so the following options are classified as comparable at category level (same general clinical indication, not interchangeable 1:1), with their verification status indicated:
| Manufacturer / Line | Reference (ID 4.5 mm) | Degree of correspondence |
| Intersurgical (InTube™) | 8050045 | Comparable by category; code confirmed in Intersurgical’s official catalogue. No helical reinforcement; same calibre, uncuffed and with Murphy eye |
| P. J. Dahlhausen & Co. GmbH (Magill series) | 44.000.11.045 | Comparable by category; code confirmed in the manufacturer’s official documentation. Magill tube, uncuffed and without guide, with Murphy eye, but without spiral reinforcement |
| ENDOSID® (Asid Bonz / Well Lead, via Medline EU) | 843045 | Comparable by category; code confirmed in Medline EU’s official catalogue. Magill tube, uncuffed with Murphy eye, without spiral reinforcement |
| Teleflex / Rüsch® (Safety Clear™ Murphy Eye Uncuffed) | 506545 | Pending confirmation against the manufacturer’s official data sheet; found at authorised distributors. Verify reinforcement system, outer diameter and packaging |
| Flexicare® (VentiSeal) | 038-966-045U / 038-964-045U | Pending documentary confirmation; data from authorised distributor. Same calibre and uncuffed configuration with Murphy eye |
Comparable at category level within the Cahnos catalogue in the same ID 4.5 mm calibre (not interchangeable 1:1):
| Reference | Description | Key difference |
| ETAN45002 | Oral uncuffed tube with Murphy eye, ID 4.5 mm | Without helical reinforcement |
| ETA045C02A2 | Reinforced oral tube with cuff and Murphy eye, ID 4.5 mm | Incorporates a cuff |
| ETAM45C02A1 | Reinforced oral tube with cuff, insertion guide and Murphy eye, ID 4.5 mm | Adds included insertion stylet |
| ETAN45C02 | Oral tube with cuff and Murphy eye, ID 4.5 mm | Without helical reinforcement and with cuff |
At market level, reinforced oral endotracheal tubes without cuff coincide in functional category with families such as Rüsch® / Sheridan® (Teleflex), Shiley™ (Medtronic) or Portex® (ICU Medical), but it is essential to verify in each technical data sheet the external diameter, total length, material, presence of Murphy eye and type of reinforcement before replacing the device in a care protocol. There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using this reference as an equivalence in tenders or bids or as a direct replacement for stock from other brands.
5. Selection tips and variants of interest
Size selection: the 4.5 mm ID is intended for paediatric patients (infants and young children) or those with a reduced airway calibre. As a general clinical practice guideline (not a manufacturer specification), in the paediatric range tubes from 3.5 to 5.0 mm are used according to age, weight and anaesthetic assessment; always select the largest size compatible with the patient’s anatomy and the centre’s protocol. As it lacks a cuff, the choice of size determines the seal: an adequate calibre minimises leaks and avoids mucosal damage.
Pre-intubation verification: check the integrity of the tube, the patency of the Murphy eye and the correct attachment of the 15 mm connector to the circuit, as well as the expiry date of sterility. Verify the position after placement using the radiopaque line and depth marks. Single-use product: do not re-sterilise or reuse and follow the centre’s healthcare waste management protocols.
Variants of interest in the Cahnos catalogue: if the procedure requires an airtight seal or prolonged ventilation, consider the reinforced tube with cuff of the same calibre (Ref. ETA045C02A2); if insertion assistance is required, Ref. ETAM45C02A1; and if anti-kink reinforcement is not needed, the standard variant without cuff of the same calibre (Ref. ETAN45002). Complete the intubation trolley stock with the adjacent calibres of the range (ETA040002A2 and ETA055002A2) and consult the technical-commercial department of Cahnos for samples, volume conditions and the approval of references for your tender.




Reviews