Description
1. Secure airway for intubation and mechanical ventilation
The endotracheal tube with a 4.0 mm cuff is the airway solution that anaesthesia, intensive care, emergency and resuscitation services need to ensure positive-pressure ventilation and anaesthesia delivery when face mask use is not viable. Manufactured from medical-grade polyvinyl chloride (PVC) and supplied sterile in a box of 100 units, it combines resistant walls with a carefully designed structure to protect the tracheal mucosa and maintain airway patency during short and long procedures.
2. Technical explanation of the device
In orotracheal intubation, the tube is inserted orally under laryngoscopic vision until its distal end is placed in the trachea, where it conducts gases from the ventilator, anaesthesia circuit or resuscitation bag to the lungs. The cuff, inflated via the pilot balloon, seals the tracheal lumen against the tube: it prevents gas leaks, reduces the risk of aspiration of secretions and stabilises the device during mechanical ventilation. The Murphy eye, a lateral opening at the distal end, acts as an alternative ventilation route: if the tip becomes obstructed by secretions or rests against the tracheal wall, respiratory flow continues through this opening, so occlusion is never total.
- Barrel-shaped, high-volume, low-pressure cuffs: effective sealing with lower pressure on the tracheal mucosa.
- Sensitive pilot balloons, facilitating inflation checks and cuff pressure control.
- Finely heat-sealed cuffs, ensuring the airtightness of the cuff seal.
- Round, atraumatic bull-nose tips, minimising the risk of injury during insertion.
- Crack-resistant radiopaque lines for radiographic verification of tube position.
- Smooth Murphy eyes, ensuring backup ventilation without rough surfaces.
- Heat-sensitive, kink-resistant tubes that maintain patency under flexion and compression.
3. Technical specifications and product data
Main characteristics
| Diameter | Ø 4.0 mm (internal lumen) |
|---|---|
| Tube length | 20.5 cm |
| Material | Medical-grade polyvinyl chloride (PVC) |
| Sleeve | High volume and low pressure, barrel-shaped |
| Pilot balloon | Yes, sensitive |
| Murphy eye | Yes, smooth |
| Radiopaque line | Yes, crack-resistant |
| Sterilisation | Sterile (individual packaging) |
| Use | Single-use, disposable |
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | Box of 100 units |
| Device type | Medical device |
| Device class | II A |
| CND | R010399 |
| EAN | 6972091920045 |
Manufactured with resistant tube walls to ensure adequate ventilation in all types of patients; the range of available sizes allows a secure airway to be maintained throughout the surgical procedure. Manufacturer reference: 57652 (SKU Cahnos GM57652).
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this reference, so the following options should be considered comparable at category level (not interchangeable 1:1 without prior technical verification).
| Reference | Description | Degree of correspondence |
|---|---|---|
| 841040 (ENDOSID, catalogue Cahnos) | Endotracheal tube with low-pressure cuff and Murphy eye, ID 4.0 mm | Confirmed comparable in own catalogue: same configuration and calibre; differ in manufacturer of origin, inflation system and supply format. |
| ETAN40C02 (Cahnos) | Oral endotracheal tube with cuff and Murphy eye, ID 4.0 mm, medical PVC | Comparable by category in own catalogue; verify inflation system and outer diameter. |
| PB-212040U (ISSO PRO-BREATHE) | Tracheal tube with cuff, ID 4.0 mm | Comparable by category; pending verification of official data sheet |
| 44.000.10.040 / 44.000.11.040 (P. J. Dahlhausen) | Magill tracheal tubes with cuff, ID 4.0 mm | Comparable by category; exact code confirmation pending |
Consult the technical department of Cahnos before using this reference as an equivalence in specifications, tenders or direct substitution of other brands.
5. Selection tips and variants of interest
The 4.0 mm calibre is intended for paediatric patients and reduced-calibre airways (general clinical practice guidance of 3.5 to 5.0 mm in this range); the final choice should be based on the age, weight and individual anaesthetic assessment of each patient, as well as on the service protocol.
Before intubation, check the integrity of the cuff, the pilot balloon and the patency of the lumen; inflate with a syringe and maintain a sealing pressure in the usual clinical range (20–30 cmH₂O) to minimise the risk of pressure injury to the tracheal mucosa, monitoring with a manometer if the service has one available.
If you need other sizes, the family of cuffed tubes allows you to complete the intubation trolley stock from paediatric to adult sizes. Contact the technical-commercial department of Cahnos for samples, volume conditions and hospital supply lead times.




Reviews
There are no reviews yet.