We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

HANDLIN Uterine Injector Manipulator | Graduated Dual-Lumen Catheter 4-10 cm, 10 cc PVC Balloon and Luer Lock Connector for Hysterosalpingography and Gynaecological Laparoscopy (Box of 10 Units) – Ref. 720199

429,60 €

The HANDLIN uterine injector manipulator (ref. 720199) combines firm uterine manipulation with controlled injection of contrast media in a single device. It incorporates an internal dual-lumen catheter with graduation from 4 to 10 cm, 10 cc PVC balloon (Ø 20 mm) that minimises perforations and prevents contrast reflux, rigid handle with locking system, one-way inflation valve with indicator pilot and Luer Lock connector. Indicated for diagnostic and surgical laparoscopy, hysterosalpingography, sonohysterography and fertility studies. Presentation in a box of 10 units.

International shipping. Import duties and taxes are payable by the recipient.

Reference
720199

Description

1. Uterine manipulation and contrast injection in a single instrument

The HANDLIN uterine injector manipulator (ref. 720199) is the solution designed for gynaecological procedures in which the specialist needs, at the same time, to orient and stabilise the uterus and to administer the contrast medium safely and in a controlled manner. Its dual-function design avoids having to handle two separate devices, reduces examination times and provides excellent manoeuvrability both in the operating theatre (diagnostic and surgical laparoscopy) and in the diagnostic imaging department and assisted reproduction units.

Manufactured with a curved body that facilitates insertion, this disposable instrument is supplied in a box of 10 units, ideal for hospital supplies, gynaecology operating theatres and radiology departments with high material turnover.

2. Technical explanation of the equipment and procedure

The HANDLIN is designed for procedures in which uterine manipulation and/or injection of radiopaque contrast media (for example, in hysterosalpingography) or physiological saline solution (sonohysterography) is required. Its internal dual-lumen catheter allows the balloon inflation channel to be separated from the injection channel: one lumen is used to inflate the distal balloon and the other for administering the contrast medium through the Luer Lock connector.

The graduation from 4 to 10 cm (1 cm resolution)* printed on the catheter allows the professional to assess the correct insertion depth and adjust it to each patient’s anatomy, avoiding contact with the uterine fundus. The 10 cc PVC balloon, 20 mm in diameter, acts as a fixation and sealing element at the internal cervical os: when inflated, it minimises the risk of accidental perforation and blocks contrast reflux into the vagina, favouring uterine distension and correct visualisation of the cavity and the fallopian tubes. The one-way inflation valve, connected to a balloon pilot, shows the real status of the internal balloon at all times, and the rigid handle with locking system ensures firm manipulation without accidental movements throughout the procedure.

3. Technical Specifications

Parameter Specification
Device type Uterine manipulator-injector
Reference 720199 (own code Cahnos)
Presentation Box of 10 units
Catheter Internal double-lumen with 4 to 10 cm graduation (1 cm resolution)*
Handle Rigid, for firm and safe manipulation of the uterus
Locking system Simple, prevents accidental movements during the procedure
Cuff 10 cc PVC, Ø 20 mm, placed at the catheter tip
Inflation valve Unidirectional, connected to indicator balloon pilot
Connection Luer lock connector for contrast media injection
Shape Curved, for easy insertion

*Indicative measurement scale, to guide insertion depth.

4. Equivalences and Cross-References

There is no official equivalence table validated by the manufacturer for this reference: it is a distributor-specific code within the uterine manipulation and injection range. The references indicated below belong to the same functional category (intrauterine contrast injection for hysterosalpingography/sonohysterography), but are not interchangeable 1:1: the HANDLIN differs through its dual manipulator function, its 10 cc balloon and its graduated dual-lumen catheter.

Reference / Family Equivalence level Main technical differences
RIGIDINJECTOR (refs. 720225, 720239, 720251) Comparable by category (hysterosalpingography) Rigid 5-7 Fr catheter with 2.5 cc oval thermoplastic rubber balloon; without manipulator handle or 4-10 cm graduation
SOFTINJECTOR (refs. 720226, 720240, 720250) Comparable by category (hysterosalpingography) Flexible 5-7 Fr catheter with 2.5 cc balloon; without firm manipulation function
Injector Plus (ref. 730226) Comparable by category (hysterosalpingography/sonohysterography) Semi-rigid 6 Fr double-lumen catheter, 2.5 cc balloon, steel stylet and syringe included
MININJECTOR (refs. 770314, 880314) Comparable by category (sonohysterography) Smaller-calibre 5 Fr catheter, oriented to ultrasound imaging, without balloon adapted for laparoscopic manipulation
PM-CARE® 2V-CUP (ref. PS3460845) Comparable by category (hysterography) Cervical sealing by vacuum cup instead of balloon; rigid catheter 8.5 Fr × 400 mm

At market level, cervical sealing balloon devices for hysterosalpingography from manufacturers such as CooperSurgical, Argon Medical, Bexen Medical or Prince Medical occupy the same functional segment; however, the exact equivalences of calibre, length and fixation system must be verified against each brand’s technical data sheets. Consult the technical department before using this reference in a tender or product substitution.

5. Selection tips and variants of interest

For laparoscopic surgery and fertility studies: the HANDLIN is the recommended option when the uterus needs to be actively manipulated and contrast injected in the same procedure, thanks to its rigid handle, locking system and 10 cc balloon.

For conventional hysterosalpingography (HSG): if the priority is a lightweight, smaller-calibre system with fixation balloon, consider the RIGIDINJECTOR (rigid catheter) or SOFTINJECTOR (flexible catheter) injectors in 5, 6 or 7 Fr.

For ultrasound-only sonohysterography: the 5 Fr MININJECTOR devices offer a finer profile and less distension, indicated for studies with physiological saline.

For alternative cervical sealing: if your department prefers a vacuum cup instead of a balloon, the PM-CARE® 2V-CUP family (cups of Ø 23, 28 and 35 mm) is a functional alternative from the same diagnostic range.

In all cases, confirm the contrast medium to be used (water-soluble iodinated contrast for HSG, methylene blue or physiological saline according to protocol) and verify the compatibility of the Luer Lock connector with the injection line of your equipment. For hospitalisation orders, annual contracts or individual sterile-packaging requirements, please consult volume conditions with our commercial team.

Additional information

Reference

720199

Product type

Uterine manipulator-injector

Presentation

Box of 10 units

Catheter

Double-lumen with 4 to 10 cm graduation (1 cm resolution)

Handle

Rigid with locking system

Balloon

10 cc PVC, 20 mm diameter

Inflation valve

Unidirectional with indicator balloon pilot

Connection

Luer lock for contrast media injection

Shape

Curved for easy insertion

Application

Diagnostic and surgical laparoscopy, hysterosalpingography, sonohysterography, fertility studies

Compatible media

Radiopaque contrast, methylene blue, saline solution

Reviews

There are no reviews yet.

Be the first to review “HANDLIN Uterine Injector Manipulator | Graduated Dual-Lumen Catheter 4-10 cm, 10 cc PVC Balloon and Luer Lock Connector for Hysterosalpingography and Gynaecological Laparoscopy (Box of 10 Units) – Ref. 720199”

Your email address will not be published. Required fields are marked *