Description
1. Uterine manipulation and contrast injection in a single instrument
The HANDLIN uterine injector manipulator (ref. 720199) is the solution designed for gynaecological procedures in which the specialist needs, at the same time, to orient and stabilise the uterus and to administer the contrast medium safely and in a controlled manner. Its dual-function design avoids having to handle two separate devices, reduces examination times and provides excellent manoeuvrability both in the operating theatre (diagnostic and surgical laparoscopy) and in the diagnostic imaging department and assisted reproduction units.
Manufactured with a curved body that facilitates insertion, this disposable instrument is supplied in a box of 10 units, ideal for hospital supplies, gynaecology operating theatres and radiology departments with high material turnover.
2. Technical explanation of the equipment and procedure
The HANDLIN is designed for procedures in which uterine manipulation and/or injection of radiopaque contrast media (for example, in hysterosalpingography) or physiological saline solution (sonohysterography) is required. Its internal dual-lumen catheter allows the balloon inflation channel to be separated from the injection channel: one lumen is used to inflate the distal balloon and the other for administering the contrast medium through the Luer Lock connector.
The graduation from 4 to 10 cm (1 cm resolution)* printed on the catheter allows the professional to assess the correct insertion depth and adjust it to each patient’s anatomy, avoiding contact with the uterine fundus. The 10 cc PVC balloon, 20 mm in diameter, acts as a fixation and sealing element at the internal cervical os: when inflated, it minimises the risk of accidental perforation and blocks contrast reflux into the vagina, favouring uterine distension and correct visualisation of the cavity and the fallopian tubes. The one-way inflation valve, connected to a balloon pilot, shows the real status of the internal balloon at all times, and the rigid handle with locking system ensures firm manipulation without accidental movements throughout the procedure.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Device type | Uterine manipulator-injector |
| Reference | 720199 (own code Cahnos) |
| Presentation | Box of 10 units |
| Catheter | Internal double-lumen with 4 to 10 cm graduation (1 cm resolution)* |
| Handle | Rigid, for firm and safe manipulation of the uterus |
| Locking system | Simple, prevents accidental movements during the procedure |
| Cuff | 10 cc PVC, Ø 20 mm, placed at the catheter tip |
| Inflation valve | Unidirectional, connected to indicator balloon pilot |
| Connection | Luer lock connector for contrast media injection |
| Shape | Curved, for easy insertion |
*Indicative measurement scale, to guide insertion depth.
4. Equivalences and Cross-References
There is no official equivalence table validated by the manufacturer for this reference: it is a distributor-specific code within the uterine manipulation and injection range. The references indicated below belong to the same functional category (intrauterine contrast injection for hysterosalpingography/sonohysterography), but are not interchangeable 1:1: the HANDLIN differs through its dual manipulator function, its 10 cc balloon and its graduated dual-lumen catheter.
| Reference / Family | Equivalence level | Main technical differences |
|---|---|---|
| RIGIDINJECTOR (refs. 720225, 720239, 720251) | Comparable by category (hysterosalpingography) | Rigid 5-7 Fr catheter with 2.5 cc oval thermoplastic rubber balloon; without manipulator handle or 4-10 cm graduation |
| SOFTINJECTOR (refs. 720226, 720240, 720250) | Comparable by category (hysterosalpingography) | Flexible 5-7 Fr catheter with 2.5 cc balloon; without firm manipulation function |
| Injector Plus (ref. 730226) | Comparable by category (hysterosalpingography/sonohysterography) | Semi-rigid 6 Fr double-lumen catheter, 2.5 cc balloon, steel stylet and syringe included |
| MININJECTOR (refs. 770314, 880314) | Comparable by category (sonohysterography) | Smaller-calibre 5 Fr catheter, oriented to ultrasound imaging, without balloon adapted for laparoscopic manipulation |
| PM-CARE® 2V-CUP (ref. PS3460845) | Comparable by category (hysterography) | Cervical sealing by vacuum cup instead of balloon; rigid catheter 8.5 Fr × 400 mm |
At market level, cervical sealing balloon devices for hysterosalpingography from manufacturers such as CooperSurgical, Argon Medical, Bexen Medical or Prince Medical occupy the same functional segment; however, the exact equivalences of calibre, length and fixation system must be verified against each brand’s technical data sheets. Consult the technical department before using this reference in a tender or product substitution.
5. Selection tips and variants of interest
For laparoscopic surgery and fertility studies: the HANDLIN is the recommended option when the uterus needs to be actively manipulated and contrast injected in the same procedure, thanks to its rigid handle, locking system and 10 cc balloon.
For conventional hysterosalpingography (HSG): if the priority is a lightweight, smaller-calibre system with fixation balloon, consider the RIGIDINJECTOR (rigid catheter) or SOFTINJECTOR (flexible catheter) injectors in 5, 6 or 7 Fr.
For ultrasound-only sonohysterography: the 5 Fr MININJECTOR devices offer a finer profile and less distension, indicated for studies with physiological saline.
For alternative cervical sealing: if your department prefers a vacuum cup instead of a balloon, the PM-CARE® 2V-CUP family (cups of Ø 23, 28 and 35 mm) is a functional alternative from the same diagnostic range.
In all cases, confirm the contrast medium to be used (water-soluble iodinated contrast for HSG, methylene blue or physiological saline according to protocol) and verify the compatibility of the Luer Lock connector with the injection line of your equipment. For hospitalisation orders, annual contracts or individual sterile-packaging requirements, please consult volume conditions with our commercial team.





Reviews