Description
The mini catheter PM-LIFE® IU CH5 (reference PS1260500) is the disposable solution of choice for assisted reproduction clinics and gynaecology units performing intrauterine inseminations (IUI). Its reduced CH5 calibre of 1.65 mm allows comfortable, atraumatic passage through the cervical canal, making it the preferred option for narrow cervical canals or sensitive patients. Each unit is supplied sterile, individually packaged, and is latex-free to maximise patient safety.
Technical explanation of the procedure
Intrauterine insemination involves depositing a washed and capacitated sperm sample directly into the uterine cavity, increasing sperm concentration at the appropriate site at the time of ovulation. This catheter connects to a syringe or transfer system via its connector and advances through the cervical canal into the uterus. The centimetre graduations printed along the body allow the clinician to control placement depth with total precision, while the 1 mm holes located at the 45 mm distal end facilitate gentle, homogeneous release of the seminal sample. As a single-use, sterile, Class Is device, it completely eliminates the risk of cross-contamination between procedures and guarantees the optimal biosafety conditions required in medically assisted reproduction (MAR) techniques. This model, without introducer or stylet, offers maximum simplicity and economy for standard procedures.
Technical specifications
| Characteristic | Value |
|---|---|
| Type | Intrauterine insemination catheter (IU) |
| Brand / Range | PM-LIFE® IU |
| Reference | PS1260500 |
| Gauge | CH5 |
| Diameter | 1.65 mm |
| Usable volume | 1.1 ml |
| Length | 175 mm |
| Hole diameter | 1 mm |
| Distal end length | 45 mm |
| Centimetric graduations | Yes |
| Introducer (insertor) | No |
| Mandrel | No |
| Single-use | Yes |
| Product class | Is |
| Sterile | Yes |
| Sterilisation method | Gamma radiation |
| Contains latex | No |
| Shelf life | 5 years |
| Certification | CE |
| Launch date | 2002 |
| Presentation | Box of 25 units in individual sterile packaging |
| Storage | In its original box, in a cool, dry place |
Equivalences and cross-references
This mini CH5 catheter without introducer or stylet (PS1260500) belongs to the PM-LIFE® IU intrauterine insemination catheter range, which complement each other according to calibre and guidance system:
- PS1270500 – Mini CH5 catheter with introducer (Ø 1.65 mm, volume 1.1 ml): adds a stable guide for anatomies with angulations.
- PS4130500 – Mini CH5 catheter with stylet (Ø 1.65 mm, volume 1.1 ml): allows pre-forming of the distal end.
- PS4160500 – CH5 catheter with introducer and stylet (Ø 1.65 mm, volume 1.1 ml): combines both guidance systems.
- PS1260600 / PS1270600 / PS4130600 / PS4160600 – CH6 range (Ø 2 mm, volume 1.6 ml) for larger sample volumes or smoother passage.
Due to its functional characteristics (holed tip, depth graduations and single-use for intrauterine insemination), it falls into the same category as the cannulas from AINSEBLUE (references 770113 and 770408) and AINSEWHITE (770219 and 770220), as well as the Frydman-type seminal transfer systems on the European market. To confirm an exact equivalence with another manufacturer’s reference, contact our technical-commercial department.
Selection tips and variants of interest
To choose the most suitable catheter, assess the cervical canal calibre and uterine morphology of each patient. This mini CH5 model without introducer or stylet (PS1260500) is the economical, versatile option recommended for standard procedures with good cervical accessibility and smaller-calibre cervices. If a stable guide is required during insertion, select the version with introducer (PS1270500); if the anatomy presents marked angulations and the distal end needs to be pre-formed, the versions with stylet (PS4130500) or with introducer and stylet (PS4160500) offer additional guidance. For larger sample volumes, opt for the CH6 variants (PS1260600, PS1270600, PS4130600 and PS4160600). All models share gamma radiation sterility, single-use and presentation in a box of 25 units. These catheters are used alongside the brand’s fertility instruments, such as sterile hysterometers for prior measurement of the uterine cavity, ensuring correct selection of calibre and insertion length. Consult our technical-commercial team at Cahnos for advice on selection and volume contracting for your centre.