We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

AINSEBLUE T Intrauterine Artificial Insemination Cannula, Conical Open Tip, Ø ext. 2 mm x 174 mm, Sterile (Box of 24 units) Ref. 770408

213,60 €

AINSEBLUE T cannula for intrauterine artificial insemination with conical open tip, sterile and single-use. Outer diameter 2 mm, inner diameter 1.3 mm and length 174 mm, with a rigid proximal portion and a flexible distal portion, measurement scale 50-60-70 mm, Luer Lock connector and two orientation wings. Made of transparent radiopaque material, sterilised by ethylene oxide (CE 0051) and subjected to embryotoxicity (MEA) and endotoxin (LAL) controls. Presentation in a box of 24 units in individual packaging. Ref. 770408.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
770408

Description

1. Introduction

The AINSEBLUE T cannula (Ref. 770408) is a disposable and sterile device designed to facilitate the transfer of prepared semen into the uterine cavity in artificial insemination (AI) procedures. Its open conical tip configuration allows a direct and controlled release of seminal fluid, while the transparent radiopaque body gives the specialist optimal visual and ultrasound control during placement. It is the reference tool for assisted reproduction clinics, gynaecology units and fertility laboratories that require reliable, reproducible and traceable performance.

2. Technical explanation of the procedure

Intrauterine artificial insemination consists of depositing a sample of washed, capacitated and prepared sperm directly into the uterine cavity at the optimal time of the ovulatory cycle. The AINSEBLUE T cannula has a single lumen and two different degrees of flexibility: a rigid proximal portion that facilitates introduction through the cervix and a soft, flexible distal portion that allows delicate, atraumatic seminal transfer. The measurement scale (50-60-70 mm) marked on the body determines the depth of insertion, and the female Luer lock connector acts as a handle, ensuring a secure connection to the syringe. The two lateral wings, aligned with the tip, provide orientation during positioning. Procedure for use: insert the speculum, clean the cervical mucus, load the semen into a syringe and connect it to the fitting; advance the cannula through the cervix to approximately the fundus of the uterus and inject in slow, intermittent pulses to minimise reflux, keeping the patient in a reclined position for about 15-20 minutes. Warning: do not exceed the depth previously measured with the hysterometer to avoid the risk of perforation. Do not reuse; use only if the packaging is intact and immediately after opening. Single-use device, exclusively for specialised medical personnel, which must not be used for in vitro fertilisation or intratubal gamete transfer.

3. Technical Specifications

Characteristic Specification
Model Ainseblue-T (AINSEBLUE / FERTIRAM range)
Reference / SKU 770408
Type Intrauterine artificial insemination cannula
Tip Open conical (tapered open tip)
Outer diameter 2 mm
Inner diameter 1.3 mm
Length 174 mm
Measurement scale 50 – 60 – 70 mm
Connector Female Luer lock
Flexibility Rigid proximal portion + soft, flexible distal portion
Lumen Individual
Radiopaque Yes (transparent and radiopaque)
Orientation wings 2 lateral wings aligned with the tip
Sterilisation Ethylene oxide (EtO) – CE marking 0051
Use Single-use (disposable)
Packaging Individual sterile pack
Presentation Box of 24 units
Quality controls Embryotoxicity (MEA test) and bacterial endotoxins (LAL test)
Indication Intrauterine artificial insemination with prepared semen
Not indicated for Not for IVF or intratubal gamete transfer

4. Equivalences and Cross-References

Reference 770408 has been verified against the manufacturer’s official catalogue (AINSEBLUE-T / FERTIRAM range), where it appears with identical characteristics: outer diameter 2 mm, inner diameter 1.3 mm, length 174 mm and presentation of 24 units in individual packaging. The AINSEBLUE T cannula is functionally positioned in the category of single-use intrauterine insemination cannulas. Listed below are references from other manufacturers on the European and American markets, verified in their official sources, offered as a functional category comparison and not as interchangeable 1:1 equivalents:

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Laboratoire CCD IUI Standard (intrauterine cannula) 120400S Comparable by category (not interchangeable 1:1) Ø ext 2.10 mm, Ø int 1.70 mm, length 17 cm, flexible tip of 4.5 cm with 2 lateral openings; polyethylene; box of 25 units. The outlet is through lateral openings as opposed to the open conical tip of the AINSEBLUE T.
CooperSurgical Select IUI SM400 Comparable by category (not interchangeable 1:1) 17 cm x 2.1 mm, 0.34 cc, double opening (2 orifices); box of 25 units. Lateral outlet geometry different from the open tip.
Cook Medical Insemi-Cath J-IUIC-351300 (G16707) Comparable by category (not interchangeable 1:1) Distal tip with natural camber and open end without positioner; but calibre 3.5 Fr (≈1.17 mm) and length 13 cm, notably smaller; nylon; box of 20 units.
Gynemed (Gynétics) IUI Standard 4220 Standard Comparable by category (not interchangeable 1:1) Length 206 mm, Ø ext 1.85 mm, 2 distal lateral ports, Luer lock connector; box of 25 units. Greater length and lateral outlet compared with the AINSEBLUE T.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. The third-party references indicated are offered as a functional category comparison and require verification of calibre, tip geometry and centre protocol before any substitution.

5. Selection tips and variants of interest

For correct selection, measure the depth of the uterine cavity beforehand with a sterile hysterometer and do not exceed that reference during insertion. The Ainseblue-T (770408) cannula is the recommended option when semen outflow through an open tip is preferred, with direct passage and no lateral holes. If you prefer distribution of the seminal fluid through two lateral holes in the tip, the Ainseblue (770113) from the same range is available. For placement with a steel mandrel or soft graduated cannula, the company offers the Ainsewhite (770219) and Ainsegrey (770220) variants. As an alternative within the assisted reproduction range itself, the intrauterine insemination catheters PM-LIFE (CH5/CH6, 175 mm) cover gauge and guidance needs with introducer or mandrel. All units are single-use, sterile and individually packaged; contact our technical-commercial team at Cahnos for special conditions by volume or specific protocols for your centre.

Additional information

Reference

770408

Model

AINSEBLUE T

Product type

Intrauterine artificial insemination cannula

Inner diameter

1.3 mm

Tip

Open conical (tapered open tip)

Flexibility

Rigid proximal portion and flexible distal portion

Connection

Female Luer lock connector

Orientation

Two lateral wings

Material

Transparent radiopaque plastic

Sterilisation

Ethylene oxide (EtO), CE marking 0051

Use

Single-use (disposable)

Quality tests

Embryotoxicity (MEA) and bacterial endotoxins (LAL)

Presentation

Box of 24 units in individual packaging

Indications

Intrauterine artificial insemination with prepared semen

Measurement scale

50-60-70 mm

Connector

Female Luer lock

Lumen

Individual

Quality controls

Embryotoxicity test (MEA) and bacterial endotoxins (LAL)

Not indicated for

Not for IVF or intratubal gamete transfer

Diametro mm

2 mm

Longitud

17.4 cm

Reviews

There are no reviews yet.

Be the first to review “AINSEBLUE T Intrauterine Artificial Insemination Cannula, Conical Open Tip, Ø ext. 2 mm x 174 mm, Sterile (Box of 24 units) Ref. 770408”

Your email address will not be published. Required fields are marked *