Elastomeric infusion pump ELASPUMP® 60 ml, single-use and free from DEHP, PVC and latex, with variable flow rate of 4 speeds (2-5-7-12 ml/h). Its silicone elastomer drives the drug at a calibrated and selectable flow rate without the need for batteries or maintenance, ideal for administering medication intravenously, arterially, epidurally and subcutaneously in chemotherapy, pain therapy, antiviral and antibiotic treatments. It incorporates a one-way filling valve, male luer-lock connector with hydrophobic filter, in-line particle filter, colour-coded labelling and full traceability. A single device allows different regimens to be protocolised and simplifies warehouse management.

Pedido mínimo de 60 unidades por condiciones del fabricante.

International shipping. Import duties and taxes are payable by the recipient.

Reference
093001/M1

Description

1. Introduction: safe, precise infusion without electronic equipment

The ELASPUMP® 60 ml Elastomeric Infusion Pump (Ref. 093001/M1) is the single-use, variable-flow solution your department needs to administer drugs with precision, safety and complete independence from electronic equipment. Thanks to its 4-speed selector (2-5-7-12 ml/h), a single device allows different infusion regimens to be standardised without having to change the reference, simplifying stock management and reducing the cost per treatment.

Designed for hospitals, clinics, home hospitalisation units and outpatient care centres, it guarantees continuous, reliable infusion, with no batteries, no maintenance and no risk of cross-contamination between patients. Manufactured without phthalates (DEHP), without PVC and without latex, it is especially suitable for oncology therapies, pain therapy and long-term treatments.

2. Technical description and operating principle

The ELASPUMP® pump consists of a silicone elastomer housed inside a hermetic, rigid, transparent casing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. Its operating principle is based on the elastic recovery pressure of the elastomer, which drives the medication through the tubular system at a constant, calibrated flow rate, selectable from 4 infusion speeds by means of a regulator integrated into the infusion line.

  • One-way filling valve: closed-circuit with flat bottom, compatible with a standard syringe, which facilitates loading of the elastomer.
  • Hydrophobic filter: located over the male luer-lock connector cap, it allows the tubular set to be primed without removing the cap, preserving internal sterility until actual use.
  • In-line particle filter: retains impurities and guarantees the purity of the administered drug.
  • Removable sliding clamp: easy to remove if necessary.
  • Colour-coded label: with the flow rate printed for quick, immediate identification of the selected flow.
  • Patient label: designed for easy personalisation of the treatment.
  • Full traceability: variable data and product code printed on the outer casing and on the pump body.

3. Technical Specifications

Characteristic Specification
Brand ELASPUMP®
Reference 093001/M1
Capacity 60 ml
Flow type Variable with 4-speed selector
Infusion speeds 2 – 5 – 7 – 12 ml/h
Drive mechanism Silicone elastomer in rigid and transparent casing
Filling system Closed-circuit one-way valve, compatible with standard syringe
Connection Male Luer-lock with cap and hydrophobic filter
Filtration Hydrophobic filter + in-line particle filter
Routes of administration Intravenous, arterial, epidural and subcutaneous
Clinical indications Chemotherapy, pain therapy, antiviral and antibiotic treatments
Power supply Does not require battery or electrical power source
Use Single-use, sterile
Composition DEHP-free, PVC-free, latex-free

Approximate infusion duration (60 ml volume)

Selected flow rate Approximate duration
2 ml/h Approx. 1 day and 6 hours (30 hours)
5 ml/h Approx. 12 hours
7 ml/h Approx. 8 hours and 34 minutes
12 ml/h Approx. 5 hours

Indicative values calculated at full volume; actual duration may vary slightly depending on conditions of use and the characteristics of the drug.

4. Equivalences and Cross-References

The ELASPUMP® 60 ml variable-flow (Ref. 093001/M1) belongs to the range of variable-flow elastomeric pumps in the ELASPUMP® family and complements the following references available at Cahnos:

Reference Description
093001/M1 ELASPUMP® 60 ml, variable flow with 4 speeds (2-5-7-12 ml/h), DEHP-free (current product)
093001/M2 ELASPUMP® 60 ml, variable flow with 8 speeds (selector 0-1-2-3-4-5-6-7), DEHP-free
093001/M3 ELASPUMP® 60 ml, variable flow with 8 speeds (0-2-4-6-8-10-12-14 ml/h), DEHP-free
093001/4 ELASPUMP® 60 ml continuous flow (2 ml/h = 1 day + 6 hours)
093001/5 ELASPUMP® 60 ml continuous flow (4 ml/h = 15 hours)
093002/M2 · M3 ELASPUMP® 100 ml, variable flow with 8 speeds, DEHP-free
093004/M2 · M3 ELASPUMP® 200 ml, variable flow with 8 speeds, DEHP-free
093005/M2 · M3 ELASPUMP® 275 ml, variable flow with 8 speeds, DEHP-free

With its 60 ml capacity, pressurised elastomer system with luer-lock connector and flow regulator, this device is comparable to the disposable adjustable-flow elastomeric pumps used in controlled analgesia and ambulatory infusion by other manufacturers (elastomer-type systems with flow dial), and is interchangeable in most clinical protocols for continuous infusion and patient-controlled analgesia (PCA). Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.

5. Selection tips and variants of interest

  • Volume to be infused: the 60 ml version is ideal for short-to-medium duration therapies (from around 5 hours to more than 1 day depending on the selected flow rate). For larger volumes, versions of 100 ml, 200 ml and 275 ml are available.
  • Required flow rate: the variable-flow model with 4 speeds (2-5-7-12 ml/h) offers excellent flexibility for adjusting the speed during treatment or standardising different regimens with a single product code. If you need an even wider range of flow rates, consider the 8-speed versions (Refs. 093001/M2 and M3).
  • Fixed protocols: if your regimen is constant, the continuous-flow versions (Refs. 093001/4, 093001/5 and others in the range) may be more economical.
  • Photosensitive drugs: for light-sensitive medications, choose the ELASPUMP® versions with UV protection (Refs. 093002/5/B and 093005/8/B).
  • Accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.

Contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.

Additional information

Reference

093001/M1

Flow type

Variable with 4-speed selector (2-5-7-12 ml/h)

Drive mechanism

Silicone elastomer in hermetic, rigid and transparent housing

Filling system

Closed-circuit one-way valve, compatible with standard syringe

Connection

Male Luer-lock with cap and hydrophobic filter

Filtration

Hydrophobic filter + in-line particle filter

Routes of administration

Intravenous, arterial, epidural and subcutaneous

Indications

Chemotherapy, pain therapy, antiviral and antibiotic treatments

Approximate duration

2 ml/h ≈ 30 h; 5 ml/h ≈ 12 h; 7 ml/h ≈ 8 h 34 min; 12 ml/h ≈ 5 h

Power supply

No battery or power source

Sterilisation

Single-use, sterile

Composition

DEHP, PVC and latex free

Brand

ELASPUMP®

Capacidad

60 ml

Flujo por hora

4 Speeds (2-5-7-12)