1. Introduction
This original manufacturer replacement (Ref. 35208) gives you the peace of mind of working with genuine components in your infusion pump from the 35205 series. It combines in a single reference the rechargeable nickel-metal hydride (Ni-MH) battery and the control electronic board, so that the renewal of the power supply system is resolved with original parts and full compatibility. For large orders you can request a quote: contact our technical-commercial team to confirm suitability for your equipment and supply conditions.
2. Technical Explanation
The infusion pump Ref. 35205 (SP-8800 family) operates both on mains power and rechargeable battery, which facilitates patient mobility and ensures continuity of infusion during power cuts. With use, the Ni-MH battery capacity degrades progressively and the time comes to replace it. This reference 35208 is specifically designed for units manufactured up to June 2023, identifiable by the serial number with prefix OD23F.
The set includes both the Ni-MH battery and the electronic board, so the power supply system is completely renewed. Replacement is not a simple maintenance operation: it requires opening the equipment, handling electronic components and carrying out subsequent functional checks. For this reason, the manufacturer establishes that installation must be carried out with qualified technical assistance, by authorised personnel and following the official procedure.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | No medical device |
Replacement specifications
| Manufacturer reference | 35208 |
|---|---|
| Component type | Rechargeable Ni-MH battery + electronic board |
| Compatibility | Infusion pump Ref. 35205 (SP-8800) |
| Application range | Units manufactured up to June 2023 |
| Applicable serial number | Prefix OD23F |
| Replaces | Ref. 35210 (Ni-MH battery, discontinued) |
| Installation | Requires qualified technical assistance |
| Presentation | 1 unit |
| Classification | Replacement (not a medical device) |
Available references
| Reference | Description |
|---|---|
| 35208 | Ni-MH battery + electronic board for 35205, up to June 2023 (SN OD23F) – product of this datasheet |
| 35209 | Ni-MH battery for 35205, from July 2023 (SN OD23G) |
| 35210 | Ni-MH battery for 35205, up to June 2023 (SN OD23F) – discontinued, replaced by 35208 |
| 35205 | Infusion pump (SP-8800) for which the replacement is intended |
4. Equivalences and Cross-References
This battery + board set is a replacement for exclusive use in equipment; no direct 1:1 equivalents have been found with other manufacturers for this specific combination of battery and electronics, so no unverified cross-references are indicated. Within the range itself, the related references are: 35210 (Ni-MH battery for 35205 up to June 2023, SN OD23F, discontinued and replaced by 35208), 35209 (Ni-MH battery for 35205 from July 2023, SN OD23G, for later units) and 35205 (infusion pump from the SP-8800 series for which the replacement is intended). Always check the serial number of your equipment before ordering: units with prefix OD23G require reference 35209 and not 35208. If in any doubt, contact our technical department.
5. Selection tips and variants of interest
Before ordering this replacement, locate the rating plate on your pump and note the serial number: if the prefix is OD23F (up to June 2023), this reference 35208 is the correct one. If your equipment is later (OD23G, from July 2023), you should order the battery Ref. 35209, as it does not share the same electronics. Always contract the replacement with authorised technical personnel: the manufacturer expressly states that the change requires technical assistance. Also check the availability of other accessories and spare parts in the infusion pump range in our catalogue. Request a quote from our commercial team, indicating the serial number of your equipment.