We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Insulin Pen Injector (Insulin Pen Injector) – Compatible with Needles ISO 11608-2 – Ref. 23845

Price on request

Insulin pen injector (ref. 23845): class II B medical device for subcutaneous insulin administration in the management of diabetes. Compatible with needles conforming to standard ISO 11608-2, ensuring a secure coupling and reliable dosing throughout the treatment. It is supplied as a single unit (1 pc) and is the ideal solution for pharmacy, primary care, endocrinology and diabetes education programmes. At Cahnos you have the complementary range of insulin pen needles and BD Micro-Fine™ (4, 5 and 8 mm) to complete the injection system. For large orders you can request a quote: request conditions from your technical-commercial advisor.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM23845

You will also find it in

Description

1. Insulin Pen Injector – The complete solution for daily therapy

The insulin pen injector (ref. 23845) is the reference injection device for subcutaneous insulin administration in patients with diabetes. It combines an ergonomic and precise design with maximum reliability in daily dosing, facilitating treatment adherence in hospital settings, endocrinology consultations, community pharmacies and diabetes education programmes.

It is the comfortable and safe alternative to the classic syringe: it allows prescribed doses to be administered with greater precision and patient acceptance, improving the quality of life of those who need multiple injections a day. For large orders you can request a quote: contact the technical-commercial team at Cahnos for supply conditions for your centre.

2. Technical explanation of the device

The insulin pen injector is a pen-type injector designed for subcutaneous insulin injection. Its operation is based on a dosing mechanism that expels the selected dose by means of plunger pressure, allowing exact and repeatable control of the amount administered in each injection.

The device is designed to work exclusively with needles conforming to standard ISO 11608-2, the international standard that regulates the requirements for pen-type injector needles. This ensures compatibility of the coupling system (thread) and sterility of the injection pathway, as well as reliable mechanical performance throughout the device’s useful life. It is the central component of a complete injection system that is completed with disposable and sterile replacement needles.

3. Technical Specifications

Data verified according to the manufacturer’s catalogue (Product_DB) for reference 23845:

Product data

Manufacturer GIMA
Manufacturer reference 23845
SKU Cahnos GM23845
Sales unit 1 pc (1 unit)
Device type Medical device (Medical device)
Device class II B
CND A020203
EAN 6951592134199
Compatibility Needles conforming to standard ISO 11608-2
Application Subcutaneous insulin administration

Available references

Reference Description
23845 (GM23845) Insulin pen injector (this product)

4. Equivalences and Cross-References

No validated 1:1 equivalence table has been found in reliable sources cross-referencing reference 23845 with exact codes for pen injectors from other manufacturers. Therefore, it is not recommended to replace this reference without prior verification of the actual device.

A technical compatibility equivalence is indeed established: the Ref. 23845 pen is compatible with all needles conforming to standard ISO 11608-2, including the insulin pen needles marketed by Cahnos, such as the universal needles (refs. GM23840, GM23841, GM23842 and GM23843) and the BD Micro-Fine™ range (refs. GM23850 of 4 mm – 32G, GM23851 of 5 mm – 31G and GM23852 of 8 mm – 31G). In the event of any substitution in a tender, always check the needle coupling system and the conformity of the assembly with ISO 11608-2.

5. Selection tips and variants of interest

To complete the injection system with this pen, select the needle according to the thickness of the patient’s subcutaneous tissue and the prescribed technique: 4 mm and 32G profiles (GM23850) for fine tissue and the paediatric population; 5 mm and 31G (GM23851) as a short general-use profile; and 8 mm and 31G (GM23852) for most adult patients. The universal needles (GM23840 to GM23843) are supplied in boxes of 100 units for continuous supply.

Remember that pen needles are single-use and sterile: they must be disposed of after each administration in an approved container for sharp and cutting healthcare waste. The pen device is reusable; always follow the manufacturer’s instructions for use, cleaning and storage. For institutional orders, purchasing centres or tenders, contact your technical-commercial advisor at Cahnos to confirm availability and conditions.

Additional information

Manufacturer reference

23845

Sales unit

1 pc (1 unit)

Device type

Medical device (Medical device)

CND code

A020203

EAN

6951592134199

Compatibility

Needles conforming to standard ISO 11608-2

Application

Subcutaneous insulin administration

Use

Pen-type injection device

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Insulin Pen Injector (Insulin Pen Injector) – Compatible with Needles ISO 11608-2 – Ref. 23845”

Your email address will not be published. Required fields are marked *