Description
1. Introduction
The safety intravenous catheter with wings and injection port Nipro 22G x 25 mm is the peripheral venous access solution designed for healthcare environments where the safety of the professional and the patient is a priority. It incorporates a passive protection system that covers the needle during its withdrawal, minimising the risk of accidental needlestick injuries and blood contamination in sharps waste management. An essential tool for hospitals, clinics, emergency services, oncology and home care that seek to meet current occupational risk prevention requirements (Directive 2010/32/EU on sharps).
2. Technical Explanation
This safety peripheral catheter combines a design with wings (which facilitate grip, stabilisation and fixation after cannulation) with an integrated injection port, which allows administering bolus medication or performing system flushes without disconnecting the infusion line. The safety mechanism retracts the hollow needle into the protector upon withdrawal, so that the contaminated tip is never exposed. The radiopaque cannula guarantees its location by imaging if necessary, and the Luer-Lock connector ensures a connection with standard infusion equipment on the market.
With a 22G gauge and 25 mm length, it is the recommended choice for paediatric, geriatric and adult patients with small to medium-calibre veins, as well as for short and medium-duration therapies: administration of fluids, drugs, chemotherapy, blood products and transfusions at controlled rates.
3. Technical Specifications
| Brand | Nipro |
| Reference (SKU Cahnos) | NIC-SF-2225PWP-ET |
| Device type | Peripheral intravenous safety catheter |
| Gauge | 22G |
| Needle outer diameter | 0.9 mm |
| Catheter length | 25 mm |
| Design | With wings and injection port (winged + ported) |
| Safety mechanism | Passive protection needle guard |
| Connection | Standard female Luer-Lock |
| Cannula material | Radiopaque flexible polymer, single-use |
| Sterility | Sterile, single-use |
| Presentation | Box of 50 units |
| Applications | Injections, infusions, transfusions and sample collection |
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer Nipro for this catheter; the reference is marketed under Cahnos’s own code (NIC-SF-2225PWP-ET) within the safety range with wings and injection port. At market level, the product is comparable by category with other safety intravenous catheters 22G x 25 mm with injection port; it is recommended to verify the technical data sheet and waste management requirements of each centre before substituting one reference for another.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Terumo | Surshield™ Versatus-WP (22G, 0.9 x 25 mm, blue) | SR+DS2225PD | Comparable by category (not interchangeable 1:1) | Same gauge and length, with wings and injection port, box of 50 units; material and protection mechanism specific to Terumo. Verify the centre’s waste protocol. |
| B. Braun | Introcan Safety®-W (22G, 0.9 x 25 mm, PUR) | 4253540-01 | Comparable by category (not interchangeable 1:1) | With wings, without injection port in this variant; same gauge and length. Verify need for injection port. |
Pending confirmation with the technical department of the manufacturer’s official cross-reference table before use in public tender.
5. Selection tips and variants of interest
To choose the appropriate gauge, consider the vein type and therapy: the 22G (0.9 mm) is versatile and compatible with most infusions and transfusions in adults and paediatrics; for very small or fragile veins consider the 24G (lower flow), while for large volumes or rapid transfusions in adults with good access, gauges 20G, 18G or 16G offer higher flow rate. At Cahnos you have the same Nipro safety range in other gauges and lengths (e.g. 22G x 32 mm, 20G x 32/50 mm, 18G x 32/50 mm, 16G x 50 mm, 24G x 19/25 mm). As it is a safety device with needle guard, it is especially indicated for emergencies, hospitalisation, oncology and home care, where prevention of accidental needlestick injuries is critical.