Description
1. Introduction
The 200 cm syringe pump infusion extension line (Ref. PMFPS200F) is the essential replacement accessory for completing infusion circuits in hospitalisation, ICU, emergency, oncology and paediatrics services. Its great length allows the pump to be moved away from the patient with total freedom of movement, maintaining a leak-proof, safe and secure connection throughout the therapy.
Made from BPA-free medical-grade PVC, it combines flexibility, precision and universal compatibility. It is presented in a box of 300 units, making it the most cost-effective and reliable replacement solution for hospital purchases, ward stock and public tenders, with immediate dispatch from warehouse.
2. Technical Explanation
This extension line acts as a line extension between the syringe loaded in the pump and the patient’s catheter or vascular access, extending the circuit without the need to disconnect the infusion. Its flexible tube of gauge Ø1.5 x 2.5 mm (1.5 mm internal diameter and 2.5 mm external diameter) offers a stable and continuous flow, suitable for the low and medium flow rates typical of syringe pumps, with low resistance to the passage of the drug.
The fixed Luer Lock connectors present at both ends (distal male and proximal female) ensure a rigid screw fixation, preventing accidental disconnections and maintaining leak-tightness even during prolonged therapies. Being BPA-free and single-use, it is suitable for the administration of drugs and solutions in demanding clinical environments, minimising the risk of interactions with the material.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference | PMFPS200F |
| SKU | 0322029 |
| Product type | 1-way infusion extension line for syringe pump |
| Length | 200 cm |
| Tube diameter | Ø1.5 x 2.5 mm (internal Ø 1.5 mm / external Ø 2.5 mm) |
| Proximal connector | Female Luer Lock (fixed) |
| Distal connector | Male Luer Lock (fixed) |
| Material | Medical-grade PVC |
| Composition | BPA-free |
| Approximate priming volume | ≈ 3.5 ml (estimated based on internal diameter and length; manufacturer does not declare official value) |
| Maximum pressure | Not declared by the manufacturer |
| Compatibility | Syringe pumps and standard syringes with Luer Lock connection |
| Use | Single-use (disposable) |
| Sterility | Not specified (consult technical department) |
| Presentation | Box of 300 units |
4. Equivalences and Cross-References
There is no cross-reference equivalence table validated by the manufacturer for this reference against other brands; the following comparisons are offered for guidance only and must be confirmed with the Cahnos technical department before use in tenders or stock replacement.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos | PVC extension line 200 cm fixed Luer Lock Ø1.5×2.5 | PMFPS200F (current product) | Reference product | BPA-free PVC, Ø1.5 x 2.5 mm, fixed nut, box of 300 units |
| B. Braun | Original Perfusor® Line PVC, 200 cm, 1.5 x 2.7 mm | 8722862 (B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | PVC, Luer Lock, internal Ø 1.5 mm and external 2.7 mm, priming volume 3.61 ml, max. pressure 2.0 bar, pack of 100 units |
| Fresenius Kabi | Injectomat® Line PVC, 200 cm | 9014342 (indicative, verify with manufacturer) | Comparable by category, not interchangeable 1:1 | Line for syringe pump with Luer Lock connector, max. pressure 2 bar; verify diameter and connector configuration in official datasheet |
| Fresenius Kabi | Injectomat® Line PE, 200 cm | 9004142 (Fresenius Kabi catalogue) | Comparable by category, not interchangeable 1:1 | PVC-free polyethylene, Ø1.0 x 2.0 mm, priming volume ≈ 0.8 ml/m, max. pressure 2 bar |
| Vygon | LectroCath PE, 200 cm | 1155.20 (Vygon catalogue) | Comparable by category, not interchangeable 1:1 | Polyethylene, internal Ø 1.0 mm, female/male Luer Lock, colour-coded clip, box of 50 units |
Within the Cahnos catalogue, the PMFPS_F series shares material (BPA-free PVC), internal diameter (Ø1.5 mm) and connector (fixed male/female Luer Lock), differing only in length: PMFPS25F (25 cm), PMFPS50F (50 cm), PMFPS100F (100 cm), PMFPS150F (150 cm) and PMFPS200F (200 cm). They are interchangeable in performance by choosing the length according to the application. The PMFMPS_F series (e.g. PMFMPS200F) maintains the same tube and material but with a rotating nut Luer Lock; the D1F series offers microbore tube Ø1 x 2.5 mm (lower residual volume) and the PE series uses PVC-free polyethylene.
Not verified: there is no cross-reference table validated by the manufacturer against other brands; it is recommended to consult the Cahnos technical department before fixing the replacement in public procurement specifications.
5. Selection tips and variants of interest
- Length: the 200 cm version is ideal when the pump needs to be moved away from the patient or to facilitate mobility in beds, chairs and transfers. For shorter circuits, consider the 25, 50, 100 or 150 cm versions of the same PMFPS_F series.
- Connector: the fixed nut provides a rigid fixation without rotation; if you prefer a thread that does not transmit torsion to the tube during patient movements, consult the series with rotating Luer Lock (PMFMPS_F).
- Diameter: the Ø1.5 x 2.5 mm tube offers good flow; if your protocol requires minimising residual volume and priming (high-risk medication), consider the D1F series with Ø1 x 2.5 mm tube.
- Material: if your protocol requires avoiding PVC or plasticisers, consider the polyethylene lines (PMFPS_PE series) available in the Cahnos infusion catalogue.
- Compatibility: always verify the pump, syringe and three-way stopcocks of the circuit; this extension line is compatible with standard syringes and syringe pumps with Luer Lock connection on the market.
- Accessories: combine it with three-way stopcocks, non-return valves and other infusion accessories from the catalogue to adapt the circuit to each therapy.
For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples.





Reviews
There are no reviews yet.