We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

200 cm Syringe Pump Infusion Extension Line | Mobile Male/Female Luer Lock Ø1.5×2.5 mm BPA-free PVC | Box of 125 units Ref. PMFMPS200F

52,50 €

200 cm syringe pump infusion extension line with mobile male/female Luer Lock connectors (rotating nut) and BPA-free medical-grade PVC tubing Ø1.5×2.5 mm. Ideal for extending the line between the syringe loaded in the pump and the patient’s vascular access in ICU, hospitalisation and critical care, with a leak-tight threaded connection that prevents accidental disconnections and tube kinking. Compatible with virtually all syringe pumps and standard syringes with Luer Lock connection. Presentation in box of 125 units, stock format for hospital purchasing and tenders. Ref. PMFMPS200F.

International shipping. Import duties and taxes are payable by the recipient.

Reference
PMFMPS200F

Description

1. Introduction

The infusion extension line for syringe pump PMFMPS200F is the essential replacement accessory to complete infusion circuits in hospital wards, ICU, A&E, oncology and paediatrics. Its 200 cm length allows the pump to be placed away from the patient with complete freedom of movement, maintaining a leak-tight, safe and unobstructed connection throughout the therapy.

Manufactured from BPA-free medical-grade PVC, it guarantees compatibility with virtually all syringe pumps and infusion systems on the market. Supplied in a box of 125 units, it becomes the most cost-effective and reliable replacement solution for hospital purchasing, ward stock and public tenders, with immediate dispatch from the warehouse.

2. Technical Explanation

This extension line acts as a single-lumen extension between the syringe loaded in the pump and the patient’s catheter or vascular access, extending the circuit without the need to disconnect the infusion. Its flexible tubing with a gauge of Ø1.5 x 2.5 mm (1.5 mm internal diameter and 2.5 mm external diameter) provides a stable and continuous flow, suitable for the low and medium flow rates typical of syringe pumps, with low resistance to drug passage.

The rotating Luer Lock (swivel nut) on both ends secures the connection with a thread, preventing accidental disconnections, while the free rotation of the collar prevents the tubing from twisting or kinking when the patient or pump moves. Being BPA-free and single-use, it is suitable for the administration of drugs and solutions in demanding clinical environments, minimising the risk of material interactions.

3. Technical Specifications

Reference PMFMPS200F
Product type 1-way infusion extension line for syringe pump
Length 200 cm
Tube diameter Ø1.5 x 2.5 mm (internal Ø 1.5 mm / external Ø 2.5 mm)
Proximal connector Female Luer Lock (rotating collar)
Distal connector Male Luer Lock (rotating collar)
Material Medical-grade PVC
Composition BPA-free
Approximate priming volume ≈ 3.5 ml (estimated based on internal diameter and length; manufacturer does not declare official value)
Maximum pressure Not declared by the manufacturer
Compatibility Syringe pumps and standard syringes with Luer Lock connection
Use Single-use (disposable)
Sterility Not specified (consult technical department)
Presentation Box of 125 units

4. Equivalences and Cross-References

Exact reference equivalent (same series): within the Cahnos catalogue, the PMFMPS_F series shares material (BPA-free PVC), internal diameter (Ø1.5 mm) and connector (male/female rotating Luer Lock), differing only in length: PMFMPS25F (25 cm), PMFMPS50F (50 cm), PMFMPS100F (100 cm), PMFMPS150F (150 cm) and PMFMPS200F (200 cm). They are interchangeable in performance, choosing the length according to the application.

Comparable by category (not interchangeable 1:1): the PMFMPS_D1F series (e.g. PMFMPS200D1F) retains the rotating Luer Lock but with Ø1 x 2.5 mm tubing (lower residual volume); the PMFPS_F series offers a fixed Luer Lock; and the PMFPS_PE001 series uses PVC-free polyethylene. In the general market, syringe pump lines from other manufacturers differ at least in diameter or connector configuration:

Manufacturer / Brand Family / Model Code / SKU Equivalence level Technical differences / Remarks
B. Braun Original Perfusor® Line PVC, 200 cm 8722862 Comparable by category, not interchangeable 1:1 PVC, male/female Luer Lock; differs in Ø 1.5 x 2.7 mm and priming volume 3.61 ml; max. pressure 2.0 bar; box of 100 units
B. Braun Original Perfusor® Line PVC (small tubing), 200 cm 8745919N Comparable by category, not interchangeable 1:1 PVC, internal diameter 0.9 mm with external Ø 1.9 mm; priming 1.42 ml; max. pressure 2.0 bar
Fresenius Kabi Injectomat® Line PVC, 200 cm 9014342 (indicative, verify) Comparable by category, not interchangeable 1:1 Syringe pump line with Luer Lock connector; verify diameter and connectors in official data sheet
Vygon LectroCath PE, 200 cm 1155.20 Comparable by category, not interchangeable 1:1 Polyethylene with Ø 1.0 x 2.0 mm and priming ~2.0 ml; not PVC
Vygon PVC Extension Tube Male/Female Luer Lock, 200 cm 000220200 Comparable by category, not interchangeable 1:1 PVC but Ø 2.5 x 4.0 mm (larger diameter); not a microbore line for syringe pump
Codan Syringe Pump Extension Set (microbore) 71.4356 (100 cm) Comparable by category, not interchangeable 1:1 PVC, internal diameter 0.9 mm, micro male/female Luer Lock; verify length and clamp

Not verified: there is no cross-reference equivalence table validated by the manufacturer for this reference against other brands; the above comparisons are provided for guidance and must be confirmed with the technical department of Cahnos before establishing substitution in public procurement specifications or care protocols.

5. Selection tips and variants of interest

Length: the 200 cm version is ideal when the pump needs to be placed away from the patient or to facilitate mobility in beds, chairs and transfers. For shorter circuits, consider the 25, 50, 100 or 150 cm versions of the same PMFMPS_F series.

Diameter: the Ø1.5 x 2.5 mm tubing provides good flow for standard infusions; if your protocol requires minimising residual volume and priming (high-risk medication), consider the D1F series with Ø1 x 2.5 mm tubing (e.g. PMFMPS200D1F).

Connector: the rotating collar facilitates threading without transmitting torsion to the tubing; if you prefer a rigid fixation without rotation, consult the versions with fixed Luer Lock (PMFPS_F series, e.g. PMFPS200F).

Material: if your protocol requires avoiding PVC or plasticisers, consider the polyethylene lines (PMFPS_PE001 series, e.g. PMFPS200PE001) or the opaque PVC versions for light-sensitive drugs (PMFTJPS200F).

Compatibility: always check the pump, syringe and three-way stopcocks in the circuit; this extension line is compatible with standard syringes and syringe pumps with Luer Lock connection on the market. For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples.

Additional information

Reference

PMFMPS200F

Product type

1-way infusion extension line for syringe pump

Tube diameter

Ø1.5 x 2.5 mm

Inner diameter

1.5 mm

Proximal connector

Female Luer Lock (rotating collar)

Distal connector

Male Luer Lock (rotating collar)

Material

Medical-grade PVC

Composition

BPA-free

Approximate priming volume

≈ 3.5 ml (estimated; manufacturer does not declare official value)

Maximum pressure

Not declared by the manufacturer

Compatibility

Syringe pumps and standard syringes with Luer Lock connection

Use

Single-use (disposable)

Sterility

Not specified (consult technical department)

Presentation

Box of 125 units

Longitud

200 cm

Diametro mm

25 mm

Reviews

There are no reviews yet.

Be the first to review “200 cm Syringe Pump Infusion Extension Line | Mobile Male/Female Luer Lock Ø1.5×2.5 mm BPA-free PVC | Box of 125 units Ref. PMFMPS200F”

Your email address will not be published. Required fields are marked *