Description
1. Introduction
The infusion extension line for syringe pump PMFMPS200F is the essential replacement accessory to complete infusion circuits in hospital wards, ICU, A&E, oncology and paediatrics. Its 200 cm length allows the pump to be placed away from the patient with complete freedom of movement, maintaining a leak-tight, safe and unobstructed connection throughout the therapy.
Manufactured from BPA-free medical-grade PVC, it guarantees compatibility with virtually all syringe pumps and infusion systems on the market. Supplied in a box of 125 units, it becomes the most cost-effective and reliable replacement solution for hospital purchasing, ward stock and public tenders, with immediate dispatch from the warehouse.
2. Technical Explanation
This extension line acts as a single-lumen extension between the syringe loaded in the pump and the patient’s catheter or vascular access, extending the circuit without the need to disconnect the infusion. Its flexible tubing with a gauge of Ø1.5 x 2.5 mm (1.5 mm internal diameter and 2.5 mm external diameter) provides a stable and continuous flow, suitable for the low and medium flow rates typical of syringe pumps, with low resistance to drug passage.
The rotating Luer Lock (swivel nut) on both ends secures the connection with a thread, preventing accidental disconnections, while the free rotation of the collar prevents the tubing from twisting or kinking when the patient or pump moves. Being BPA-free and single-use, it is suitable for the administration of drugs and solutions in demanding clinical environments, minimising the risk of material interactions.
3. Technical Specifications
| Reference | PMFMPS200F |
| Product type | 1-way infusion extension line for syringe pump |
| Length | 200 cm |
| Tube diameter | Ø1.5 x 2.5 mm (internal Ø 1.5 mm / external Ø 2.5 mm) |
| Proximal connector | Female Luer Lock (rotating collar) |
| Distal connector | Male Luer Lock (rotating collar) |
| Material | Medical-grade PVC |
| Composition | BPA-free |
| Approximate priming volume | ≈ 3.5 ml (estimated based on internal diameter and length; manufacturer does not declare official value) |
| Maximum pressure | Not declared by the manufacturer |
| Compatibility | Syringe pumps and standard syringes with Luer Lock connection |
| Use | Single-use (disposable) |
| Sterility | Not specified (consult technical department) |
| Presentation | Box of 125 units |
4. Equivalences and Cross-References
Exact reference equivalent (same series): within the Cahnos catalogue, the PMFMPS_F series shares material (BPA-free PVC), internal diameter (Ø1.5 mm) and connector (male/female rotating Luer Lock), differing only in length: PMFMPS25F (25 cm), PMFMPS50F (50 cm), PMFMPS100F (100 cm), PMFMPS150F (150 cm) and PMFMPS200F (200 cm). They are interchangeable in performance, choosing the length according to the application.
Comparable by category (not interchangeable 1:1): the PMFMPS_D1F series (e.g. PMFMPS200D1F) retains the rotating Luer Lock but with Ø1 x 2.5 mm tubing (lower residual volume); the PMFPS_F series offers a fixed Luer Lock; and the PMFPS_PE001 series uses PVC-free polyethylene. In the general market, syringe pump lines from other manufacturers differ at least in diameter or connector configuration:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| B. Braun | Original Perfusor® Line PVC, 200 cm | 8722862 | Comparable by category, not interchangeable 1:1 | PVC, male/female Luer Lock; differs in Ø 1.5 x 2.7 mm and priming volume 3.61 ml; max. pressure 2.0 bar; box of 100 units |
| B. Braun | Original Perfusor® Line PVC (small tubing), 200 cm | 8745919N | Comparable by category, not interchangeable 1:1 | PVC, internal diameter 0.9 mm with external Ø 1.9 mm; priming 1.42 ml; max. pressure 2.0 bar |
| Fresenius Kabi | Injectomat® Line PVC, 200 cm | 9014342 (indicative, verify) | Comparable by category, not interchangeable 1:1 | Syringe pump line with Luer Lock connector; verify diameter and connectors in official data sheet |
| Vygon | LectroCath PE, 200 cm | 1155.20 | Comparable by category, not interchangeable 1:1 | Polyethylene with Ø 1.0 x 2.0 mm and priming ~2.0 ml; not PVC |
| Vygon | PVC Extension Tube Male/Female Luer Lock, 200 cm | 000220200 | Comparable by category, not interchangeable 1:1 | PVC but Ø 2.5 x 4.0 mm (larger diameter); not a microbore line for syringe pump |
| Codan | Syringe Pump Extension Set (microbore) | 71.4356 (100 cm) | Comparable by category, not interchangeable 1:1 | PVC, internal diameter 0.9 mm, micro male/female Luer Lock; verify length and clamp |
Not verified: there is no cross-reference equivalence table validated by the manufacturer for this reference against other brands; the above comparisons are provided for guidance and must be confirmed with the technical department of Cahnos before establishing substitution in public procurement specifications or care protocols.
5. Selection tips and variants of interest
Length: the 200 cm version is ideal when the pump needs to be placed away from the patient or to facilitate mobility in beds, chairs and transfers. For shorter circuits, consider the 25, 50, 100 or 150 cm versions of the same PMFMPS_F series.
Diameter: the Ø1.5 x 2.5 mm tubing provides good flow for standard infusions; if your protocol requires minimising residual volume and priming (high-risk medication), consider the D1F series with Ø1 x 2.5 mm tubing (e.g. PMFMPS200D1F).
Connector: the rotating collar facilitates threading without transmitting torsion to the tubing; if you prefer a rigid fixation without rotation, consult the versions with fixed Luer Lock (PMFPS_F series, e.g. PMFPS200F).
Material: if your protocol requires avoiding PVC or plasticisers, consider the polyethylene lines (PMFPS_PE001 series, e.g. PMFPS200PE001) or the opaque PVC versions for light-sensitive drugs (PMFTJPS200F).
Compatibility: always check the pump, syringe and three-way stopcocks in the circuit; this extension line is compatible with standard syringes and syringe pumps with Luer Lock connection on the market. For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples.