Single-Use Continuous Flow Elastomeric Infusion Pump ELASPUMP® 200 ml (8 ml/hour) = (1 day + 1 hour) | Ref. 093004/7

24,75 €

Elastomeric infusion pump ELASPUMP® 200 ml, single-use and continuous flow calibrated at the factory at 8 ml/hour, with an approximate autonomy of 1 day + 1 hour at full volume. It works without batteries, without electronics and without maintenance: its silicone elastomer in a hermetic, rigid and transparent casing drives the drug at a constant and safe flow rate via intravenous, arterial, epidural and subcutaneous routes. Indicated for chemotherapy, pain therapy, antiviral and antibiotic treatments. Free of DEHP, PVC and latex; includes one-way filling valve, male luer-lock connector with hydrophobic filter and in-line particle filter. Ref. 093004/7.

Pedido mínimo de 60 unidades por condiciones del fabricante.

International shipping. Import duties and taxes are payable by the recipient.

Reference
093004/7

Description

1. Continuous, safe infusion without electronic equipment

The Elastomeric Infusion Pump ELASPUMP® 200 ml (Ref. 093004/7) is the ideal solution for the continuous and controlled administration of medications in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free of DEHP, PVC and latex, which allows drugs to be infused at a fixed calibrated flow rate of 8 ml/hour without relying on electronic pumps, batteries or maintenance, with a very competitive cost per treatment and no risk of cross-contamination between patients. Its ease of use makes it a practical option for both healthcare professionals and patients themselves, especially in medium-rate infusion regimens.

2. Technical description and operating principle

The ELASPUMP® pump works through the elastic recovery pressure of a silicone elastomer housed inside a hermetic, rigid and transparent casing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. This pressure drives the medication through the tubular system at a constant flow rate calibrated at the factory of 8 ml/hour, which translates into an approximate autonomy of 1 day + 1 hour (25 hours) with the full 200 ml volume. Its technical features include:

  • Silicone elastomer: encapsulated in a hermetic, rigid and transparent casing, leak-free and with visual level inspection.
  • One-way filling valve: closed-circuit with flat bottom, compatible with a standard syringe, which facilitates elastomer filling.
  • Hydrophobic filter: on the male luer-lock connector cap; allows priming the line without removing the cap and preserves internal sterility until actual use.
  • In-line particle filter: retains impurities and guarantees the purity of the administered drug.
  • Removable sliding clamp: easy to remove when necessary.
  • Colour-coded label: with flow rate printed for quick and immediate identification of the flow.
  • Patient label: designed for easy personalisation of the treatment.
  • Full traceability: variable data and product code printed on the outer casing and on the pump body.

3. Technical Specifications

Below are the main technical specifications of the ELASPUMP® 200 ml continuous flow pump at 8 ml/hour:

Characteristic Specification
Brand ELASPUMP®
Reference 093004/7
Capacity 200 ml
Flow type Fixed continuous (factory-calibrated)
Infusion flow rate 8 ml/hora
Approximate duration 1 day + 1 hour (approx. 25 hours at full volume)
Drive mechanism Silicone elastomer in rigid and transparent casing
Filling system Closed-circuit one-way valve, compatible with standard syringe
Connection Male Luer-Lock connector with cap and hydrophobic filter
Filtration Hydrophobic filter + in-line particle filter
Routes of administration Intravenous, arterial, epidural and subcutaneous
Clinical indications Chemotherapy, pain therapy, antiviral and antibiotic treatments
Power supply Does not require battery or electrical power source
Use Single-use, sterile
Composition DEHP-free, PVC-free, latex-free

Indicative infusion duration according to flow rate (200 ml volume):

Flow rate Approximate duration
2 ml/hora Approx. 4 days + 4 hours
4 ml/hora Approx. 2 days + 2 hours
6 ml/hora Approx. 1 day + 9 hours
8 ml/hour (current product) Approx. 1 day + 1 hour (25 hours)
10 ml/hora Approx. 20 hours
12 ml/hora Approx. 16 hours + 40 minutes
14 ml/hora Approx. 14 hours + 20 minutes

Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.

4. Equivalences and Cross-References

The ELASPUMP® 200 ml continuous flow (Ref. 093004/7) belongs to the range of continuous flow elastomeric pumps of the ELASPUMP® family and is complementary to the following references available at Cahnos:

Reference Capacity Flow rate Approximate duration
093001/4 60 ml 2 ml/hora 1 day + 6 hours
093002/5/B 100 ml 4 ml/hora 1 day + 1 hour
093004/7 (current product) 200 ml 8 ml/hora 1 day + 1 hour
093005/8/B 275 ml 10 ml/hora 1 day + 3 hours (with UV protection)

Furthermore, within the same 200 ml capacity, it offers DEHP-free variable flow variants: 093004/M1 (4 speeds: 2-5-7-12 ml/h), 093004/M2 (8-speed selector 0-7) and 093004/M3 (8 speeds: 0-2-4-6-8-10-12-14 ml/h). Due to its 200 ml capacity, its pressurised elastomer system with luer-lock connector, hydrophobic filter and fixed calibrated flow rate, this device is comparable to disposable continuous flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, being interchangeable in most clinical protocols for continuous infusion and patient-controlled analgesia (PCA). Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.

5. Selection tips and variants of interest

  • Volume and duration: the 200 ml version at 8 ml/hour is ideal for medium-duration therapies of approximately 25 hours at full volume. For shorter regimens, 60 ml and 100 ml versions are available; for longer therapies, the 275 ml version.
  • Required flow rate: if your protocol is fixed and medium flow, this 8 ml/hour version offers an excellent cost-benefit ratio. If you need to adjust the speed during treatment, consider the 200 ml variable flow variants (Refs. 093004/M1, 093004/M2 and 093004/M3).
  • Photosensitive drugs: for light-sensitive medications, choose the ELASPUMP® versions with UV protection (for example, Ref. 093005/8/B of 275 ml at 10 ml/hour).
  • Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
  • Purchase conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.

Additional information

Brand

ELASPUMP®

Reference

093004/7

Duration

1 day + 1 hour (approx. 25 hours)

Flow type

Fixed continuous, factory-calibrated

Drive mechanism

Silicone elastomer in a rigid, transparent hermetic housing

Filling system

Closed-circuit unidirectional valve compatible with standard syringe

Connection

Male Luer-Lock connector with cap and hydrophobic filter

Filtration

Hydrophobic filter + in-line particle filter

Routes of administration

Intravenous, arterial, epidural and subcutaneous

Indications

Chemotherapy, pain therapy, antiviral and antibiotic

Power supply

Does not require battery or electrical power source

Use

Single-use, sterile

Composition

DEHP-free, PVC-free, latex-free

Sterilisation

Sterile (single-use)

Capacidad

200 ml

Flujo por hora

8 ml/hora, 8 ml / hour = 1 day + 1 hour