Description
1. Introduction
The 1-way 100 cm infusion extension line (Ref. PMFFL100F) is the essential replacement accessory for completing infusion circuits in hospitalisation, emergency, ICU, oncology, paediatrics and home care services. With its fixed male/female Luer Lock ends and its flexible medical-grade PVC tube Ø2.5×4.1 mm, BPA-free, it allows the distance between the medication point and the patient’s vascular access to be extended with total safety, maintaining a leak-tight, rigid and leak-free connection throughout the therapy.
It is supplied in a box of 125 units, making it the cost-effective and reliable replacement solution for hospital purchases, ward stock and public tenders, with immediate availability from warehouse.
2. Technical Explanation
This extension line acts as a single-lumen extension line: it is inserted between the infusion set (drip chamber, volumetric pump or syringe) and the catheter or patient’s vascular access, allowing the administration point to be moved away, the lines to be organised and sequential injections to be performed without disconnecting the circuit. Its Ø2.5×4.1 mm bore tube (2.5 mm internal diameter) offers a generous flow rate and low resistance to fluid passage, suitable for gravity fluid therapy, drug infusions and administration of solutions at medium and high flow rates.
The fixed Luer Lock connectors present at both ends (distal male and proximal female) ensure a rigid threaded coupling, with no moving parts that could loosen, preventing accidental disconnections and maintaining leak-tightness even during prolonged therapies or patient transfers. Being BPA-free, it minimises the risk of material interactions with the administered drugs. It is a single-use (disposable) device, in line with the standard use of this type of line.
3. Technical Specifications
| Reference | PMFFL100F |
| Product type | 1-way infusion extension line |
| Length | 100 cm |
| Tube diameter | Ø2.5 x 4.1 mm (internal Ø 2.5 mm / external Ø 4.1 mm) |
| Proximal connector | Female Luer Lock (fixed) |
| Distal connector | Male Luer Lock (fixed) |
| Material | Medical-grade PVC |
| Composition | BPA-free |
| Approximate residual volume | ≈ 5 ml (estimated based on internal diameter and length; the manufacturer does not declare an official value) |
| Maximum pressure | Not declared by the manufacturer (consult technical department) |
| Compatibility | Infusion equipment, three-way stopcocks, catheters and accessories with standard Luer Lock connection |
| Use | Single-use (disposable) |
| Sterility | Not specified (consult technical department) |
| Presentation | Box of 125 units |
4. Equivalences and Cross-References
There is no cross-reference equivalence table validated by the manufacturer for this reference against other brands; the following comparisons are offered for guidance only (comparable by category) and must be confirmed with the Cahnos technical department before use in tenders or stock replacement. Field by field, the length (100 cm), the male/female Luer Lock connection and the internal diameter (2.5 mm) match standard extension lines on the market, but the external diameter, material and residual volume declared by other manufacturers differ, so they are not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Cahnos | PVC extension line 100 cm fixed Luer Lock Ø2.5×4.1 | PMFFL100F (current product) | Reference product | BPA-free PVC, Ø2.5 x 4.1 mm, fixed nut, box of 125 units |
| Vygon | Lectroflex, three-layer extension tube (PVC/EVA/PE), 100 cm | 220,100 (official Vygon catalogue) | Comparable by category, not interchangeable 1:1 | Internal Ø 2.5 mm and external 4.0 mm, priming volume 5.2 ml, tested at 10 kg/cm², pack of 25 units |
| B. Braun | Original Perfusor® Line PVC Standard, 100 cm | 0009483H (official B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | Syringe pump line, Ø1.5 x 2.7 mm, priming volume 1.84 ml, max. pressure 2 bar, pack of 100 units |
| B. Braun | Original Perfusor® Line PE, Luer Lock, 100 cm | 8255067 (official B. Braun catalogue) | Comparable by category, not interchangeable 1:1 | Polyethylene (not PVC), Ø1.0 x 2.0 mm, priming volume 0.88 ml, max. pressure 2 bar, pack of 100 units |
| Codan | Syringe Pump Extension Set, 100 cm (microbore) | 71.4356 (authorised distributor) | Comparable by category, not interchangeable 1:1 | PVC, internal diameter 0.9 mm, micro male/female Luer Lock, sliding clamp; specific line for syringe pump |
| BD CareFusion | Extension line for infusion equipment, 100 cm | D1-100 (reference seen at distributors; confirm with manufacturer) | Pending confirmation | PVC, internal Ø 3.0 mm and external 4.1 mm, max. pressure 2 bar, DEHP- and latex-free; verify official BD reference |
Within the Cahnos catalogue, the PMFFL_F series shares material (BPA-free PVC), diameter (Ø2.5×4.1 mm) and connector (fixed male/female Luer Lock), differing only in length: PMFFL10F (10 cm), PMFFL50F (50 cm), PMFFL100F (100 cm), PMFFL150F (150 cm, SKU 0322034) and PMFFL200F (200 cm). They are interchangeable in performance by choosing the length according to the application. The PMFML_F series maintains the same tube and material but with a movable nut Luer Lock (e.g. PMFML100F for 100 cm). Not verified: there is no cross-reference table validated by the manufacturer against other brands; it is recommended to consult the Cahnos technical department before fixing the substitution in public procurement specifications or care protocols.
5. Selection tips and variants of interest
- Length: the 100 cm version offers a good balance between patient mobility and contained residual volume. For shorter circuits, consider the 10 or 50 cm versions; for greater distance, the 150 or 200 cm versions of the same PMFFL_F series.
- Connector: the fixed nut provides a rigid fixation without rotation; if you prefer a thread that does not transmit torsion to the tube during patient movements, consult the series with movable Luer Lock (PMFML100F).
- Residual volume: if your protocol requires minimising the priming volume and drug residue (high-risk medication), consider microbore lines; for high fluid therapy flow rates, this extension line with 2.5 mm internal diameter is the appropriate option.
- Compatibility: always verify the infusion set, three-way stopcocks and the catheter of the circuit; this extension line is compatible with standard Luer Lock connection accessories on the market.
- Accessories: combine it with three-way stopcocks, non-return valves, obturators and other infusion accessories from the Cahnos catalogue to adapt the circuit to each therapy.
- For tenders or replacement of references from other manufacturers, contact our technical-commercial department to validate exact compatibility and request samples before institutional purchase.





Reviews