We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Single-Use Elastomeric Infusion Pump with Continuous Flow ELASPUMP® with UV Protection, 200 ml (1.5 ml/hour ≈ 5 Days and 13 Hours) | Ref. 093004/3/B

33,00 €

Elastomeric infusion pump ELASPUMP® of 200 ml with UV protection and continuous flow of 1.5 ml/hour (approximate duration of 5 days and 13 hours at full volume), single-use and sterile, designed for photosensitive drugs. No batteries or electronics: its silicone elastomer drives the medication at a constant, calibrated flow rate via intravenous, arterial, epidural and subcutaneous routes. Indicated for chemotherapy, pain therapy, antiviral and antibiotic treatments, especially for prolonged infusions and home hospitalisation. Free from DEHP, PVC and latex, it incorporates a one-way filling valve, male luer-lock connector with hydrophobic filter and in-line particle filter. Reference 093004/3/B, available at Cahnos.

Pedido mínimo de 60 unidades por condiciones del fabricante.

International shipping. Import duties and taxes are payable by the recipient.

Reference
093004/3/B

Description

1. Continuous, safe infusion without electronic equipment

The 200 ml elastomeric infusion pump ELASPUMP® with UV protection (Ref. 093004/3/B) is the ideal solution for the constant and controlled administration of medications in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free from DEHP, PVC and latex, which allows drugs to be infused at a calibrated flow rate of 1.5 ml/hour without relying on electronic pumps, batteries or maintenance, with a very competitive cost per treatment.

With an approximate autonomy of 5 days and 13 hours at full volume, it is the longest-lasting variant in the ELASPUMP® 200 ml range with UV protection, especially recommended for prolonged therapies with photosensitive medications, common in oncology treatments. Its ease of use makes it a practical option for both healthcare professionals and patients themselves.

2. Technical description and operating principle

The ELASPUMP® pump works through the elastic recovery pressure of a silicone elastomer housed inside a hermetic, rigid and transparent casing, which prevents accidental leaks and allows visual inspection of the drug level from the outside. This pressure drives the medication through the tubular system at a constant, factory-calibrated flow rate of 1.5 ml/hour, resulting in an approximate autonomy of 5 days and 13 hours (about 133 hours) with the full 200 ml volume.

  • Silicone elastomer: encapsulated in a hermetic, rigid and transparent casing with UV protection, leak-free and with visual level inspection.
  • One-way filling valve: closed-circuit with a flat bottom, which facilitates filling the elastomer using a standard syringe.
  • Hydrophobic filter: on the male luer-lock connector cap, which allows priming the line without removing the cap and preserves internal sterility until actual use.
  • In-line particle filter: integrated into the circuit, retains impurities and guarantees the purity of the administered drug.
  • Removable sliding clamp: easy to remove if necessary.
  • Colour-coded label with flow rate printing: for quick and unambiguous identification of the flow.
  • Patient label: designed for easy personalisation of the treatment.
  • Full traceability: variable data and product code printed on both the external casing and the pump body.

3. Technical Specifications

Characteristic Specification
Brand ELASPUMP®
Reference 093004/3/B
Capacity 200 ml
Flow type Fixed continuous (factory-calibrated)
Infusion flow rate 1.5 ml/hora
Approximate duration ≈ 5 days + 13 hours (approx. 133 hours at full volume)
Drive mechanism Silicone elastomer in rigid and transparent casing
Filling system Closed-circuit one-way valve, compatible with standard syringe
Connection Male Luer-lock with cap and hydrophobic filter
Filtration Hydrophobic filter + in-line particle filter
Protection UV protection for photosensitive drugs
Routes of administration Intravenous, arterial, epidural and subcutaneous
Clinical indications Chemotherapy, pain therapy, antiviral and antibiotic treatments
Power supply Does not require battery or electrical power source
Use Single-use, sterile
Composition DEHP-free, PVC-free, latex-free

Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and the characteristics of the drug.

3.1. Indicative infusion duration (200 ml)

Flow rate Approximate duration
1.5 ml/hora 5 days + 13 hours (approx. 133 hours) – current product
2.5 ml/hora 3 days + 8 hours (approx. 80 hours)
4 ml/hora 2 days + 2 hours (approx. 50 hours)
5 ml/hora 1 day + 16 hours (approx. 40 hours)
8 ml/hora 1 day + 1 hour (approx. 25 hours)
10 ml/hora 0 days + 20 hours (approx. 20 hours)

3.2. ELASPUMP® continuous flow range with UV protection

Reference Capacity Flow rate Approximate duration
093002/5/B 100 ml 4 ml/hora 1 day + 1 hour
093004/3/B (current product) 200 ml 1.5 ml/hora 5 days + 13 hours
093004/41/B 200 ml 2.5 ml/hora 3 days + 8 hours
093004/5/B 200 ml 4 ml/hora 2 days + 2 hours
093004/6/B 200 ml 5 ml/hora 1 day + 16 hours
093004/7/B 200 ml 8 ml/hora 1 day + 1 hour
093004/8/B 200 ml 10 ml/hora 0 days + 20 hours
093005/8/B 275 ml 10 ml/hora 1 day + 3 hours

4. Equivalences and Cross-References

The 200 ml ELASPUMP® with UV protection (Ref. 093004/3/B) belongs to the family of ELASPUMP® continuous flow elastomeric pumps and is complementary to the following references available at Cahnos:

  • 093004/41/B: ELASPUMP® 200 ml with UV protection (2.5 ml/hour ≈ 3 days + 8 hours), same technology and capacity with a higher flow rate.
  • 093004/5/B: ELASPUMP® 200 ml with UV protection (4 ml/hour ≈ 2 days + 2 hours).
  • 093004/6/B: ELASPUMP® 200 ml with UV protection (5 ml/hour ≈ 1 day + 16 hours).
  • 093004/7/B: ELASPUMP® 200 ml with UV protection (8 ml/hour ≈ 1 day + 1 hour).
  • 093004/8/B: ELASPUMP® 200 ml with UV protection (10 ml/hour ≈ 20 hours), for faster infusions.
  • 093002/5/B: ELASPUMP® 100 ml with UV protection (4 ml/hour ≈ 1 day + 1 hour), for smaller volumes.
  • 093005/8/B: ELASPUMP® 275 ml with UV protection (10 ml/hour ≈ 1 day + 3 hours), for therapies with larger volume.
  • 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/hour ≈ 1 day + 6 hours).
  • 093004/M1 · M2 · M3: ELASPUMP® 200 ml variable flow (4 and 8 speeds), DEHP-free, for protocols with adjustable flow rate.

Due to its 200 ml capacity, its pressurised elastomer system with luer-lock connector, hydrophobic filter and fixed factory-calibrated flow rate, this device is comparable to disposable continuous flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, being interchangeable in most continuous infusion clinical protocols. Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.

5. Selection tips and variants of interest

  • Volume and duration: the 200 ml version at 1.5 ml/hour is ideal for prolonged therapies of approximately 5 days and 13 hours. For shorter regimens, higher flow rates of 200 ml are available (2.5, 4, 5, 8 and 10 ml/hour), and for smaller or larger volumes, the 60-100 ml and 275 ml versions in the range.
  • Required flow rate: if your protocol is fixed, this continuous flow version offers the best cost-benefit ratio. If you need to adjust the speed during treatment, consider the 200 ml variable flow versions (Refs. 093004/M1, 093004/M2 and 093004/M3).
  • Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093002/5/B, 093004/3/B, 093004/41/B, 093004/5/B, 093004/6/B, 093004/7/B, 093004/8/B and 093005/8/B).
  • Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
  • Purchase conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.

Additional information

Brand

ELASPUMP®

Reference

093004/3/B

Infusion flow rate

1.5 ml/hora

Approximate duration

5 days + 13 hours (approx. 133 hours)

Flow type

Fixed continuous, factory-calibrated

Drive mechanism

Silicone elastomer in rigid and transparent casing

Connection

Male Luer-lock with cap and hydrophobic filter

Filtration

Hydrophobic filter + in-line particle filter

Protection

UV protection for photosensitive drugs

Administration routes

Intravenous, arterial, epidural and subcutaneous

Indications

Chemotherapy, pain therapy, antiviral and antibiotic treatments

Power supply

No battery or power source

Use

Single-use, sterile

Composition

DEHP-free, PVC-free, latex-free

Sterilisation

Sterilised (single-use)

Capacidad

200 ml

Flujo por hora

1.5 ml / hour = 5 Days + 13 Hours

Reviews

There are no reviews yet.

Be the first to review “Single-Use Elastomeric Infusion Pump with Continuous Flow ELASPUMP® with UV Protection, 200 ml (1.5 ml/hour ≈ 5 Days and 13 Hours) | Ref. 093004/3/B”

Your email address will not be published. Required fields are marked *