Description
1. Commercial Introduction
The ELASPUMP® elastomeric infusion pump of 100 ml with UV protection (Ref. 093002/7/B) is the ideal solution for the constant and controlled administration of photosensitive medications in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free of DEHP, PVC and latex, which allows drugs to be infused at a calibrated flow rate of 8 ml/hour without relying on electronic pumps, batteries or maintenance, with a very competitive cost per treatment and no risk of cross-contamination between patients.
2. Technical description and operating principle
The ELASPUMP® pump operates through the elastic recovery pressure of a silicone elastomer housed inside a hermetic, rigid and transparent casing, which prevents accidental leaks and allows visual inspection of the drug level from the outside. This pressure drives the medication through the tubular system at a constant flow rate calibrated at the factory of 8 ml/hour, resulting in an approximate autonomy of 0 days + 12 hours with the full volume of 100 ml. The integrated UV protection preserves the stability of the drug throughout the infusion period.
- Silicone elastomer: encapsulated in a hermetic, rigid and transparent casing with UV protection, leak-free and with visual level inspection.
- One-way filling valve: closed-circuit with flat bottom, compatible with standard syringe.
- Hydrophobic filter: on the male luer-lock connector cap, allows priming of the line without removing the cap and preserves internal sterility until actual use.
- In-line particle filter: retains impurities and guarantees the purity of the administered drug.
- Removable sliding clamp: easy to remove when necessary.
- Colour-coded label: flow rate printed for quick and immediate identification of the flow.
- Patient label: designed for easy personalisation of the treatment.
- Full traceability: variable data and product code printed on the external casing and on the pump body.
3. Technical Specifications
| Characteristic | Specification |
| Brand | ELASPUMP® |
| Reference | 093002/7/B |
| Capacity | 100 ml |
| Flow type | Fixed continuous (factory-calibrated) |
| Infusion flow rate | 8 ml/hora |
| Approximate duration | 0 days + 12 hours (approx. 12 hours at full volume) |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-lock with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Protection | UV protection for photosensitive drugs |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Chemotherapy, pain therapy, antiviral and antibiotic treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile |
| Composition | DEHP-free, PVC-free, latex-free |
Indicative values calculated at full volume; actual duration may vary slightly depending on conditions of use and the characteristics of the drug.
Indicative duration of the ELASPUMP® continuous flow range with UV protection
| Reference | Capacity | Flow rate | Approximate duration |
| 093002/5/B | 100 ml | 4 ml/hora | 1 day + 1 hour |
| 093002/7/B (current product) | 100 ml | 8 ml/hora | 0 days + 12 hours |
| 093002/8/B | 100 ml | 10 ml/hora | 0 days + 10 hours |
| 093004/7/B | 200 ml | 8 ml/hora | 1 day + 1 hour |
| 093005/7/B | 275 ml | 8 ml/hora | 1 day + 10 hours |
Indicative values calculated at full volume; actual duration may vary slightly depending on conditions of use and the characteristics of the drug.
4. Equivalences and Cross-References
The ELASPUMP® 100 ml with UV protection (Ref. 093002/7/B) belongs to the range of continuous flow elastomeric pumps of the ELASPUMP® family, being complementary and equivalent in performance to the following references available at Cahnos:
- 093002/5/B: ELASPUMP® 100 ml with UV protection, continuous flow of 4 ml/hour (1 day + 1 hour), same capacity with lower flow rate.
- 093002/8/B: ELASPUMP® 100 ml with UV protection, continuous flow of 10 ml/hour (0 days + 10 hours), same capacity with higher flow rate.
- 093005/7/B: ELASPUMP® 275 ml with UV protection, continuous flow of 8 ml/hour (1 day + 10 hours), same flow rate with larger volume.
- 093004/7/B: ELASPUMP® 200 ml with UV protection, continuous flow of 8 ml/hour (1 day + 1 hour), same flow rate with larger volume.
- 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/hour = 1 day + 6 hours), for smaller volumes.
- 093002/M1 · M3: ELASPUMP® 100 ml variable flow (4 and 8 speeds), DEHP-free, for protocols with adjustable flow rate.
Due to its 100 ml capacity, its pressurised elastomer system with luer-lock connector, hydrophobic filter, calibrated fixed flow rate and UV protection, this device is comparable to disposable continuous flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, being interchangeable in most clinical protocols for continuous infusion and patient-controlled analgesia (PCA). Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.
5. Selection tips and variants of interest
- Volume to infuse: the 100 ml version at 8 ml/hour is ideal for short-duration therapies (approx. 12 hours at full volume). For smaller volumes, the 60 ml version is available (Ref. 093001/4) and for longer therapies, the 200 ml and 275 ml versions with UV protection (Refs. 093004/7/B and 093005/7/B).
- Required flow rate: if your protocol is fixed, this continuous flow version at 8 ml/hour offers the best cost-benefit ratio. If you need to adjust the speed during treatment, consider the 100 ml variable flow versions (Refs. 093002/M1 and 093002/M3).
- Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093002/5/B, 093002/7/B, 093002/8/B, 093004/7/B and 093005/7/B).
- Accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.
- Purchase conditions: contact our technical-commercial department to request samples, technical data sheets or special conditions for tenders and hospital purchases.




Reviews
There are no reviews yet.