We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Single-Use Continuous Flow Elastomeric Infusion Pump ELASPUMP® with UV Protection, 275 ml (4 ml/hour ≈ 2 Days + 21 Hours) | Ref. 093005/5/B

33,00 €

Elastomeric pump ELASPUMP® 275 ml with UV protection and fixed calibrated flow rate of 4 ml/hour: infuses the full volume in approximately 2 days + 21 hours. Single-use, sterile and free of DEHP, PVC and latex, without batteries or maintenance. Ideal for continuous administration of photosensitive medications by intravenous, arterial, epidural and subcutaneous routes in chemotherapy, pain therapy, antiviral and antibiotic treatments. Incorporates silicone elastomer in transparent housing, one-way filling valve, male luer-lock connector with hydrophobic filter and in-line particle filter. Hospitals, clinics and home hospitalisation.

Pedido mínimo de 60 unidades por condiciones del fabricante.

International shipping. Import duties and taxes are payable by the recipient.

Reference
093005/5/B

Description

Continuous, safe infusion without electronic equipment

The 275 ml elastomeric pump ELASPUMP® with UV protection is the ideal solution for the continuous administration of drugs in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free of DEHP, PVC and latex, which allows medication to be administered constantly and reliably without the need for electronic pumps, batteries or maintenance, at a very competitive cost per treatment.

Its UV protection makes it especially recommended for photosensitive medications, common in oncology treatments, and its flow rate of 4 ml/hour offers an approximate duration of 2 days and 21 hours, ideal for medium and long-duration regimens.

Technical description and operating principle

The ELASPUMP® pump works through the elastic recovery pressure of a silicone elastomer contained inside a hermetic, rigid and transparent housing, which prevents accidental leaks and allows visual inspection of the drug level from the outside without having to open the device. This pressure drives the medication through the tubular system at a constant flow rate calibrated at the factory of 4 ml/hour, which translates into a duration of approximately 2 days + 21 hours with the full volume of 275 ml.

  • Silicone elastomer encapsulated in a hermetic, rigid and transparent housing, with visual inspection of the drug level.
  • Unidirectional closed-circuit filling valve with flat bottom, compatible with a standard syringe.
  • Hydrophobic filter on the male luer-lock connector cap, which allows priming the line without removing the cap, preserving internal sterility until actual use.
  • In-line particle filter that retains impurities and ensures the purity of the administered drug.
  • Removable sliding clamp, easy to remove when necessary.
  • Label with colour code and flow rate printing for immediate identification and quick access to patient data.
  • Patient label for easy personalisation of the treatment.
  • Full traceability: variable data and product code printed on the external casing and on the pump body.

Technical specifications

The main technical specifications of the ELASPUMP® 275 ml pump with UV protection and continuous flow at 4 ml/hour are detailed below:

Characteristic Specification
Brand ELASPUMP®
Capacity 275 ml
Flow type Fixed continuous (factory-calibrated)
Infusion flow rate 4 ml/hora
Approximate duration ≈ 2 days + 21 hours (at full volume)
Drive mechanism Silicone elastomer in rigid and transparent casing
Filling system Closed-circuit one-way valve, compatible with standard syringe
Connection Male Luer-lock with cap and hydrophobic filter
Filtration Hydrophobic filter + in-line particle filter
Protection UV protection for photosensitive drugs
Routes of administration Intravenous, arterial, epidural and subcutaneous
Clinical indications Chemotherapy, pain therapy, antiviral and antibiotic treatments
Power supply Does not require battery or electrical power source
Use Single-use, sterile
Composition DEHP-free, PVC-free, latex-free
Reference 093005/5/B

Indicative values calculated at full volume; actual duration may vary slightly depending on usage conditions and drug characteristics.

Indicative duration of the ELASPUMP® 275 ml range with UV protection:

Reference Flow rate Approximate duration
093005/5/B (current product) 4 ml/h (continuous, UV) 2 days + 21 hours
093005/6/B 5 ml/h (continuous, UV) 2 days + 7 hours
093005/65/B 7 ml/h (continuous, UV) 1 day + 15 hours
093005/7/B 8 ml/h (continuous, UV) 1 day + 10 hours
093005/8/B 10 ml/h (continuous, UV) 1 day + 3 hours
093002/5/B 4 ml/h (continuous, UV, 100 ml) 1 day + 1 hour

Equivalences and cross-references

The ELASPUMP® 275 ml with UV protection and continuous flow at 4 ml/hour (Ref. 093005/5/B) belongs to the family of ELASPUMP® elastomeric pumps with continuous flow and UV protection, being complementary and equivalent in performance to the following references available at Cahnos:

  • 093005/6/B: ELASPUMP® 275 ml with UV protection (5 ml/h = 2 days + 7 hours).
  • 093005/65/B: ELASPUMP® 275 ml with UV protection (7 ml/h = 1 day + 15 hours).
  • 093005/7/B: ELASPUMP® 275 ml with UV protection (8 ml/h = 1 day + 10 hours).
  • 093005/8/B: ELASPUMP® 275 ml with UV protection (10 ml/h = 1 day + 3 hours).
  • 093002/5/B: ELASPUMP® 100 ml with UV protection (4 ml/h = 1 day + 1 hour).

Due to its capacity, its pressurised elastomer system with luer-lock connector, hydrophobic filter, calibrated flow rate and UV protection, this device is comparable to disposable continuous-flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, being interchangeable in most clinical continuous infusion protocols. Consult our technical-commercial team to confirm exact compatibility with your usual reference supplier.

Selection tips and variants of interest

  • Volume to infuse: the 275 ml version is ideal for medium and long-duration therapies (up to 2 days + 21 hours at 4 ml/hour). For smaller volumes, versions of 60 ml (Ref. 093001/4) and 100 ml (Ref. 093002/5/B) are available.
  • Required flow rate: if your protocol is fixed, this continuous flow version at 4 ml/hour offers the maximum duration within the 275 ml UV range. If you need to adjust the speed during treatment, consider the variable flow versions of 275 ml (Refs. 093005/M1, 093005/M2 and 093005/M3).
  • Photosensitive drugs: for light-sensitive medications, always choose the ELASPUMP® versions with UV protection (Refs. 093005/5/B, 093005/6/B, 093005/65/B, 093005/7/B, 093005/8/B and 093002/5/B).
  • Rapid infusions: if you need to administer the volume in a short time, consider the high continuous flow versions of 275 ml (Refs. 093005/125 and 093005/250).
  • Accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.

To request samples, technical data sheets or special conditions for tenders and hospital purchases, contact our technical-commercial department.

Additional information

Brand

ELASPUMP®

Reference

093005/5/B

Flow type

Fixed continuous (factory-calibrated)

Infusion flow rate

4 ml/hora

Approximate duration

2 days + 21 hours (at full volume)

Drive mechanism

Silicone elastomer in rigid and transparent casing

Filling system

Closed-circuit one-way valve, compatible with standard syringe

Connection

Male Luer-lock with cap and hydrophobic filter

Filtration

Hydrophobic filter + in-line particle filter

Protection

UV protection for photosensitive drugs

Routes of administration

Intravenous, arterial, epidural and subcutaneous

Indications

Chemotherapy, pain therapy, antiviral and antibiotic treatments

Power supply

Does not require battery or electrical power source

Use

Single-use, sterile

Composition

DEHP-free, PVC-free, latex-free

Capacidad

275 ml

Flujo por hora

4 ml / hour = 2 days + 21 hours

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Single-Use Continuous Flow Elastomeric Infusion Pump ELASPUMP® with UV Protection, 275 ml (4 ml/hour ≈ 2 Days + 21 Hours) | Ref. 093005/5/B”

Your email address will not be published. Required fields are marked *