Description
1. Commercial Introduction
The Elastomeric Infusion Pump ELASPUMP® 100 ml (Ref. 093002/1) is the ideal solution for the continuous, controlled administration of medications in hospitals, clinics, home hospitalisation units and outpatient care centres. It is a single-use, sterile device free from DEHP, PVC and latex, which delivers drugs at a factory-calibrated flow rate of 0.5 ml/hour without the need for electronic pumps, batteries or maintenance, at a very competitive cost per treatment and with no risk of cross-contamination between patients. With an approximate autonomy of 8 days + 8 hours at full volume, it is the perfect choice for prolonged infusion regimens.
2. Technical description and operating principle
The ELASPUMP® pump operates by means of the elastic recovery pressure of a silicone elastomer contained inside a sealed, rigid, transparent housing that prevents accidental leaks and allows visual inspection of the drug level from the outside without opening the device. This pressure drives the medication through the tubing system at a constant flow rate of 0.5 ml/hour, providing an approximate autonomy of 200 hours with the full 100 ml volume. Its main technical features include:
- Silicone elastomer: in a sealed, rigid, transparent housing, leak-free and with visual level inspection.
- One-way filling valve: closed-circuit with flat bottom, compatible with standard syringe.
- Hydrophobic filter: on the cap of the male luer-lock connector; allows the line to be primed without removing the cap and preserves internal sterility until actual use.
- In-line particle filter: retains impurities and guarantees the purity of the administered drug.
- Removable sliding clamp: easy to remove when necessary.
- Colour-coded label: with flow rate printed for quick and immediate identification of the flow.
- Patient label: designed for easy personalisation of the treatment.
- Full traceability: variable data and product code printed on the outer housing and on the pump body.
3. Technical Specifications
The main technical specifications of the ELASPUMP® 100 ml pump with continuous flow at 0.5 ml/hour are detailed below:
| Characteristic | Specification |
|---|---|
| Brand | ELASPUMP® |
| Reference | 093002/1 |
| Capacity | 100 ml |
| Flow type | Fixed continuous (factory-calibrated) |
| Infusion flow rate | 0.5 ml/hora |
| Approximate duration | 8 days + 8 hours (approx. 200 hours at full volume) |
| Drive mechanism | Silicone elastomer in rigid and transparent casing |
| Filling system | Closed-circuit one-way valve, compatible with standard syringe |
| Connection | Male Luer-Lock connector with cap and hydrophobic filter |
| Filtration | Hydrophobic filter + in-line particle filter |
| Routes of administration | Intravenous, arterial, epidural and subcutaneous |
| Clinical indications | Chemotherapy, pain therapy, antiviral and antibiotic treatments |
| Power supply | Does not require battery or electrical power source |
| Use | Single-use, sterile |
| Composition | DEHP-free, PVC-free, latex-free |
Indicative infusion duration by flow rate (100 ml volume):
| Flow rate | Approximate duration |
|---|---|
| 0.5 ml/hour (current product) | 8 days + 8 hours (approx. 200 hours) |
| 1 ml/hora | 4 days + 4 hours (approx. 100 hours) |
| 2 ml/hora | 2 days + 2 hours (approx. 50 hours) |
| 2.5 ml/hora | 1 day + 16 hours (approx. 40 hours) |
| 4 ml/hora | 1 day + 1 hour (approx. 25 hours) |
| 5 ml/hora | Approx. 20 hours |
| 8 ml/hora | Approx. 12 hours |
| 10 ml/hora | Approx. 10 hours |
ELASPUMP® DEHP-free 100 ml continuous-flow range available at Cahnos:
| Reference | Capacity | Flow rate | Approximate duration |
|---|---|---|---|
| 093002/1 (current product) | 100 ml | 0.5 ml/hora | 8 days + 8 hours |
| 093002/2 | 100 ml | 1 ml/hora | 4 days + 4 hours |
| 093002/3 | 100 ml | 1.5 ml/hora | 2 days + 19 hours |
| 093002/4 | 100 ml | 2 ml/hora | 2 days + 2 hours |
| 093002/41 | 100 ml | 2.5 ml/hora | 1 day + 16 hours |
| 093002/5 | 100 ml | 4 ml/hora | 1 day + 1 hour |
| 093002/6 | 100 ml | 5 ml/hora | Approx. 20 hours |
| 093002/7 | 100 ml | 8 ml/hora | Approx. 12 hours |
| 093002/8 | 100 ml | 10 ml/hora | Approx. 10 hours |
Indicative values calculated at full volume; actual duration may vary slightly depending on conditions of use and the characteristics of the medication.
4. Equivalences and Cross-References
The ELASPUMP® 100 ml continuous-flow pump (Ref. 093002/1) belongs to the ELASPUMP® elastomeric pump family and is complementary to the following references available at Cahnos:
- 093002/1/B: version with UV protection and the same flow rate (100 ml, 0.5 ml/hour = 8 days + 8 hours), recommended for photosensitive medications; direct equivalent of this model in a protected version.
- 093002/2, 093002/3, 093002/4, 093002/41, 093002/5, 093002/6, 093002/7 and 093002/8: DEHP-free 100 ml continuous-flow versions with flow rates from 1 to 10 ml/hour for shorter regimens.
- 093001/4: ELASPUMP® 60 ml continuous flow (2 ml/hour = 1 day + 6 hours), for smaller volumes.
- 093004/2: ELASPUMP® 200 ml continuous flow (1 ml/hour = 8 days + 8 hours), same flow rate with a larger volume.
- 093005/2: ELASPUMP® 275 ml continuous flow (1 ml/hour = 11 days + 11 hours), for very long-duration therapies.
- 093002/M1, 093002/M2 and 093002/M3: DEHP-free 100 ml variable-flow versions for protocols with adjustable flow rate.
With its 100 ml capacity, pressurised elastomer system with luer-lock connector, hydrophobic filter and fixed factory-calibrated flow rate, this device is comparable to disposable continuous-flow elastomeric pumps from other manufacturers used in ambulatory infusion, controlled analgesia and home intravenous therapy, and is interchangeable in most clinical protocols for long-duration continuous infusion. Contact our technical-commercial team to confirm exact compatibility with your usual reference supplier.
5. Selection tips and variants of interest
- Volume and duration: the 100 ml version at 0.5 ml/hour is ideal for prolonged therapies of approximately 8 days and 8 hours, very useful in long-duration ambulatory regimens. For smaller volumes, the 60 ml version (Ref. 093001/4) is available, and for even longer therapies, the 200 ml and 275 ml versions (Refs. 093004/2 and 093005/2).
- Required flow rate: the 0.5 ml/hour model is the lowest flow rate in the 100 ml range, designed for very slow, prolonged regimens. If your protocol requires a higher rate, consider the continuous-flow versions from 1 to 10 ml/hour or the 100 ml variable-flow versions (Refs. 093002/M1, M2 and M3).
- Photosensitive medications: for light-sensitive medications, choose the ELASPUMP® version with UV protection (Ref. 093002/1/B) or the rest of the protected 100, 200 and 275 ml range.
- Recommended accessories: combine the pump with 1-way or 3-way infusion extension lines with stopcock to adapt the system to the patient’s needs.