Description
1. Introduction
The Universal Obturator Plug Ref. OBTMF (SKU: OBTMF) is the reference solution for the temporary sealing of luer systems in medical, hospital and laboratory environments. Its dual-use design allows it to plug both male luer and female luer nozzles interchangeably, simplifying stock: a single reference covers both connection ends. Made from medical-grade polypropylene and BPA-free, it protects the integrity of the contents and prevents contamination during transport, waiting between procedures or preparation of infusion lines.
2. Technical explanation
The universal plug acts as a single-use hermetic sealing cap. Its geometry combines a press-fit zone for the male luer nozzle and a threaded zone that screws onto the female luer nozzle, adapting to the standardised 6% luer cone defined in standards ISO 594-1 and ISO 594-2. In this way, a single piece solves the capping of the two most common connection sexes in infusion lines, extension tubes, three-way stopcocks and catheters. The absence of BPA and latex, together with the use of medical-grade polypropylene, makes it chemically neutral against the fluids it contacts, minimising risks of leaching and adverse reactions.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference | OBTMF |
| Material | Medical-grade polypropylene (PP), BPA-free and latex-free |
| Connection type | Universal: male luer and female luer (dual use) |
| Function | Temporary capping and sealing of luer nozzles |
| Mode of use | One end fits into the male nozzle; the other screws onto the female side |
| Compatibility | Luer and Luer Lock cones at 6% per ISO 594-1 and ISO 594-2 |
| Presentation | Box of 200 units (carton 20 x 200) |
| Use | Single-use |
4. Equivalences and Cross-References
Below are listed the internal references of the same range and the market alternatives located. Important: there is no equivalence table validated by the manufacturer for this reference; consult the technical department before using in tendering or product substitution.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Cahnos | Universal Obturator Plug (male/female) | OBTMF | Analysed product | BPA-free polypropylene, box of 200 units |
| Cahnos | Female Luer Lock Obturator Cap | OBTFB | Comparable by category (not 1:1) | Only caps male nozzle; white PP; box of 200 units |
| Cahnos | Male Luer Lock Obturator Plug | OBTMB / OBTMBL / OBTMR / OBTM / OBTM02 / OBTMY02 | Comparable by category (not 1:1) | Only caps female nozzle; ABS or polyethylene depending on variant; different colours for visual coding |
| Cranberry | Male-female Luer Lock sealing cap (red cap) | No verified code | Functional equivalence by category | Sterile polypropylene (EO), box of 100 units; not interchangeable 1:1 (sterility and presentation) |
| B. Braun | Closure caps and mixing accessories (infusion range) | Consult local code | Comparable by category | Verify family, material and presentation in official catalogue |
| Qosina | Luer caps (OEM components) | No validated 1:1 code | Comparable by category | Range aimed at OEM manufacturers; confirm taper and thread |
| Vialta | Male/female Luer Lock plug | No verified code | Functional equivalence by category | Sterile polypropylene (EO), individual packaging; not interchangeable 1:1 |
5. Selection tips and variants of interest
To make the right choice, first verify the sex of the connection to be capped (male or female) and the type of fit (simple luer or luer lock with thread). If both connection ends are present in your service, the universal plug OBTMF reduces inventory by covering both cases with a single reference. If you need visual coding by circuit or service, the range of male plugs from Cahnos offers versions in ABS in different colours (white OBTMB, blue OBTMBL, red OBTMR, polyethylene OBTM, with dot OBTMY02 and PE OBTM02) and the female version OBTFB in white polypropylene. The presentation in a box of 200 units is designed for continuous consumption in hospitals, clinics and distributors; for occasional needs or protocols requiring sterile product, consult our technical department for competitor alternatives before substituting the reference.