Description
1. Commercial Introduction
The neonatal radiant warmer TECH-MED R10MB/W (Ref. TMD2919) is the transportable version of the IR-10 infrared radiator from the MB series, a device designed to provide controlled radiant heat to the newborn in delivery rooms, neonatology units and NICUs. Its design on a wheeled trolley allows it to be moved comfortably to the cot or incubator according to the needs of the service, functioning as a mobile substitute for the open incubator.
With a 700 W infrared quartz lamp, automatic air temperature control and a complete alarm system, it offers the professional a precise, safe and constant thermal supply at the point of care. It is the technical solution for units that need flexibility, mobility and safety in the care of the smallest patient.
2. Technical explanation of the equipment
The radiant warmer works as a heat source by infrared radiation: the 700 W quartz lamp emits heat that is directed onto the neonate, providing a direct and controllable thermal supply without contact. The MB series incorporates a control system with automatic air temperature regulation, with a range of 34 to 38 °C and a precision of ±0.2 °C, in addition to digital temperature measurement with a resolution of 0.1 °C, so that the device adjusts the power autonomously. It also allows manual adjustment of the heating power from 0 to 700 W in 5% increments of the maximum range.
Safety is a cornerstone of the device: it has optical and acoustic alarms for low temperature, excessively high temperature (alarm threshold ±0.8 °C) and sensor failure (ERR). It incorporates a clock for APGAR scoring, with audible and visual signals at 1, 3, 5 and 10 minutes, and a 100 W fluorescent lighting system. It is classified as a class II b medical device (MDD), with class I type BF protection.
3. Technical Specifications
| Reference (SKU) | TMD2919 |
| Brand | TECH-MED (ZTM TECH-MED Sp. z o.o.) |
| Model / family | R10MB/W – MB series (IR-10 MB/W radiator) |
| Set type | Transportable neonatal radiant warmer (infrared radiator on trolley) |
| Temperature control | Automatic air control, range 34–38 °C with precision of ±0.2 °C |
| Temperature measurement | Digital, resolution of 0.1 °C |
| Heating power | Manual adjustment 0–700 W in increments of 5% of the maximum range |
| Infrared lamp | 700 W quartz lamp |
| Lighting | 100 W fluorescent |
| Alarms | Low temperature and excessively high temperature (optical and acoustic), threshold of ±0.8 °C; sensor failure (ERR) |
| APGAR clock | Audible and visual signal at 1, 3, 5 and 10 minutes |
| Protection class | Class I, type BF |
| Article classification | MDD, class II b |
| Width | 700 mm |
| Height | 1900 mm |
| Weight | Approx. 35 kg |
| Wheel diameter | 100 mm |
| Bassinet dimensions | 720 mm × 470 mm |
Available references
| Reference | Description |
|---|---|
| TMD2919 | Neonatal radiant warmer R10MB/W (model R10MB/W) |
4. Equivalences and Cross-References
The manufacturer TECH-MED does not publish a validated equivalence table that allows this reference to be substituted by the specific code of another manufacturer on a 1:1 interchangeable basis. Any comparison between brands must be understood as comparable by category and validated field by field before use in tendering or stock replacement.
| Manufacturer / Brand | Family / Model | Reference | Equivalence level | Observations |
|---|---|---|---|---|
| TECH-MED | R10MB radiant warmer with phototherapy (MB series) | TMD2912 (R10MBF) | Same family (manufacturer variant) | It incorporates a 20 W LED phototherapy lamp for bilirubin instead of the 100 W fluorescent lighting. |
| TECH-MED | Neonatal resuscitation station | SRN-10 | Same neonatal range from the manufacturer | Higher-specification resuscitation equipment (92 kg) with 700 W quartz heater, table and accessories; it is not interchangeable 1:1. |
| GIMA | Infant LED phototherapy lamp on trolley | GM31192 | Comparable by category (neonatal heat/phototherapy) | Independent phototherapy source on trolley; does not provide radiant heat. |
| Dixion | BabyGuard radiant warmers with integrated phototherapy | W-1140 / W-1145 | Comparable by category (not interchangeable 1:1) | Radiant heat systems with integrated LED phototherapy; different configurations and specifications. |
5. Selection tips and variants of interest
Select this R10MB/W radiant warmer when your unit needs a mobile radiant heat source that can be brought close to the cot as an alternative to the open incubator, without the need for phototherapy treatment. The 100 mm wheels and the weight of approximately 35 kg facilitate movement between stations in the room, while the automatic temperature control and integrated APGAR clock make it ideal for resuscitation and thermal comfort of the newborn.
If you also need to treat neonatal jaundice at the same point of care, you may consider the manufacturer’s R10MB variant with LED phototherapy (Ref. TMD2912, model R10MBF) from the same MB series; for a more complete resuscitation setup (table, drawer unit and accessories), consider the SRN-10 resuscitation station from TECH-MED. Always verify the exact model reference, dimensions (700 × 1900 mm), the available height in the room and the electrical compatibility of the equipment before placing the order. For quotations, supply times and tendering needs, contact the technical-commercial department of Cahnos.





Reviews